Literature DB >> 25595866

Effect of display monitor devices on intra-oral radiographic caries diagnosis.

Kazuyuki Araki1, Mamiko Fujikura2, Tsukasa Sano2.   

Abstract

OBJECTIVES: Recent developments in digital computer technology have enabled radiological diagnosis to be performed using a monitor screen. In medical radiography, the importance of monitors has been shown in many diseases. Digital imaging and communication in medicine (DICOM)-compatible monitors are widely used. However, the effect of monitors on the diagnosis of oral disease has not yet been clarified and remains controversial. The aims of this study are to compare the caries diagnostic ability between DICOM monitors and other monitors and to examine if monitor capability affects the diagnosis.
MATERIALS AND METHODS: One hundred proximal surfaces of 50 extracted human upper premolar teeth were used as specimens. Intra-oral radiographs of all specimens were taken digitally. Three types of monitors were compared in terms of caries diagnostic ability: a DICOM standard-compatible monitor, a standardized personal computer (PC) monitor, and a tablet PC. Six oral radiologists diagnosed each radiograph independently. Areas under the receiver operating characteristic (ROC) curve were generated and compared.
RESULTS: Area under the ROC curve (AUC) of the DICOM monitor, PC monitor, and tablet PC was 0.68147, 0.67002, and 0.60189, respectively. There was no significant difference between the DICOM monitor and the PC monitor, but the tablet PC showed significantly lower accuracy. There were no significant differences among the monitors for dentin caries (p > 0.05).
CONCLUSIONS: DICOM-compatible monitors and PC monitors have similar capabilities, but tablet PCs showed lower diagnostic accuracy, especially for superficial caries. CLINICAL RELEVANCE: Appropriate monitors are needed for radiographic diagnosis on monitor screens.

Entities:  

Keywords:  Dental caries; Diagnostic accuracy; Digital radiography; Monitor; Receiver operating characteristic curve analysis

Mesh:

Year:  2015        PMID: 25595866     DOI: 10.1007/s00784-015-1401-z

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  15 in total

1.  Evaluation of interproximal caries using the IPad 2 and a liquid crystal display monitor.

Authors:  Werner H Shintaku; Mark Scarbecz; Jaqueline S Venturin
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2012-03-03

2.  Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report.

Authors:  Ehsan Samei; Aldo Badano; Dev Chakraborty; Ken Compton; Craig Cornelius; Kevin Corrigan; Michael J Flynn; Bradley Hemminger; Nick Hangiandreou; Jeffrey Johnson; Donna M Moxley-Stevens; William Pavlicek; Hans Roehrig; Lois Rutz; Jeffrey Shepard; Robert A Uzenoff; Jihong Wang; Charles E Willis
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

3.  ROC analysis for diagnostic accuracy of fracture by using different monitors.

Authors:  Zhigang Liang; Kuncheng Li; Xiaolin Yang; Xiangying Du; Jiabin Liu; Xin Zhao; Xiangdong Qi
Journal:  J Digit Imaging       Date:  2006-09       Impact factor: 4.056

4.  Recent developments in the Dorfman-Berbaum-Metz procedure for multireader ROC study analysis.

Authors:  Stephen L Hillis; Kevin S Berbaum; Charles E Metz
Journal:  Acad Radiol       Date:  2008-05       Impact factor: 3.173

Review 5.  Digital radiography and caries diagnosis.

Authors:  A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  1998-01       Impact factor: 2.419

6.  Effect of monitor display on detection of approximal caries lesions in digital radiographs.

Authors:  S Isidor; M Faaborg-Andersen; H Hintze; L-L Kirkevang; M Frydenberg; F Haiter-Neto; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2009-12       Impact factor: 2.419

7.  Diagnostic performance in differentiation of breast lesion on digital mammograms: comparison among hard-copy film, 3-megapixel LCD monitor, and 5-megapixel LCD monitor.

Authors:  Takeshi Kamitani; Hidetake Yabuuchi; Yoshio Matsuo; Taro Setoguchi; Shuji Sakai; Takashi Okafuji; Shunya Sunami; Masamitsu Hatakenaka; Nobuhide Ishii; Makoto Kubo; Eriko Tokunaga; Hidetaka Yamamoto; Hiroshi Honda
Journal:  Clin Imaging       Date:  2011 Sep-Oct       Impact factor: 1.605

8.  Effect of monitors on approximal caries detection in digital radiographs--standard versus precalibrated DICOM part 14 displays: an in vitro study.

Authors:  Kristina Hellén-Halme; Mats Nilsson; Arne Petersson
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-02-06

Review 9.  Caries detection and diagnosis: novel technologies.

Authors:  Iain A Pretty
Journal:  J Dent       Date:  2006-08-09       Impact factor: 4.379

10.  Digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis.

Authors:  Maryam Tofangchiha; Mamak Adel; Mahin Bakhshi; Mahsa Esfehani; Pantea Nazeman; Mojgan Ghorbani Elizeyi; Amir Javadi
Journal:  Iran Endod J       Date:  2013-01-20
View more
  5 in total

1.  Effect of display type, DICOM calibration and room illuminance in bitewing radiographs.

Authors:  Soili Kallio-Pulkkinen; Sisko Huumonen; Marianne Haapea; Esa Liukkonen; Annina Sipola; Osmo Tervonen; Miika T Nieminen
Journal:  Dentomaxillofac Radiol       Date:  2015-08-03       Impact factor: 2.419

2.  Impact of room lighting and image display device in the radiographic appearances of the endodontic treatments.

Authors:  Adriana D Cruz; Maria Cn Castro; Marcelo F Aguiar; Ludmilla S Guimarães; Cinthya C Gomes
Journal:  Dentomaxillofac Radiol       Date:  2018-03-12       Impact factor: 2.419

3.  Diagnostic Accuracy of Caries and Periapical Lesions on a Monitor with and without DICOM-GSDF Calibration Under Different Ambient Light Conditions.

Authors:  Rangel Teles Freire; Agnaldo Rocha Prata-Júnior; John Nadson Andrade Pinho; Wilton Mitsunari Takeshita
Journal:  J Digit Imaging       Date:  2022-02-15       Impact factor: 4.903

4.  Comparison of digital image displays performance in the detection of artificial internal root resorptions lesions.

Authors:  Matheus Nogueira da Hora; Lucas de Paula Lopes Rosado; Frederico Sampaio Neves; Ieda Crusoé-Rebello; Taruska Ventorini Vasconcelos
Journal:  Dentomaxillofac Radiol       Date:  2021-04-09       Impact factor: 3.525

5.  Impact of viewing conditions on the performance assessment of different computer monitors used for dental diagnostics.

Authors:  Thomas Hastie; Sascha Venske-Parker; Johan K M Aps
Journal:  Imaging Sci Dent       Date:  2021-02-09