Literature DB >> 17354634

Volumetric quantification of atherosclerotic plaque in CT considering partial volume effect.

Jamshid Dehmeshki1, Xujiong Ye, Hamdan Amin, Maryam Abaei, Xinyu Lin, Salah D Qanadli.   

Abstract

Coronary artery calcification (CAC) is quantified based on a computed tomography (CT) scan image. A calcified region is identified. Modified expectation maximization (MEM) of a statistical model for the calcified and background material is used to estimate the partial calcium content of the voxels. The algorithm limits the region over which MEM is performed. By using MEM, the statistical properties of the model are iteratively updated based on the calculated resultant calcium distribution from the previous iteration. The estimated statistical properties are used to generate a map of the partial calcium content in the calcified region. The volume of calcium in the calcified region is determined based on the map. The experimental results on a cardiac phantom, scanned 90 times using 15 different protocols, demonstrate that the proposed method is less sensitive to partial volume effect and noise, with average error of 9.5% (standard deviation (SD) of 5-7mm(3)) compared with 67% (SD of 3-20mm(3)) for conventional techniques. The high reproducibility of the proposed method for 35 patients, scanned twice using the same protocol at a minimum interval of 10 min, shows that the method provides 2-3 times lower interscan variation than conventional techniques.

Entities:  

Mesh:

Year:  2007        PMID: 17354634     DOI: 10.1109/TMI.2007.893344

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  ACCURATUM: improved calcium volume scoring using a mesh-based algorithm--a phantom study.

Authors:  Stefan C Saur; Hatem Alkadhi; Lotus Desbiolles; Gábor Székely; Philippe C Cattin
Journal:  Eur Radiol       Date:  2008-09-26       Impact factor: 5.315

2.  Generative models for reproducible coronary calcium scoring.

Authors:  Sanne G M van Velzen; Bob D de Vos; Julia M H Noothout; Helena M Verkooijen; Max A Viergever; Ivana Išgum
Journal:  J Med Imaging (Bellingham)       Date:  2022-05-31

3.  Improved coronary calcification quantification using photon-counting-detector CT: an ex vivo study in cadaveric specimens.

Authors:  Mårten Sandstedt; Jeffrey Marsh; Kishore Rajendran; Hao Gong; Shengzhen Tao; Anders Persson; Shuai Leng; Cynthia McCollough
Journal:  Eur Radiol       Date:  2021-03-13       Impact factor: 5.315

4.  Coronary calcium scoring with partial volume correction in anthropomorphic thorax phantom and screening chest CT images.

Authors:  Jurica Šprem; Bob D de Vos; Nikolas Lessmann; Robbert W van Hamersvelt; Marcel J W Greuter; Pim A de Jong; Tim Leiner; Max A Viergever; Ivana Išgum
Journal:  PLoS One       Date:  2018-12-20       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.