Predicting optical densitometer response as a function of light source characteristics for radiochromic film dosimetry.

L E Reinstein1, G R Gluckman, H I Amols.   

Abstract

Various forms of GAFChromic (GC) film have been used for several years as radiographic media for measuring dose distributions of brachytherapy sources and small radiation fields. In order to optimize the measurement sensitivity and thus improve precision, we describe a method to calculate the dose response curves (net optical density at a give wavelength or spectrum versus absorbed dose) for different densitometer light sources using measured GC film absorption spectra. Comparison with measurements on the latest version of GC film (model MD-55-2) using four types of densitometers [He-Ne laser, broadband (white light) densitometer, and two LED (red-light) filtered densitometers] confirm the accuracy of this predictive model. The linearity and sensitivity of the dose response curves are found to be highly dependent on the light source spectrum. Initial slope is a function of the average weighted absorbance. Early saturation and decreased linearity of the dose response curves are ascribed to the nonuniform transmission of the light source through the GC film. We found that an LED (red-light) source with a narrow bandpass filter centered at 671 nm near the major absorption peak achieves nearly the maximum possible sensitivity (almost four times more sensitive than He-Ne laser, 632.8 nm) and may be suitable for in vivo dosimetry.

Entities:  

Mesh:

Year:  1997        PMID: 9434976     DOI: 10.1118/1.598107

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium.

Authors:  Alexandra Rink; David F Lewis; Sangya Varma; I Alex Vitkin; David A Jaffray
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

2.  Measurement verification of dose distributions in pulsed-dose rate brachytherapy in breast cancer.

Authors:  Patrycja Mantaj; Grzegorz Zwierzchowski
Journal:  Rep Pract Oncol Radiother       Date:  2013-04-12

3.  Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films.

Authors:  Sharifeh A Dini; Rafiq A Koona; John R Ashburn; Ali S Meigoonia
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

4.  Expired EBT3 Films' Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis.

Authors:  Hamad Yahia Abu Mhanna; Ahmad Fairuz Omar; Yasmin Md Radzi; Hanan Fawaz Akhdar; Haytham Al Ewaidat
Journal:  Materials (Basel)       Date:  2022-04-15       Impact factor: 3.748

5.  Suitability of radiochromic films for dosimetry of very-low energy X-rays.

Authors:  Martin A Ebert; Ali H Asad; Salim A Siddiqui
Journal:  J Appl Clin Med Phys       Date:  2009-09-02       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.