Literature DB >> 18818930

ACCURATUM: improved calcium volume scoring using a mesh-based algorithm--a phantom study.

Stefan C Saur1, Hatem Alkadhi, Lotus Desbiolles, Gábor Székely, Philippe C Cattin.   

Abstract

To overcome the limitations of the classical volume scoring method for quantifying coronary calcifications, including accuracy, variability between examinations, and dependency on plaque density and acquisition parameters, a mesh-based volume measurement method has been developed. It was evaluated and compared with the classical volume scoring method for accuracy, i.e., the normalized volume (measured volume/ground-truthed volume), and for variability between examinations (standard deviation of accuracy). A cardiac computed-tomography (CT) phantom containing various cylindrical calcifications was scanned using different tube voltages and reconstruction kernels, at various positions and orientations on the CT table and using different slice thicknesses. Mean accuracy for all plaques was significantly higher (p < 0.0001) for the proposed method (1.220 +/- 0.507) than for the classical volume score (1.896 +/- 1.095). In contrast to the classical volume score, plaque density (p = 0.84), reconstruction kernel (p = 0.19), and tube voltage (p = 0.27) had no impact on the accuracy of the developed method. In conclusion, the method presented herein is more accurate than classical calcium scoring and is less dependent on tube voltage, reconstruction kernel, and plaque density.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18818930     DOI: 10.1007/s00330-008-1181-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  Determination of the presampled MTF in computed tomography.

Authors:  J M Boone
Journal:  Med Phys       Date:  2001-03       Impact factor: 4.071

2.  Causes of interscan variability of coronary artery calcium measurements at electron-beam CT.

Authors:  Bin Lu; Matthew J Budoff; Nan Zhuang; Janis Child; Hamid Bakhsheshi; Sivi Carson; Song-Shou Mao
Journal:  Acad Radiol       Date:  2002-06       Impact factor: 3.173

3.  Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT.

Authors:  Andreas F Kopp; Bernd Ohnesorge; Christoph Becker; Stephen Schröder; Martin Heuschmid; Axel Küttner; Ronald Kuzo; Claus D Claussen
Journal:  Radiology       Date:  2002-10       Impact factor: 11.105

4.  Quantification of coronary artery calcium with multi-detector row CT: assessing interscan variability with different tube currents pilot study.

Authors:  Naoki Takahashi; Kyongtae T Bae
Journal:  Radiology       Date:  2003-07       Impact factor: 11.105

5.  Calcification of the coronary arteries.

Authors:  D H BLANKENHORN; D STERN
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1959-05

6.  Interscan variation in coronary artery calcium quantification in a large asymptomatic patient population.

Authors:  H C Yoon; J G Goldin; L E Greaser; J Sayre; G C Fonarow
Journal:  AJR Am J Roentgenol       Date:  2000-03       Impact factor: 3.959

7.  Volumetric quantification of atherosclerotic plaque in CT considering partial volume effect.

Authors:  Jamshid Dehmeshki; Xujiong Ye; Hamdan Amin; Maryam Abaei; Xinyu Lin; Salah D Qanadli
Journal:  IEEE Trans Med Imaging       Date:  2007-03       Impact factor: 10.048

8.  Dual-source computed tomography: advances of improved temporal resolution in coronary plaque imaging.

Authors:  Anja J Reimann; Daniel Rinck; Ayser Birinci-Aydogan; Michael Scheuering; Christof Burgstahler; Stephen Schroeder; Harald Brodoefel; Ilias Tsiflikas; Tina Herberts; Thomas Flohr; Claus D Claussen; Andreas F Kopp; Martin Heuschmid
Journal:  Invest Radiol       Date:  2007-03       Impact factor: 6.016

9.  Quantification of coronary artery calcium using ultrafast computed tomography.

Authors:  A S Agatston; W R Janowitz; F J Hildner; N R Zusmer; M Viamonte; R Detrano
Journal:  J Am Coll Cardiol       Date:  1990-03-15       Impact factor: 24.094

10.  Potential clinical impact of variability in the measurement of coronary artery calcification with sequential MDCT.

Authors:  Sandra S Halliburton; Arthur E Stillman; Michael Lieber; Jane M Kasper; Stacie A Kuzmiak; Richard D White
Journal:  AJR Am J Roentgenol       Date:  2005-02       Impact factor: 3.959

View more
  3 in total

1.  Generative models for reproducible coronary calcium scoring.

Authors:  Sanne G M van Velzen; Bob D de Vos; Julia M H Noothout; Helena M Verkooijen; Max A Viergever; Ivana Išgum
Journal:  J Med Imaging (Bellingham)       Date:  2022-05-31

2.  MRI and CT in the diagnosis of coronary artery disease: indications and applications.

Authors:  Konstantin Nikolaou; Hatem Alkadhi; Fabian Bamberg; Sebastian Leschka; Bernd J Wintersperger
Journal:  Insights Imaging       Date:  2010-11-23

3.  Coronary calcium scoring with partial volume correction in anthropomorphic thorax phantom and screening chest CT images.

Authors:  Jurica Šprem; Bob D de Vos; Nikolas Lessmann; Robbert W van Hamersvelt; Marcel J W Greuter; Pim A de Jong; Tim Leiner; Max A Viergever; Ivana Išgum
Journal:  PLoS One       Date:  2018-12-20       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.