Literature DB >> 10997475

Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters.

R A Omary1, O Unal, D S Koscielski, R Frayne, F R Korosec, C A Mistretta, C M Strother, T M Grist.   

Abstract

PURPOSE: To test the hypothesis that real-time magnetic resonance (MR) imaging-guided passive catheter tracking is feasible with use of dilute gadolinium (Gd)-filled catheters, to determine the optimal Gd concentration required for tracking, and to measure catheter tip tracking accuracy.
MATERIALS AND METHODS: The authors tested a real-time, T1-weighted, two-dimensional, spoiled gradient-recalled echo MR imaging sequence suitable for tracking catheters. In a yogurt phantom, the authors placed 5-F catheters filled with 2%-12% Gd solutions. MR imaging was performed with and without use of a projection dephaser that suppressed background signal. The authors measured signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and enhancement ratio to determine the optimal Gd concentration for catheter depiction. Catheter tip tracking accuracy was measured in an acrylic phantom with use of linear regression analysis, with goodness of fit assessed statistically with the F test.
RESULTS: Peak catheter SNR, CNR, and enhancement ratios were obtained with 4%-6% Gd concentrations. Tip tracking accuracy was determined to be +/- 0.41 mm (R2 = 0.99; P < .0001). MR imaging reconstructions were displayed up to 3.1 frames/sec.
CONCLUSIONS: Accurate MR imaging-guided passive catheter tracking was feasible in real-time with use of dilute Gd-filled catheters. This technique may have application in MR imaging-guided endovascular procedures.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10997475     DOI: 10.1016/s1051-0443(07)61343-8

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  24 in total

1.  A brief review of hardware for catheter tracking in magnetic resonance imaging.

Authors:  Jeffrey L Duerk; Eddy Y Wong; Jonathan S Lewin
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

2.  Catheter-based endomyocardial injection with real-time magnetic resonance imaging.

Authors:  Robert J Lederman; Michael A Guttman; Dana C Peters; Richard B Thompson; Jonathan M Sorger; Alexander J Dick; Venkatesh K Raman; Elliot R McVeigh
Journal:  Circulation       Date:  2002-03-19       Impact factor: 29.690

3.  Real-time volume rendered MRI for interventional guidance.

Authors:  Michael A Guttman; Robert J Lederman; Jonathan M Sorger; Elliot R McVeigh
Journal:  J Cardiovasc Magn Reson       Date:  2002       Impact factor: 5.364

Review 4.  The future of real-time cardiac magnetic resonance imaging.

Authors:  Krishna S Nayak; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

Review 5.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

6.  Low-dose intra-arterial contrast-enhanced MR aortography in patients based on a theoretically derived injection protocol.

Authors:  S Potthast; A-C Schulte; G M Bongartz; R Hügli; M Aschwanden; D Bilecen
Journal:  Eur Radiol       Date:  2005-06-21       Impact factor: 5.315

Review 7.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

8.  B1 field-insensitive transformers for RF-safe transmission lines.

Authors:  Axel Krafft; Sven Müller; Reiner Umathum; Wolfhard Semmler; Michael Bock
Journal:  MAGMA       Date:  2006-11-18       Impact factor: 2.310

Review 9.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11

Review 10.  Magnetic Resonance Sequences and Rapid Acquisition for MR-Guided Interventions.

Authors:  Adrienne E Campbell-Washburn; Anthony Z Faranesh; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.