PURPOSE: To describe a new method of alignment of toric intraocular lenses (IOLs) and evaluation of their rotation errors using anterior segment optical coherence tomography (AS-OCT).
METHODS: Twenty-nine eyes of 22 patients who had cataract extraction and implantation of an acrylic toric IOL were included. The new AS-OCT method was used for the alignment of toric IOLs and evaluation of their rotation errors. These rotation errors were evaluated and compared with those measured using the internal map of a wavefront aberrometer.
RESULTS: The mean rotation error ± standard deviation (SD) of the toric IOLs evaluated by AS-OCT was 3.2 ± 2.2° and 3.2 ± 2.4° at 1 week and 1 month after surgery, respectively. The mean difference in the reference axis between the visits was 1.8 ± 2.1°. The mean difference between the rotation errors of the alignment axes measured by AS-OCT and the internal map was 2.5 ± 1.9° (P = 0.037).
CONCLUSION: The current method is clinically useful not only for the accurate alignment of toric IOLs but also for evaluating their rotation errors.

Entities:  

Mesh:

Year:  2011        PMID: 22037797     DOI: 10.1007/s10384-011-0097-0

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  27 in total

1.  Limbal relaxing incision for the management of mixed astigmatism after photorefractive keratectomy and laser thermal keratoplasty.

Authors:  H Bayramlar; Y Totan; M C Daghoglu
Journal:  J Cataract Refract Surg       Date:  2000-09       Impact factor: 3.351

2.  Astigmatism correction with a foldable toric intraocular lens in cataract patients.

Authors:  I Ruhswurm; U Scholz; M Zehetmayer; G Hanselmayer; C Vass; C Skorpik
Journal:  J Cataract Refract Surg       Date:  2000-07       Impact factor: 3.351

3.  Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases.

Authors:  David F Chang
Journal:  J Cataract Refract Surg       Date:  2003-05       Impact factor: 3.351

4.  Long-term Staar toric intraocular lens rotational stability.

Authors:  Mario Jampaulo; Michael D Olson; Kevin M Miller
Journal:  Am J Ophthalmol       Date:  2008-07-26       Impact factor: 5.258

5.  Simplified system of marking the cornea for a toric intraocular lens.

Authors:  John M Graether
Journal:  J Cataract Refract Surg       Date:  2009-09       Impact factor: 3.351

6.  Toric intraocular lenses for correcting astigmatism in 130 eyes.

Authors:  X Y Sun; D Vicary; P Montgomery; M Griffiths
Journal:  Ophthalmology       Date:  2000-09       Impact factor: 12.079

Review 7.  Status of toric intraocular lenses.

Authors:  Jeffrey D Horn
Journal:  Curr Opin Ophthalmol       Date:  2007-02       Impact factor: 3.761

8.  Measurement of combined corneal, internal, and total ocular optical quality analysis in anterior segment pathology with the OPD-scan and OPD-station.

Authors:  Damien Gatinel; Thanh Hoang-Xuan
Journal:  J Refract Surg       Date:  2006-11       Impact factor: 3.573

9.  Limbal relaxing incisions to correct astigmatism in clear corneal cataract surgery.

Authors:  K Müller-Jensen; P Fischer; U Siepe
Journal:  J Refract Surg       Date:  1999 Sep-Oct       Impact factor: 3.573

10.  Changes in corneal astigmatism and high order aberrations after clear corneal tunnel phacoemulsification guided by corneal topography.

Authors:  Yongxiang Jiang; Qihua Le; Jin Yang; Yi Lu
Journal:  J Refract Surg       Date:  2006-11       Impact factor: 3.573

View more
  4 in total

1.  The effect of head tilt on keratometric measurement using the IOLMaster.

Authors:  C Y Park; J R Do; S H Kim; C-Y Lim; R S Chuck
Journal:  Eye (Lond)       Date:  2013-09-20       Impact factor: 3.775

2.  Comparison of clinical outcomes among 3 marking methods for toric intraocular lens implantation.

Authors:  Hideyuki Onishi; Hidemasa Torii; Kazuhiro Watanabe; Kazuo Tsubota; Kazuno Negishi
Journal:  Jpn J Ophthalmol       Date:  2016-03-09       Impact factor: 2.447

3.  Changes in corneal aberrations after cataract surgery.

Authors:  Yuki Hidaka; Takefumi Yamaguchi; Megumi Saiki; Murat Dogru; Kazuo Tsubota; Kazuno Negishi
Journal:  Jpn J Ophthalmol       Date:  2016-03-02       Impact factor: 2.447

4.  Comprehensive review of surgical microscopes: technology development and medical applications.

Authors:  Ling Ma; Baowei Fei
Journal:  J Biomed Opt       Date:  2021-01       Impact factor: 3.170

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.