Three-way comparison of methods for the measurement of the erythrocyte sedimentation rate.

Johnny Ndoni Mahlangu1, Melony Davids.   

Abstract

An erythrocyte sedimentation rate (ESR) is a nonspecific sickness index, which is not diagnostic of any particular disease, but which when elevated may indicate the presence of inflammation, infection, rheumatologic disease, or neoplasm. Technological advances continue to evolve to make this old test to conform to requirements of a modern analytical laboratory. In this evaluation, two new semi-automated ESR measuring systems, the HumaSed and ESR-Auto Plus (EAP), were compared with the Westergren method with regard to the accuracy and precision of ESR measurement, sample stability, and interference of various substances with the ESR assay. Samples from 125 patients were analyzed with the three methods and the results compared using linear regression and Bland-Altman plots. The mean ESR values of the HumaSed (32.10+/-4.86) and EAP (38.09+/-5.33) were comparable to that of the Westergren (31.54+/-4.94). The high correlation coefficients of 0.910-0.96 and the Bland-Altman scatter plots revealed good association and agreement between the three methods. Bias between the three methods was small and the imprecision was within acceptable limits. ESR analysis beyond 4 hr was found to be unacceptable owing to sample instability. There was bilirubin and lipid but not heparin interference in the two automated systems. Overall, two automated analyzers were found to be fast, reliable, standardized, simplified, and safe instruments with accuracy and precision for ESR measurement comparable to the Westergren. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18803269      PMCID: PMC6649097          DOI: 10.1002/jcla.20267

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  14 in total

1.  EDTA samples for the measurement of erythrocyte sedimentation rate using Sedimatic 100 analyser.

Authors:  J Horsti
Journal:  Clin Chem Lab Med       Date:  2001-10       Impact factor: 3.694

2.  Erythrocyte sedimentation rate: innovative techniques for an obsolete test?

Authors:  Mario Plebani
Journal:  Clin Chem Lab Med       Date:  2003-02       Impact factor: 3.694

3.  Validation of the Diesse Mini-Ves erythrocyte sedimentation rate (ESR) analyzer using the Westergren ESR method in patients with systemic inflammatory conditions.

Authors:  Marc R Happe; Daniel F Battafarano; David P Dooley; Thomas A Rennie; Frederick T Murphy; Thomas J Casey; John A Ward
Journal:  Am J Clin Pathol       Date:  2002-07       Impact factor: 2.493

4.  Determination of the length of sedimentation reaction (erythrocyte sedimentation rate) in non-anticoagulated blood with the Microtest 1.

Authors:  Elisa Piva; Paolo Fassina; Mario Plebani
Journal:  Clin Chem Lab Med       Date:  2002-07       Impact factor: 3.694

5.  On the temporal development of erythrocyte sedimentation rate using sealed vacuum tubes.

Authors:  A Kallner
Journal:  Am J Hematol       Date:  1991-07       Impact factor: 10.047

6.  [Evaluation of 3 automatic systems for measurement of the erythrocyte sedimentation rate].

Authors:  I Besson; M Kinder; J M Jou; J L Vives Corrons
Journal:  Sangre (Barc)       Date:  1995-04

Review 7.  The mystique of the erythrocyte sedimentation rate. A reappraisal of one of the oldest laboratory tests still in use.

Authors:  M Zlonis
Journal:  Clin Lab Med       Date:  1993-12       Impact factor: 1.935

8.  Validation of the Coulter LH 750 in a hospital reference laboratory.

Authors:  C Aulesa; I Pastor; D Naranjo; J Piqueras; R Galimany
Journal:  Lab Hematol       Date:  2003

9.  Inflammatory activity: capillary electrophoresis provides more information than erythrocyte sedimentation rate.

Authors:  Anders Larsson; Lars-Olof Hansson
Journal:  Ups J Med Sci       Date:  2005       Impact factor: 2.384

Review 10.  Giant-cell arteritis with normal erythrocyte sedimentation rate: case report and review of the literature.

Authors:  S Zweegman; B Makkink; C D Stehouwer
Journal:  Neth J Med       Date:  1993-04       Impact factor: 1.422

View more
  6 in total

1.  Evaluation of Ves-Matic Cube 200 for erythrocyte sedimentation rate determination.

Authors:  Sevilay Sezer; Fatma Meriç Yilmaz; Oğuzhan Kaya; Sema Uysal
Journal:  J Clin Lab Anal       Date:  2013-09       Impact factor: 2.352

2.  Microfluidic-based measurement of erythrocyte sedimentation rate for biophysical assessment of blood in an in vivo malaria-infected mouse.

Authors:  Yang Jun Kang; Young-Ran Ha; Sang-Joon Lee
Journal:  Biomicrofluidics       Date:  2014-08-05       Impact factor: 2.800

3.  Differences in erythrocyte sedimentation rates using a modified Westergren method and an alternate method.

Authors:  Elise Schapkaitz; Shilla RabuRabu; Marcel Engelbrecht
Journal:  J Clin Lab Anal       Date:  2018-08-26       Impact factor: 2.352

4.  Comparison of iSED and Ves-Matic Cube 200 Erythrocyte Sedimentation Rate Measurements With Westergren Method.

Authors:  Nihal Boğdaycioğlu; Fatma Meric Yilmaz; Sevilay Sezer; Esra Oğuz
Journal:  J Clin Lab Anal       Date:  2014-08-17       Impact factor: 2.352

5.  Test-1 analyzer and conventional Westergren method for erythrocyte sedimentation rate: A comparative study between two laboratories.

Authors:  Cigdem Sonmez; Ozlem Ceylan Dogan; Aysegul Ozturk Kaymak; Nedim Akkaya; Kadir Okhan Akin; Gulcan Guntas
Journal:  J Clin Lab Anal       Date:  2018-01-17       Impact factor: 2.352

6.  Erythrocyte sedimentation rate and hemoglobin-binding protein in free-living box turtles (Terrapene spp.).

Authors:  Laura Adamovicz; Sarah J Baker; Ethan Kessler; Marta Kelly; Samantha Johnson; John Winter; Christopher A Phillips; Matthew C Allender
Journal:  PLoS One       Date:  2020-06-17       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.