Literature DB >> 18802730

Sub-pixel localisation of passive micro-coil fiducial markers in interventional MRI.

Marc Rea1, Donald McRobbie, Haytham Elhawary, Zion T H Tse, Michael Lamperth, Ian Young.   

Abstract

OBJECTIVE: Electromechanical devices enable increased accuracy in surgical procedures, and the recent development of MRI-compatible mechatronics permits the use of MRI for real-time image guidance. Integrated imaging of resonant micro-coil fiducials provides an accurate method of tracking devices in a scanner with increased flexibility compared to gradient tracking. Here we report on the ability of ten different image-processing algorithms to track micro-coil fiducials with sub-pixel accuracy.
MATERIALS AND METHODS: Five algorithms: maximum pixel, barycentric weighting, linear interpolation, quadratic fitting and Gaussian fitting were applied both directly to the pixel intensity matrix and to the cross-correlation matrix obtained by 2D convolution with a reference image.
RESULTS: Using images of a 3 mm fiducial marker and a pixel size of 1.1 mm, intensity linear interpolation, which calculates the position of the fiducial centre by interpolating the pixel data to find the fiducial edges, was found to give the best performance for minimal computing power; a maximum error of 0.22 mm was observed in fiducial localisation for displacements up to 40 mm. The inherent standard deviation of fiducial localisation was 0.04 mm.
CONCLUSION: This work enables greater accuracy to be achieved in passive fiducial tracking.

Mesh:

Year:  2008        PMID: 18802730     DOI: 10.1007/s10334-008-0143-1

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  11 in total

1.  An optical system for wireless detuning of parallel resonant circuits.

Authors:  E Y Wong; Q Zhang; J L Duerk; J S Lewin; M Wendt
Journal:  J Magn Reson Imaging       Date:  2000-10       Impact factor: 4.813

2.  A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR-FISP) sequence.

Authors:  C Flask; D Elgort; E Wong; A Shankaranarayanan; J Lewin; M Wendt; J L Duerk
Journal:  J Magn Reson Imaging       Date:  2001-11       Impact factor: 4.813

3.  Renal embolization: feasibility of magnetic resonance-guidance using active catheter tracking and intraarterial magnetic resonance angiography.

Authors:  Christian Fink; Michael Bock; Reiner Umathum; Steffen Volz; Sven Zuehlsdorff; Rainer Grobholz; Hans-Ulrich Kauczor; Peter Hallscheidt
Journal:  Invest Radiol       Date:  2004-02       Impact factor: 6.016

4.  Design of a novel MRI compatible manipulator for image guided prostate interventions.

Authors:  Axel Krieger; Robert C Susil; Cynthia Ménard; Jonathan A Coleman; Gabor Fichtinger; Ergin Atalar; Louis L Whitcomb
Journal:  IEEE Trans Biomed Eng       Date:  2005-02       Impact factor: 4.538

5.  MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results.

Authors:  Dirk Beyersdorff; Axel Winkel; Bernd Hamm; Severin Lenk; Stefan A Loening; Matthias Taupitz
Journal:  Radiology       Date:  2004-12-22       Impact factor: 11.105

6.  Automatic passive tracking of an endorectal prostate biopsy device using phase-only cross-correlation.

Authors:  André de Oliveira; Jaane Rauschenberg; Dirk Beyersdorff; Wolfhard Semmler; Michael Bock
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

7.  Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters.

Authors:  R A Omary; O Unal; D S Koscielski; R Frayne; F R Korosec; C A Mistretta; C M Strother; T M Grist
Journal:  J Vasc Interv Radiol       Date:  2000-09       Impact factor: 3.464

8.  Integrated and interactive position tracking and imaging of interventional tools and internal devices using small fiducial receiver coils.

Authors:  G A Coutts; D J Gilderdale; M Chui; L Kasuboski; N M DeSouza
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

9.  Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization.

Authors:  M Burl; G A Coutts; I R Young
Journal:  Magn Reson Med       Date:  1996-09       Impact factor: 4.668

10.  Real-time position monitoring of invasive devices using magnetic resonance.

Authors:  C L Dumoulin; S P Souza; R D Darrow
Journal:  Magn Reson Med       Date:  1993-03       Impact factor: 4.668

View more
  3 in total

1.  On precise localization of boundaries between extended uniform objects in MRI: tooth imaging as an example.

Authors:  Olga Tymofiyeva; Florian Schmid; Markus von Kienlin; Felix A Breuer; Kurt Rottner; Julian Boldt; Ernst-Juergen Richter; Peter M Jakob
Journal:  MAGMA       Date:  2010-09-29       Impact factor: 2.310

2.  Catheter tip tracking for MR-guided interventions using discrete Kalman filter and mean shift localization.

Authors:  Abubakr Eldirdiri; Frédéric Courivaud; Rafael Palomar; Per Kristian Hol; Ole Jakob Elle
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-08-23       Impact factor: 2.924

3.  Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions.

Authors:  Francesca Galassi; Djordje Brujic; Marc Rea; Nicholas Lambert; Nandita Desouza; Mihailo Ristic
Journal:  MAGMA       Date:  2014-05-07       Impact factor: 2.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.