Literature DB >> 11175272

Sensitometric and clinical evaluation of a new F-speed dental X-ray film.

K Syriopoulos1, X L Velders, G C Sanderink, P F van Der Stelt.   

Abstract

OBJECTIVE: To compare the sensitometric properties, diagnostic efficacy and image quality of the InSight (F-speed) and Ektaspeed Plus (E-speed) dental X-ray films (Kodak Eastman Co, Rochester, USA).
METHODS: Characteristic curves were constructed, using manual and automatic processing, in order to compare film speed and average gradient. The diagnostic yield was compared by assessment of endodontic file length. Endodontic files, sizes 10 and 15, were placed at the root apex or 1.5 mm short. The exposure time for the InSight films was 20% lower than that of Ektaspeed Plus. Seven dentists rated the position of file tip using a 5-point confidence scale. ROC data were analysed by means of analysis of variance. The null hypothesis was rejected when P<0.05. In order to compare the image quality, 100 pairs of bitewing radiographs of the left (using Ektaspeed Plus) and the right sides (using InSight) of the same patient were made. Four dentists viewed the radiographs and the data were analysed using Kendall's coefficient of concordance.
RESULTS: InSight was faster than Ektaspeed Plus. It was an E-speed film when processed in manual conditions and an F-speed film when processed automatically. The films had comparable average gradient. No significant difference was found in the diagnostic yield using the two films (P=0.648). Two observers showed a significant preference for Ektaspeed Plus.
CONCLUSIONS: The first results of the new InSight film are promising: the exposure time can be reduced by 20% in comparison with Ektaspeed Plus at no detriment to diagnostic efficacy.

Entities:  

Mesh:

Year:  2001        PMID: 11175272     DOI: 10.1038/sj/dmfr/4600575

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  4 in total

1.  Comparison of digital systems and conventional dental film for the detection of approximal enamel caries.

Authors:  A A Pontual; D P de Melo; S M de Almeida; F N Bóscolo; F Haiter Neto
Journal:  Dentomaxillofac Radiol       Date:  2010-10       Impact factor: 2.419

2.  Compliance of Iranian dentists with safety standards of oral radiology.

Authors:  S Shahab; A Kavosi; H Nazarinia; S Mehralizadeh; M Mohammadpour; M Emami
Journal:  Dentomaxillofac Radiol       Date:  2012-02       Impact factor: 2.419

3.  Detection of artificial occlusal caries in a phosphor imaging plate system with two types of LCD monitors versus three different films.

Authors:  Mehmet Ilgüy; Semanur Dinçer; Dilhan Ilgüy; Gündüz Bayirli
Journal:  J Digit Imaging       Date:  2008-10-24       Impact factor: 4.056

4.  Effects of developer exhaustion on DFL Contrast FV-58 and Kodak Insight dental films.

Authors:  Fabiano Pachêco de Carvalho; M M F da Silveira; M A G Frazão; S T de Santana; M L dos Anjos Pontual
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.