Simultaneous misalignment correction for approximate circular cone-beam computed tomography.

Y Kyriakou1, R M Lapp, L Hillebrand, D Ertel, W A Kalender.   

Abstract

Currently, CT scanning is often performed using flat detectors which are mounted on C-arm units or dedicated gantries as in radiation therapy or micro CT. For perspective cone-beam backprojection of the Feldkamp type (FDK) the geometry of an approximately circular scan trajectory has to be available for reconstruction. If the system or the scan geometry is afflicted with geometrical instabilities, referred to as misalignment, a non-perfect approximate circular scan is the case. Reconstructing a misaligned scan without knowledge of the true trajectory results in severe artefacts in the CT images. Unlike current methods which use a pre-scan calibration of the geometry for defined scan protocols and calibration phantoms, we propose a real-time iterative restoration of reconstruction geometry by means of entropy minimization. Entropy minimization is performed combining a simplex algorithm for multi-parameter optimization and iterative graphics card (GPU)-based FDK-reconstructions. Images reconstructed with the misaligned geometry were used as an input for the entropy minimization algorithm. A simplex algorithm changes the geometrical parameters of the source and detector with respect to the reduction of entropy. In order to reduce the size of the high-dimensional space required for minimization, the trajectory was described by only eight fix points. A virtual trajectory is generated for each iteration using a least-mean-squares algorithm to calculate an approximately circular path including these points. Entropy was minimal for the ideal dataset, whereas strong misalignment resulted in a higher entropy value. For the datasets used in this study, the simplex algorithm required 64-200 iterations to achieve an entropy value equivalent to the ideal dataset, depending on the grade of misalignment using random initialization conditions. The use of the GPU reduced the time per iteration as compared to a quad core CPU-based backprojection by a factor of 10 resulting in a total of 15-20 ms per iteration, and thus providing an online geometry restoration after a total computation time of approximately 1-3 s, depending on the number of iterations. The proposed method provides accurate geometry restoration for approximately circular scans and eliminates the need for an elaborate off-line calibration for each scan. If a priori information about the trajectory is used to initialize the simplex algorithm, it is expected that the entropy minimization will converge significantly faster.

Mesh:

Year:  2008        PMID: 18936522     DOI: 10.1088/0031-9155/53/22/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

Review 1.  [Basic principles of flat detector computed tomography (FD-CT)].

Authors:  Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

2.  Metal artifact reduction for clipping and coiling in interventional C-arm CT.

Authors:  D Prell; Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

3.  Estimation of CT cone-beam geometry using a novel method insensitive to phantom fabrication inaccuracy: implications for isocenter localization accuracy.

Authors:  J Chetley Ford; Dandan Zheng; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

4.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment.

Authors:  Jang-Hwan Choi; Andreas Maier; Andreas Keil; Saikat Pal; Emily J McWalter; Gary S Beaupré; Garry E Gold; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

5.  Evaluation of motion artifact metrics for coronary CT angiography.

Authors:  Hongfeng Ma; Eric Gros; Aniko Szabo; Scott G Baginski; Zachary R Laste; Naveen M Kulkarni; Darin Okerlund; Taly G Schmidt
Journal:  Med Phys       Date:  2018-01-03       Impact factor: 4.071

6.  Self-calibration of cone-beam CT geometry using 3D-2D image registration.

Authors:  S Ouadah; J W Stayman; G J Gang; T Ehtiati; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-10       Impact factor: 3.609

7.  Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion.

Authors:  A Sisniega; J W Stayman; J Yorkston; J H Siewerdsen; W Zbijewski
Journal:  Phys Med Biol       Date:  2017-03-22       Impact factor: 3.609

8.  Maximum-Likelihood Calibration of an X-ray Computed Tomography System.

Authors:  Jared W Moore; Roel Van Holen; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010 Oct-Nov

9.  A line fiducial method for geometric calibration of cone-beam CT systems with diverse scan trajectories.

Authors:  M W Jacobson; M D Ketcha; S Capostagno; A Martin; A Uneri; J Goerres; T De Silva; S Reaungamornrat; R Han; A Manbachi; J W Stayman; S Vogt; G Kleinszig; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2018-01-16       Impact factor: 3.609

10.  Multimodality calibration for simultaneous fluoroscopic and nuclear imaging.

Authors:  Casper Beijst; Mattijs Elschot; Sandra van der Velden; Hugo W A M de Jong
Journal:  EJNMMI Phys       Date:  2016-08-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.