Literature DB >> 18429016

Automatic passive tracking of an endorectal prostate biopsy device using phase-only cross-correlation.

André de Oliveira1, Jaane Rauschenberg, Dirk Beyersdorff, Wolfhard Semmler, Michael Bock.   

Abstract

MR-guided transrectal prostate biopsy is currently a time-consuming procedure because the imaging slice is often manually realigned with the biopsy needle during lesion targeting. In this work a pulse sequence is presented that automatically follows a passive marker attached to a dedicated MR biopsy device holder, thus providing an alternative to existing active tracking methods. In two orthogonal tracking FLASH images of the marker the position of the needle axis is automatically identified using a phase-only cross-correlation (POCC) algorithm. The position information is then used to realign a trueFISP imaging slice in real time. In phantom experiments the sensitivity of this technique to initial misalignments of the marker and to the signal-to-noise ratio was evaluated. In several puncture experiments the precision of the needle placement was analyzed. The POCC algorithm allowed for a precise identification of the marker in the images even under severe initial misalignments of up to 45 degrees. At a frame rate 1 image/s a precision of the needle placement of 1.5 +/- 1.1 mm could be achieved. (c) 2008 Wiley-Liss, Inc.

Mesh:

Year:  2008        PMID: 18429016     DOI: 10.1002/mrm.21430

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  Sub-pixel localisation of passive micro-coil fiducial markers in interventional MRI.

Authors:  Marc Rea; Donald McRobbie; Haytham Elhawary; Zion T H Tse; Michael Lamperth; Ian Young
Journal:  MAGMA       Date:  2008-09-19       Impact factor: 2.310

2.  Simultaneous slice excitation for accelerated passive marker tracking via phase-only cross correlation (POCC) in MR-guided needle interventions.

Authors:  Andreas Reichert; Michael Bock; Simon Reiss; Christiaan G Overduin; Jurgen J Fütterer; Axel Joachim Krafft
Journal:  MAGMA       Date:  2018-09-06       Impact factor: 2.310

3.  Configurable automatic detection and registration of fiducial frames for device-to-image registration in MRI-guided prostate interventions.

Authors:  Junichi Tokuda; Sang-Eun Song; Kemal Tuncali; Clare Tempany; Nobuhiko Hata
Journal:  Med Image Comput Comput Assist Interv       Date:  2013

4.  Motion compensation for MRI-compatible patient-mounted needle guide device: estimation of targeting accuracy in MRI-guided kidney cryoablations.

Authors:  Junichi Tokuda; Laurent Chauvin; Brian Ninni; Takahisa Kato; Franklin King; Kemal Tuncali; Nobuhiko Hata
Journal:  Phys Med Biol       Date:  2018-04-13       Impact factor: 3.609

5.  Autonomous real-time interventional scan plane control with a 3-D shape-sensing needle.

Authors:  Santhi Elayaperumal; Juan Camilo Plata; Andrew B Holbrook; Yong-Lae Park; Kim Butts Pauly; Bruce L Daniel; Mark R Cutkosky
Journal:  IEEE Trans Med Imaging       Date:  2014-06-23       Impact factor: 10.048

6.  In-bore setup and software for 3T MRI-guided transperineal prostate biopsy.

Authors:  Junichi Tokuda; Kemal Tuncali; Iulian Iordachita; Sang-Eun Song; Andriy Fedorov; Sota Oguro; Andras Lasso; Fiona M Fennessy; Clare M Tempany; Nobuhiko Hata
Journal:  Phys Med Biol       Date:  2012-09-05       Impact factor: 3.609

7.  Development of a robust MRI fiducial system for automated fusion of MR-US abdominal images.

Authors:  Christopher P Favazza; Krzysztof R Gorny; Matthew R Callstrom; Anil N Kurup; Michael Washburn; Pamela S Trester; Charles L Fowler; Nicholas J Hangiandreou
Journal:  J Appl Clin Med Phys       Date:  2018-05-21       Impact factor: 2.102

8.  Percutaneous MR-guided interventions using an optical Moiré Phase tracking system: Initial results.

Authors:  Urte Kägebein; Frank Godenschweger; Brian S R Armstrong; Georg Rose; Frank K Wacker; Oliver Speck; Bennet Hensen
Journal:  PLoS One       Date:  2018-10-16       Impact factor: 3.240

9.  GantryMate: A Modular MR-Compatible Assistance System for MR-Guided Needle Interventions.

Authors:  Andreas Reichert; Michael Bock; Michael Vogele; Axel Joachim Krafft
Journal:  Tomography       Date:  2019-06

10.  Fast and accurate localization of multiple RF markers for tracking in MRI-guided interventions.

Authors:  Francesca Galassi; Djordje Brujic; Marc Rea; Nicholas Lambert; Nandita Desouza; Mihailo Ristic
Journal:  MAGMA       Date:  2014-05-07       Impact factor: 2.310

View more