Literature DB >> 12832575

Quantification of coronary artery calcium with multi-detector row CT: assessing interscan variability with different tube currents pilot study.

Naoki Takahashi1, Kyongtae T Bae.   

Abstract

PURPOSE: To assess the interscan variability of coronary artery calcium as measured with different tube currents and quantification methods in prospective electrocardiography (ECG)-gated multi-detector row CT.
MATERIALS AND METHODS: Thirty-three subjects who were asymptomatic for coronary heart disease underwent prospective ECG-gated, subsecond multi-detector row CT of the heart. Each subject underwent two consecutive CT examinations, the first with a dose of either 40 mAs (n = 18) or 80 mAs (n = 15) and the second with a dose of 150 mAs. Calcium volume and calcium score were calculated. Pearson correlation coefficient was computed between the calcium scores of high- and low-dose examinations. Interscan variability in these measurements (ie, the absolute percentage difference) was compared between the examinations with 40-150 mAs and those with 80-150 mAs by using an independent sample t test. In addition, the interscan variabilities of calcium scores between vessels were evaluated with repeated measures of analysis of variance. The interscan variabilities between calcium score and volume measurement were also compared with paired t tests.
RESULTS: Twenty-seven of 33 subjects had coronary artery calcium deposits on both CT scans. Five subjects had no calcium deposit on either scan. One subject had calcium deposits on only one scan. The total calcium score between the high- and low-dose scans was highly correlated (r = 0.98) and was not significantly different (P =.58). The interscan variability of calcium score showed no significant difference with respect to subject (P =.25) or vessel (P =.84). The interscan variability of the calcium volume measurement was significantly lower than that of the calcium score with respect to both the subject (P <.01) and the vessel (P <.01).
CONCLUSION: A dose of 40 mAs appears adequate for quantifying coronary artery calcium at multi-detector row CT. Interscan variability of multi-detector row CT is substantially reduced by using the calcium volume method.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12832575     DOI: 10.1148/radiol.2281012035

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Fully automatic model-based calcium segmentation and scoring in coronary CT angiography.

Authors:  Dov Eilot; Roman Goldenberg
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-11-08       Impact factor: 2.924

2.  ACCURATUM: improved calcium volume scoring using a mesh-based algorithm--a phantom study.

Authors:  Stefan C Saur; Hatem Alkadhi; Lotus Desbiolles; Gábor Székely; Philippe C Cattin
Journal:  Eur Radiol       Date:  2008-09-26       Impact factor: 5.315

3.  Radiation dose threshold for coronary artery calcium score with MDCT: how low can you go?

Authors:  Tom D Newton; Hatem Mehrez; Kelly Wong; Ravi Menezes; Bernd J Wintersperger; Andrew Crean; Elsie Nguyen; Narinder Paul
Journal:  Eur Radiol       Date:  2011-06-03       Impact factor: 5.315

4.  Radiation dose reduction for coronary artery calcium scoring at 320-detector CT with adaptive iterative dose reduction 3D.

Authors:  Fuminari Tatsugami; Toru Higaki; Wataru Fukumoto; Yoko Kaichi; Chikako Fujioka; Masao Kiguchi; Hideya Yamamoto; Yasuki Kihara; Kazuo Awai
Journal:  Int J Cardiovasc Imaging       Date:  2015-03-10       Impact factor: 2.357

5.  Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study.

Authors:  Andreas H Mahnken; Georg Mühlenbruch; Ralf Koos; Marco Das; Saskia Pohl; Sven Stanzel; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2005-08-20       Impact factor: 5.315

6.  Feasibility of spectral shaping for detection and quantification of coronary calcifications in ultra-low dose CT.

Authors:  Marleen Vonder; Gert Jan Pelgrim; Sèvrin E M Huijsse; Mathias Meyer; Marcel J W Greuter; Thomas Henzler; Thomas G Flohr; Matthijs Oudkerk; Rozemarijn Vliegenthart
Journal:  Eur Radiol       Date:  2016-08-29       Impact factor: 5.315

  6 in total