Literature DB >> 18799833

Optically stimulated luminescence (OSL) dosimetry in medicine.

E G Yukihara1, S W S McKeever.   

Abstract

This paper reviews fundamental and practical aspects of optically stimulated luminescence (OSL) dosimetry pertaining to applications in medicine, having particularly in mind new researchers and medical physicists interested in gaining familiarity with the field. A basic phenomenological model for OSL is presented and the key processes affecting the outcome of an OSL measurement are discussed. Practical aspects discussed include stimulation modalities (continuous-wave OSL, pulsed OSL and linear modulation OSL), basic experimental setup, available OSL readers, optical fiber systems and basic properties of available OSL dosimeters. Finally, results from the recent literature on applications of OSL in radiotherapy, radiodiagnostics and heavy charged particle dosimetry are discussed in light of the theoretical and practical framework presented in this review. Open questions and future challenges in OSL dosimetry are highlighted as a guide to the research needed to further advance the field.

Entities:  

Mesh:

Year:  2008        PMID: 18799833     DOI: 10.1088/0031-9155/53/20/R01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology.

Authors:  A Endo; T Katoh; I Kobayashi; R Joshi; J Sur; T Okano
Journal:  Dentomaxillofac Radiol       Date:  2011-11-24       Impact factor: 2.419

2.  Angular dependence of the nanoDot OSL dosimeter.

Authors:  James R Kerns; Stephen F Kry; Narayan Sahoo; David S Followill; Geoffrey S Ibbott
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

Review 3.  A review of recent advances in optical fibre sensors for in vivo dosimetry during radiotherapy.

Authors:  S O'Keeffe; D McCarthy; P Woulfe; M W D Grattan; A R Hounsell; D Sporea; L Mihai; I Vata; G Leen; E Lewis
Journal:  Br J Radiol       Date:  2015-03-11       Impact factor: 3.039

4.  Characterization of the nanoDot OSLD dosimeter in CT.

Authors:  Sarah B Scarboro; Dianna Cody; Paola Alvarez; David Followill; Laurence Court; Francesco C Stingo; Di Zhang; Michael McNitt-Gray; Stephen F Kry
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

5.  Measuring the radiation exposed with optically stimulated luminescent dosimeters and evaluation of the total time and dose of fluoroscopy.

Authors:  Sever Çaglar; Yaşar Mahsut Dinçel; Yavuz Arıkan; Osman Nuri Özyalvaç; Barış Özkul; Ali Öner
Journal:  J Clin Orthop Trauma       Date:  2018-07-21

Review 6.  Optical and x-ray technology synergies enabling diagnostic and therapeutic applications in medicine.

Authors:  Brian W Pogue; Brian C Wilson
Journal:  J Biomed Opt       Date:  2018-10       Impact factor: 3.170

7.  Potential of dosage reduction in cone-beam-computed tomography (CBCT) for radiological diagnostics of the paranasal sinuses.

Authors:  C Güldner; A Ningo; J Voigt; I Diogo; J Heinrichs; R Weber; T Wilhelm; M Fiebich
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-09-18       Impact factor: 2.503

8.  An interlaboratory comparison of dosimetry for a multi-institutional radiobiological research project: Observations, problems, solutions and lessons learned.

Authors:  Thomas M Seed; Shiyun Xiao; Nancy Manley; Janko Nikolich-Zugich; Jason Pugh; Marcel Van den Brink; Yoko Hirabayashi; Koji Yasutomo; Atsushi Iwama; Shigeo Koyasu; Ivo Shterev; Gregory Sempowski; Francesca Macchiarini; Kei Nakachi; Keith C Kunugi; Clifford G Hammer; Lawrence A Dewerd
Journal:  Int J Radiat Biol       Date:  2015-11-17       Impact factor: 2.694

9.  Dosimetric verification of lung cancer treatment using the CBCTs estimated from limited-angle on-board projections.

Authors:  You Zhang; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

10.  Radiation Doses in Patient Eye Lenses during Interventional Neuroradiology Procedures.

Authors:  R M Sánchez; E Vañó; J M Fernández; S Rosati; L López-Ibor
Journal:  AJNR Am J Neuroradiol       Date:  2015-11-05       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.