Radiation Doses in Patient Eye Lenses during Interventional Neuroradiology Procedures.

R M Sánchez1, E Vañó2, J M Fernández2, S Rosati3, L López-Ibor3.   

Abstract

BACKGROUND AND
PURPOSE: Eye lenses are among the most sensitive organs to x-ray radiation and may be considered at risk during neurointerventional radiology procedures. The threshold dose to produce eye lens opacities has been recently reduced to 500 mGy by the International Commission on Radiologic Protection. In this article, the authors investigated the radiation doses delivered to patients' eyes during interventional neuroradiology procedures at a university hospital.
MATERIALS AND METHODS: Small optically stimulated luminescence dosimeters were located over patients' eyes during 5 diagnostic and 31 therapeutic procedures performed in a biplane x-ray system. Phantom measurements were also made to determine the level of radiation to the eye during imaging runs with conebeam CT.
RESULTS: The left eye (located toward the lateral C-arm x-ray source) received a 4.5 times greater dose than the right one. The average dose during embolization in the left eye was 300 mGy, with a maximum of 2000 mGy in a single procedure. The patient who received this maximum eye dose needed 6 embolization procedures to treat his high-volume AVM. If one took into account those 6 embolizations, the eye dose could be 2-fold. Sixteen percent of the embolizations resulted in eye doses of >500 mGy.
CONCLUSIONS: A relevant fraction of patients received eye doses exceeding the threshold of 500 mGy. A careful optimization of the procedures and follow-up of these patients to evaluate potential lens opacities should be considered.
© 2016 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2015        PMID: 26542238      PMCID: PMC7960141          DOI: 10.3174/ajnr.A4549

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  15 in total

1.  Proposed local diagnostic reference levels in angiography and interventional neuroradiology and a preliminary analysis according to the complexity of the procedures.

Authors:  Loredana D'Ercole; Federico Zappoli Thyrion; Milena Bocchiola; Laura Mantovani; Catherine Klersy
Journal:  Phys Med       Date:  2010-11-11       Impact factor: 2.685

2.  Radiation dose evaluation in tomosynthesis and C-arm cone-beam CT examinations with an anthropomorphic phantom.

Authors:  Shuji Koyama; Takahiko Aoyama; Nobuhiro Oda; Chiyo Yamauchi-Kawaura
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  Patient dosimetry for x rays used in medical imaging.

Authors: 
Journal:  J ICRU       Date:  2005-12

5.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

Review 6.  ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context.

Authors:  F A Stewart; A V Akleyev; M Hauer-Jensen; J H Hendry; N J Kleiman; T J Macvittie; B M Aleman; A B Edgar; K Mabuchi; C R Muirhead; R E Shore; W H Wallace
Journal:  Ann ICRP       Date:  2012-02

7.  A proposed grading system for arteriovenous malformations. 1986.

Authors:  Robert F Spetzler; Neil A Martin
Journal:  J Neurosurg       Date:  2008-01       Impact factor: 5.115

8.  Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements.

Authors:  Paul A Jursinic
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

9.  Postoperative cataract cases among atomic bomb survivors: radiation dose response and threshold.

Authors:  Kazuo Neriishi; Eiji Nakashima; Atsushi Minamoto; Saeko Fujiwara; Masazumi Akahoshi; Hiromu K Mishima; Takashi Kitaoka; Roy E Shore
Journal:  Radiat Res       Date:  2007-10       Impact factor: 2.841

10.  Local skin and eye lens equivalent doses in interventional neuroradiology.

Authors:  Michael Sandborg; Sandro Rossitti; Håkan Pettersson
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

View more
  7 in total

1.  Lens dose reduction with a bismuth shield in neuro cone-beam computed tomography: an investigation on optimum shield device placement conditions.

Authors:  Satoru Kawauchi; Koichi Chida; Yusuke Hamada; Wataro Tsuruta
Journal:  Radiol Phys Technol       Date:  2021-11-18

2.  Real-time Detection of Patient Head Position and Cephalometric Landmarks from Neuro-Interventional Procedure Images Using Machine Learning for Patient Eye-Lens Dose Prediction.

Authors:  J Collins; J Troville; K Williams; S Rudin; D R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

3.  Estimation of Patient Eye-Lens Dose During Neuro-Interventional Procedures using a Dense Neural Network (DNN).

Authors:  J Collins; S Sun; C Guo; A Podgorsak; S Rudin; D R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

4.  Investigating the parameters that affect the radiation exposure and establishing typical values based on procedure complexity for cerebral angiography and brain aneurysm embolization.

Authors:  Chadia Rizk; Ghassan Abi Chedid; Christine Salem; Jad Farah
Journal:  Neuroradiology       Date:  2020-10-14       Impact factor: 2.804

Review 5.  Unintended and Accidental Exposures, Significant Dose Events and Trigger Levels in Interventional Radiology.

Authors:  Werner Jaschke; Gabriel Bartal; Colin J Martin; Eliseo Vano
Journal:  Cardiovasc Intervent Radiol       Date:  2020-05-20       Impact factor: 2.740

6.  European consensus on patient contact shielding.

Authors:  Peter Hiles; Patrick Gilligan; John Damilakis; Eric Briers; Cristian Candela-Juan; Dario Faj; Shane Foley; Guy Frija; Claudio Granata; Hugo de Las Heras Gala; Ruben Pauwels; Marta Sans Merce; Georgios Simantirakis; Eliseo Vano
Journal:  Insights Imaging       Date:  2021-12-23

Review 7.  Notifications and alerts in patient dose values for computed tomography and fluoroscopy-guided interventional procedures.

Authors:  Eliseo Vano; Reinhard Loose; Guy Frija; Graciano Paulo; Efstathios Efstathopoulos; Claudio Granata; Riccardo Corridori; Alberto Torresin; Jonas S Andersson; Virginia Tsapaki; Josefin Ammon; Christoph Hoeschen
Journal:  Eur Radiol       Date:  2022-03-16       Impact factor: 7.034

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.