Literature DB >> 10566176

Thoracic electrical bioimpedance versus thermodilution in patients post open-heart surgery.

P Zácek1, P Kunes, E Kobzová, J Dominik.   

Abstract

Thoracic electrical bioimpedance cardiography is a non-invasive, continuous and low-cost method of estimation of cardiac output and other haemodynamic parameters. Though subject to continuous technological refinement controversial opinions exist on its validity in subsets of critically ill patients, patients with heart disease or after cardiac surgery. A comparison study between thermodilution (TD) and bioimpedance (TEB) was performed in 28 patients undergoing elective cardiac surgery (CABG, aortic or mitral valve replacement or combined procedures). 128 pairs of cardiac index estimates at specific time points during 20 hours at the postoperative ICU were evaluated. A poor correlation (r = 0.26, p < 0.05, bias -0.07 l.min-1.m2, precision + 1.1 l.min-1.m-2, 95% limits of agreement -2.27-2.13 l.min-1.m-2) between TD and TEB cannot support the routine use of TEB monitoring in early postoperative period after open-heart surgery. Possible reasons of lack of agreement in this population are discussed. Further studies with technically improved bioimpedance cardiographs will be needed.

Entities:  

Mesh:

Year:  1999        PMID: 10566176

Source DB:  PubMed          Journal:  Acta Medica (Hradec Kralove)        ISSN: 1211-4286


  4 in total

1.  Cardiovascular correlates of insulin resistance in normotensive and hypertensive African Americans.

Authors:  Srividya Kidambi; Jane M Kotchen; Shanthi Krishnaswami; Clarence E Grim; Theodore A Kotchen
Journal:  Metabolism       Date:  2010-09-16       Impact factor: 8.694

2.  Noninvasive cardiac output measurement by transthoracic electrical bioimpedence: influence of age and gender.

Authors:  Talakad N Sathyaprabha; Cauchy Pradhan; G Rashmi; Kandavel Thennarasu; Trichur R Raju
Journal:  J Clin Monit Comput       Date:  2008-11-13       Impact factor: 2.502

3.  Cardiac output assessed by invasive and minimally invasive techniques.

Authors:  Allison J Lee; Jennifer Hochman Cohn; J Sudharma Ranasinghe
Journal:  Anesthesiol Res Pract       Date:  2011-07-06

4.  Comparative study of cardiac output measurement by regional impedance cardiography and thermodilution method in patients undergoing off pump coronary artery bypass graft surgery.

Authors:  Amrita Guha; Dheeraj Arora; Yatin Mehta
Journal:  Ann Card Anaesth       Date:  2022 Jul-Sep
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.