Literature DB >> 18814010

Effect of laparoscopic grasper force transmission ratio on grasp control.

Eleonora P Westebring-van der Putten1, John J van den Dobbelsteen, Richard H M Goossens, Jack J Jakimowicz, Jenny Dankelman.   

Abstract

BACKGROUND: Surgeons may cause tissue damage by incorrect laparoscopic pinch force control. Unpredictable tissue and grasper properties may cause slips or ruptures. This study investigated how different forms of haptic feedback influence the surgeon's ability to generate a safe laparoscopic grasp while pulling tissues of variable stiffness using graspers with different force transmission ratios. The results will help define design requirements for training facilities and instruments.
METHODS: For this study, 10 participants lifted an object barehanded, with tweezers, or with one of two laparoscopic graspers until they where able to complete five consecutive safe lifts under different tissue stiffness conditions. The participants were presented with indirect visual feedback of pinch force, object location, and target location.
RESULTS: Lifting with instruments (tweezers or graspers) required 4.5 to 14.5 times as many practice trials as barehanded lifting, where no slips were recorded. Additionally, slips occurred more often with a decreasing force transmission ratio of the graspers and with increasing tissue stiffness. The maximal pinch force was higher in lifting with instruments than in barehanded lifting (26-60%) irrespective of the stiffness conditions. Using a grasper, the slip margin often was not high enough in the stiffest condition, resulting in slippage of up to 84%.
CONCLUSIONS: Without the direct tactile feedback that occurs with normal skin-tissue contact, subjects using graspers have trouble anticipating slippage when lifting tissue with variable stiffness. Performance drops with a decreased force transmission ratio of the instrument and increased tissue stiffness. Furthermore, the pinch forces are not adapted to the variable stiffness conditions. The same pinch force is applied irrespective of tissue stiffness. It takes participants longer to learn a safe laparoscopic grasp than to learn barehanded lifts. Additionally, to perform safe laparoscopic surgery, care should be taken when graspers with a low force transmission ratio are used.

Entities:  

Mesh:

Year:  2008        PMID: 18814010     DOI: 10.1007/s00464-008-0107-6

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  20 in total

1.  Grip force dynamics in the approach to a collision.

Authors:  Y N Turrell; F X Li; A M Wing
Journal:  Exp Brain Res       Date:  1999-09       Impact factor: 1.972

2.  Effectiveness of grasping and duration of clamping using laparoscopic graspers.

Authors:  E A M Heijnsdijk; J Dankelman; D J Gouma
Journal:  Surg Endosc       Date:  2002-05-07       Impact factor: 4.584

Review 3.  Internal models for bi-manual tasks.

Authors:  Alice G Witney
Journal:  Hum Mov Sci       Date:  2004-11       Impact factor: 2.161

4.  What can the operator actually feel when performing a laparoscopy?

Authors:  G Picod; A C Jambon; D Vinatier; P Dubois
Journal:  Surg Endosc       Date:  2004-10-26       Impact factor: 4.584

5.  The optimal mechanical efficiency of laparoscopic forceps.

Authors:  E A M Heijnsdijk; A Pasdeloup; J Dankelman; D J Gouma
Journal:  Surg Endosc       Date:  2004-10-13       Impact factor: 4.584

6.  Somatosensory control of precision grip during unpredictable pulling loads. I. Changes in load force amplitude.

Authors:  R S Johansson; R Riso; C Häger; L Bäckström
Journal:  Exp Brain Res       Date:  1992       Impact factor: 1.972

7.  Visual and somatosensory information about object shape control manipulative fingertip forces.

Authors:  P Jenmalm; R S Johansson
Journal:  J Neurosci       Date:  1997-06-01       Impact factor: 6.167

8.  Signals in tactile afferents from the fingers eliciting adaptive motor responses during precision grip.

Authors:  R S Johansson; G Westling
Journal:  Exp Brain Res       Date:  1987       Impact factor: 1.972

9.  Grip-load force coupling: a general control strategy for transporting objects.

Authors:  J R Flanagan; J R Tresilian
Journal:  J Exp Psychol Hum Percept Perform       Date:  1994-10       Impact factor: 3.332

10.  Inter- and intraindividual variabilities of perforation forces of human and pig bowel tissue.

Authors:  E A M Heijnsdijk; M van der Voort; H de Visser; J Dankelman; D J Gouma
Journal:  Surg Endosc       Date:  2003-10-23       Impact factor: 4.584

View more
  7 in total

1.  European Association of Endoscopic Surgeons (EAES) consensus statement on the use of robotics in general surgery.

Authors:  Amir Szold; Roberto Bergamaschi; Ivo Broeders; Jenny Dankelman; Antonello Forgione; Thomas Langø; Andreas Melzer; Yoav Mintz; Salvador Morales-Conde; Michael Rhodes; Richard Satava; Chung-Ngai Tang; Ramon Vilallonga
Journal:  Surg Endosc       Date:  2014-11-08       Impact factor: 4.584

2.  Perceiving haptic feedback in virtual reality simulators.

Authors:  Cecilie Våpenstad; Erlend Fagertun Hofstad; Thomas Langø; Ronald Mårvik; Magdalena Karolina Chmarra
Journal:  Surg Endosc       Date:  2013-01-26       Impact factor: 4.584

3.  Tying different knots: what forces do we use?

Authors:  S P Rodrigues; T Horeman; J Dankelman; J J van den Dobbelsteen; F W Jansen
Journal:  Surg Endosc       Date:  2014-10-11       Impact factor: 4.584

4.  Haptic simulators accelerate laparoscopic simulator training, but skills are not transferable to a non-haptic simulator: a randomized trial.

Authors:  Anishan Vamadevan; Lars Konge; Morten Stadeager; Flemming Bjerrum
Journal:  Surg Endosc       Date:  2022-08-02       Impact factor: 3.453

5.  Suturing intraabdominal organs: when do we cause tissue damage?

Authors:  Sharon P Rodrigues; Tim Horeman; Jenny Dankelman; John J van den Dobbelsteen; Frank-Willem Jansen
Journal:  Surg Endosc       Date:  2011-10-25       Impact factor: 4.584

6.  Robot-assisted subtotal pancreas-preserving duodenectomy.

Authors:  Mario Masrur; Federico Gheza; Paolo Raimondi; Stefano D'Ugo; David Calatayud; Pier C Giulianotti
Journal:  JSLS       Date:  2012 Oct-Dec       Impact factor: 2.172

7.  A Fully 3D-Printed Steerable Instrument for Minimally Invasive Surgery.

Authors:  Costanza Culmone; Kirsten Lussenburg; Joost Alkemade; Gerwin Smit; Aimée Sakes; Paul Breedveld
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.