Literature DB >> 19005768

Noninvasive cardiac output measurement by transthoracic electrical bioimpedence: influence of age and gender.

Talakad N Sathyaprabha1, Cauchy Pradhan, G Rashmi, Kandavel Thennarasu, Trichur R Raju.   

Abstract

BACKGROUND: Thoracic electrical bioimpedance (TEB) as a method of measuring cardiac output (CO) is being explored increasingly over the last two decades, as a non-invasive alternative to the pulmonary artery catheter. The objective of this study was to establish normative data for measurement of CO by TEB and define the effect of age and gender on CO.
METHOD: Stroke volume (SV) of 397 normal individuals (203 men, 194 women) in the age range of 10-77 years was determined using Kubisek and Bernstein formulae by TEB method. Derived cardiac parameters including CO, cardiac index (CI), systemic vascular resistance and resistance index were calculated and analyzed.
RESULTS: We found significant difference in CO among age groups and between gender. CO between Kubicek formula and Bernstein formula correlated well, but their means differed significantly. Cardiac indices peak in the third and seventh decade and were comparable between genders.
CONCLUSION: A comprehensive data set of normalized values expressed as 95% confidence interval and mean +/- SD in different age groups and different gender was possible for cardiac parameters using TEB.

Entities:  

Mesh:

Year:  2008        PMID: 19005768     DOI: 10.1007/s10877-008-9148-6

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  25 in total

1.  Thoracic electrical bioimpedance versus thermodilution in patients post open-heart surgery.

Authors:  P Zácek; P Kunes; E Kobzová; J Dominik
Journal:  Acta Medica (Hradec Kralove)       Date:  1999

2.  A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients.

Authors:  James Dean Sandham; Russell Douglas Hull; Rollin Frederick Brant; Linda Knox; Graham Frederick Pineo; Christopher J Doig; Denny P Laporta; Sidney Viner; Louise Passerini; Hugh Devitt; Ann Kirby; Michael Jacka
Journal:  N Engl J Med       Date:  2003-01-02       Impact factor: 91.245

3.  Reproducibility and comparison of cardiac output measurement by transthoracic bioimpedance and thermodilution methods in critically ill patients.

Authors:  H W Ng; N Coleman; T J Walley; S M Mostafa; A M Breckenridge
Journal:  Clin Intensive Care       Date:  1993

4.  Technical aspects of impedance plethysmography.

Authors:  A C Bhuta; J P Babu; G D Jindal; G B Parulkar
Journal:  J Postgrad Med       Date:  1990-04       Impact factor: 1.476

5.  Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution.

Authors:  C Jewkes; J W Sear; F Verhoeff; D J Sanders; P Foëx
Journal:  Br J Anaesth       Date:  1991-12       Impact factor: 9.166

6.  Simplified calculation of body-surface area.

Authors:  R D Mosteller
Journal:  N Engl J Med       Date:  1987-10-22       Impact factor: 91.245

7.  Impedance plethysmography of thoracic region: impedance cardiography.

Authors:  A K Deshpande; G D Jindal; P M Jagasia; K V Murali; P A Bharadwaj; K I Tahilkar; G B Parulkar
Journal:  J Postgrad Med       Date:  1990-10       Impact factor: 1.476

8.  The accuracy of bioimpedance cardiography in the measurement of cardiac output in comparison with thermodilution method.

Authors:  K L Wong; P C Hou
Journal:  Acta Anaesthesiol Sin       Date:  1996-06

9.  Cardiac output measurement in critical care patients: Thoracic Electrical Bioimpedance versus thermodilution.

Authors:  T V Clancy; K Norman; R Reynolds; D Covington; J G Maxwell
Journal:  J Trauma       Date:  1991-08

10.  Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimation.

Authors:  W C Shoemaker; C C Wo; M H Bishop; P L Appel; J M Van de Water; G R Harrington; X Wang; R S Patil
Journal:  Crit Care Med       Date:  1994-12       Impact factor: 7.598

View more
  6 in total

1.  Cardiac parameters in children recovered from acute illness as measured by electrical cardiometry and comparisons to the literature.

Authors:  Jackson Wong; Michael S D Agus; Garry M Steil
Journal:  J Clin Monit Comput       Date:  2012-10-06       Impact factor: 2.502

2.  Non-invasive measurement of cardiac output in obese children and adolescents: comparison of electrical cardiometry and transthoracic Doppler echocardiography.

Authors:  Ralf Rauch; Eva Welisch; Nathan Lansdell; Elizabeth Burrill; Judy Jones; Tracy Robinson; Dirk Bock; Cheril Clarson; Guido Filler; Kambiz Norozi
Journal:  J Clin Monit Comput       Date:  2012-11-21       Impact factor: 2.502

3.  Derivation of baseline lung impedance in chronic heart failure patients: use for monitoring pulmonary congestion and predicting admissions for decompensation.

Authors:  Michael Shochat; Avraham Shotan; David S Blondheim; Mark Kazatsker; Iris Dahan; Aya Asif; Ilia Shochat; Aaron Frimerman; Yoseph Rozenman; Simcha R Meisel
Journal:  J Clin Monit Comput       Date:  2014-09-06       Impact factor: 2.502

4.  Sex related difference in cardiac output during neonatal transition in term neonates.

Authors:  Nariae Baik-Schneditz; Bernhard Schwaberger; Lukas Mileder; Nina Höller; Alexander Avian; Martin Koestenberger; Berndt Urlesberger; Johann Martensen; Gerhard Pichler
Journal:  Cardiovasc Diagn Ther       Date:  2021-04

5.  Cardiac output assessed by invasive and minimally invasive techniques.

Authors:  Allison J Lee; Jennifer Hochman Cohn; J Sudharma Ranasinghe
Journal:  Anesthesiol Res Pract       Date:  2011-07-06

6.  Evaluation of inert gas rebreathing for determination of cardiac output: influence of age, gender and body size.

Authors:  Jessica E Middlemiss; Alex Cocks; Kaido Paapstel; Kaisa M Maki-Petaja; Ian B Wilkinson; Carmel M McEniery
Journal:  Hypertens Res       Date:  2018-12-18       Impact factor: 3.872

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.