Literature DB >> 16296430

Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries.

Elaine Aparecida Félix de Araujo1, Julio Cezar de Melo Castilho, Edmundo Medici Filho, Mari Eli Leonelli de Moraes.   

Abstract

PURPOSE: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films.
METHODS: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve.
RESULTS: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.

Entities:  

Mesh:

Year:  2005        PMID: 16296430

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  4 in total

1.  Detection of artificial occlusal caries in a phosphor imaging plate system with two types of LCD monitors versus three different films.

Authors:  Mehmet Ilgüy; Semanur Dinçer; Dilhan Ilgüy; Gündüz Bayirli
Journal:  J Digit Imaging       Date:  2008-10-24       Impact factor: 4.056

Review 2.  Radiographic modalities for diagnosis of caries in a historical perspective: from film to machine-intelligence supported systems.

Authors:  Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2021-03-04       Impact factor: 3.525

3.  Diagnostic Accuracy of Charge-coupled Device Sensor and Photostimulable Phosphor Plate Receptor in the Detection of External Root Resorption In Vitro.

Authors:  Shirin Sakhdari; Zohreh Khalilak; Elham Najafi; Rezvaneh Cheraghi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2015-03-04

4.  Diagnostic Accuracy of Cone-Beam Computed Tomography and Periapical Radiography in Internal Root Resorption.

Authors:  Zahrasadat Madani; Ehsan Moudi; Ali Bijani; Elham Mahmoudi
Journal:  Iran Endod J       Date:  2015-12-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.