Literature DB >> 18781349

Can we do without mydriasis in multifocal ERG recordings?

Charlotte M Poloschek1, Michael Bach.   

Abstract

The purpose of this study is to determine whether mfERG recordings with natural pupils approximate recordings obtained in mydriasis if the stimulus luminance is adjusted. If so, a bright monitor could obviate pupil dilation, rendering clinical management considerably easier. In 11 eyes of six subjects, we took four mfERG recordings with a resolution of 61 scaled hexagons per eye, two with natural pupils and two in mydriasis with a luminance of 150 cd/m(2) and 500 cd/m(2), respectively. Conditions will be abbreviated as "LoNat, HiNat, LoDil, and HiDil," where Lo/Hi stands for low vs. high luminance and Nat/Dil stands for natural vs. dilated pupils. Response densities and peak times were averaged for the central seven and the remaining 54 hexagons. An ANOVA found highly significant effects for both amplitude and peak time between the four recording conditions (P always <0.001). However, for the two "middle" conditions, HiNat and LoDil, amplitudes and peak times did not differ markedly. Retinal illuminances of the conditions LoNat and HiNat each differed from the conditions LoDil and HiDil, respectively, by a factor of 5.4. Amplitudes increased and peak times decreased in the order of conditions LoNat, HiNat, LoDil, HiDil. When data were corrected for the Stiles-Crawford effect, there was an inversion of effective retinal illuminances of the recordings HiNat and LoDil. The mfERG guidelines correspond to the condition LoDil; for all practical purposes, the amplitudes and peak times are the same when the HiNat condition is used. Thus, when clinical constraints render pupil dilation undesirable, the mfERG can be recorded with natural pupils when monitor luminance is increased by five times (if available).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18781349     DOI: 10.1007/s10633-008-9146-5

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  12 in total

1.  Effects of refractive blur on the multifocal electroretinogram.

Authors:  A M Palmowski; T Berninger; R Allgayer; H Andrielis; B Heinemann-Vernaleken; G Rudolph
Journal:  Doc Ophthalmol       Date:  1999       Impact factor: 2.379

2.  Pupillary responses to stimulus structure, colour and movement.

Authors:  J L Barbur; A J Harlow; A Sahraie
Journal:  Ophthalmic Physiol Opt       Date:  1992-04       Impact factor: 3.117

3.  Relation between directional sensitivity and spectral response curves in human cone vision.

Authors:  P L WALRAVEN; M A BOUMAN
Journal:  J Opt Soc Am       Date:  1960-08

4.  The field topography of ERG components in man--I. The photopic luminance response.

Authors:  E E Sutter; D Tran
Journal:  Vision Res       Date:  1992-03       Impact factor: 1.886

5.  The influence of luminance on the multifocal ERG.

Authors:  Thilo Schimitzek; Michael Bach
Journal:  Doc Ophthalmol       Date:  2006-11-16       Impact factor: 2.379

Review 6.  People and eyes: statistical approaches in ophthalmology.

Authors:  I E Murdoch; S S Morris; S N Cousens
Journal:  Br J Ophthalmol       Date:  1998-08       Impact factor: 4.638

7.  [The effect of the pupil as aperture and field stop on the various components of the human electroretinogram (author's transl)].

Authors:  M L Hoffmann; E Zrenner; H J Langhof
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1978-06-19

8.  Parametric representation of Stiles-Crawford functions: normal variation of peak location and directionality.

Authors:  R A Applegate; V Lakshminarayanan
Journal:  J Opt Soc Am A       Date:  1993-07       Impact factor: 2.129

9.  A basic investigation of multifocal electroretinogram: reproducibility and effect of luminance.

Authors:  M Yoshii; K Yanashima; T Wakaguri; F Sakemi; Y Kikuchi; S Suzuki; S Okisaka
Journal:  Jpn J Ophthalmol       Date:  2000 Mar-Apr       Impact factor: 2.447

10.  ISCEV guidelines for clinical multifocal electroretinography (2007 edition).

Authors:  Donald C Hood; Michael Bach; Mitchell Brigell; David Keating; Mineo Kondo; Jonathan S Lyons; Anja M Palmowski-Wolfe
Journal:  Doc Ophthalmol       Date:  2007-10-31       Impact factor: 2.379

View more
  4 in total

Review 1.  Essentials of photometry for clinical electrophysiology of vision.

Authors:  Daphne L McCulloch; Ruth Hamilton
Journal:  Doc Ophthalmol       Date:  2010-05-26       Impact factor: 2.379

2.  Influence of N(2)O(4) on multifocal electroretinogram in winstar mice.

Authors:  Lian-Na Hu; Chang-Yu Qiu; Hong-Xin Yan; Ling Luo; Jun Zhao; Hui-Ling Guo; Fu-Lin Gao; Zhi-Sheng Li; Nan Ma
Journal:  Int J Ophthalmol       Date:  2010-09-18       Impact factor: 1.779

3.  Correlation between multifocal pattern electroretinography and Fourier-domain OCT in eyes with temporal hemianopia from chiasmal compression.

Authors:  Mário L R Monteiro; Kenzo Hokazono; Leonardo P Cunha; Maria K Oyamada
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-29       Impact factor: 3.117

4.  Multifocal Electroretinography in the Presence of Temporal and Spatial Correlations and Eye Movements.

Authors:  Alan B Saul; Amber E Still
Journal:  Vision (Basel)       Date:  2016-05-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.