Literature DB >> 11420626

Sensitometric comparison of speed group E and F dental radiographic films.

J R Geist1, J W Brand.   

Abstract

OBJECTIVE: To evaluate the sensitometric characteristics of Insight, (Eastman Kodak, Rochester, NY, USA) a new F-speed film, in fresh and depleted processing solutions and compare them with Ektaspeed Plus.
METHODS: Two sets each of Insight (IP) and Ektaspeed Plus (EP) films were exposed to radiation levels ranging from 10.7 to 685.2 microGy. One set of films was processed in fresh chemicals while the other set was processed in solutions that had been used for 5 days to process over 500 radiographs. Unexposed films of both types were processed in both solutions to determine base-plus-fog density. Speed and contrast were measured according to ISO definitions and at other levels of density.
RESULTS: IP was in speed group F as measured at optical density 1 above base-plus-fog when processed under both conditions. It was 25% faster than EP when both were processed in new solutions and 35% faster in the old solutions, permitting a 20-24% reduction in exposure time. The speeds of both film types decreased when processed in used solutions, but the decrease was smaller for IP than for EP. Speeds at other density levels were greater for IP than EP. Contrast as defined by ISO, and over other density ranges, was similar for both films.
CONCLUSIONS: Insight is an F-speed film with a speed at least 25% greater than Ektaspeed Plus. IP is more resistant than Ektaspeed Plus to decreases in speed when processed in used chemicals. Contrast of IP and EP is comparable over several density ranges.

Mesh:

Substances:

Year:  2001        PMID: 11420626     DOI: 10.1038/sj/dmfr/4600595

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  4 in total

1.  Detection of artificial occlusal caries in a phosphor imaging plate system with two types of LCD monitors versus three different films.

Authors:  Mehmet Ilgüy; Semanur Dinçer; Dilhan Ilgüy; Gündüz Bayirli
Journal:  J Digit Imaging       Date:  2008-10-24       Impact factor: 4.056

2.  Evaluation of simulated periodontal defects via various radiographic methods.

Authors:  Ayse Zeynep Zengin; Pinar Sumer; Peruze Celenk
Journal:  Clin Oral Investig       Date:  2015-02-14       Impact factor: 3.573

3.  The evaluation of effect of developer age in the detection of approximal caries using three speed dental x-ray films: an in-vitro study.

Authors:  Vijaylaxmi B Madalli; Rajeshwari G Annigeri; Shrinivas M Basavaraddi
Journal:  J Clin Diagn Res       Date:  2014-03-15

4.  Diagnostic Dental Radiation Risk during Pregnancy: Awareness among General Dentists in Tabriz.

Authors:  Tahmineh Razi; Leila Bazvand; Morteza Ghojazadeh
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-06-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.