Literature DB >> 18777918

On-board four-dimensional digital tomosynthesis: first experimental results.

Jacqueline Maurer1, Devon Godfrey, Zhiheng Wang, Fang-Fang Yin.   

Abstract

The purpose of this study is to propose four-dimensional digital tomosynthesis (4D-DTS) for on-board analysis of motion information in three dimensions. Images of a dynamic motion phantom were reconstructed using acquisition scan angles ranging from 20 degrees (DTS) to full 360 degrees cone-beam computed tomography (CBCT). Projection images were acquired using an on-board imager mounted on a clinical linear accelerator. Three-dimensional (3D) images of the moving target were reconstructed for various scan angles. 3D respiratory correlated phase images were also reconstructed. For phase-based image reconstructions, the trajectory of a radiopaque marker was tracked in projection space and used to retrospectively assign respiratory phases to projections. The projections were then sorted according phase and used to reconstruct motion correlated images. By using two sets of projections centered about anterior-posterior and lateral axes, this study demonstrates how phase resolved coronal and sagittal DTS images can be used to obtain 3D motion information. Motion artifacts in 4D-DTS phase images are compared with those present in four-dimensional CT (4DCT) images. Due to the nature of data acquisition for the two modalities, superior-inferior motion artifacts are suppressed to a greater extent in 4D-DTS images compared with 4DCT. Theoretical derivations and experimental results are presented to demonstrate how optimal selection of image acquisition parameters including the frequency of projection acquisition and the phase window depend on the respiratory period. Two methods for acquiring projections are discussed. Preliminary results indicate that 4D-DTS can be used to acquire valuable kinetic information of internal anatomy just prior to radiation treatment.

Entities:  

Mesh:

Year:  2008        PMID: 18777918     DOI: 10.1118/1.2953561

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  In-treatment 4D cone-beam CT with image-based respiratory phase recognition.

Authors:  Satoshi Kida; Yoshitaka Masutani; Hideomi Yamashita; Toshikazu Imae; Taeko Matsuura; Naoya Saotome; Kuni Ohtomo; Keiichi Nakagawa; Akihiro Haga
Journal:  Radiol Phys Technol       Date:  2012-02-25

2.  Accuracy estimation for projection-to-volume targeting during rotational therapy: a feasibility study.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

3.  Technical Note: Imaging dose resulting from optimized procedures with limited-angle intrafractional verification system during stereotactic body radiation therapy lung treatment.

Authors:  George X Ding; Yawei Zhang; Lei Ren
Journal:  Med Phys       Date:  2019-04-29       Impact factor: 4.071

4.  Preliminary clinical evaluation of a 4D-CBCT estimation technique using prior information and limited-angle projections.

Authors:  You Zhang; Fang-Fang Yin; Tinsu Pan; Irina Vergalasova; Lei Ren
Journal:  Radiother Oncol       Date:  2015-03-26       Impact factor: 6.280

5.  Estimating 4D-CBCT from prior information and extremely limited angle projections using structural PCA and weighted free-form deformation for lung radiotherapy.

Authors:  Wendy Harris; You Zhang; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.071

6.  Evaluation of respiration-correlated digital tomosynthesis in lung.

Authors:  Joseph Santoro; Sergey Kriminski; D Michael Lovelock; Kenneth Rosenzweig; Hassan Mostafavi; Howard I Amols; Gig S Mageras
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

7.  Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy.

Authors:  Yawei Zhang; Fang-Fang Yin; You Zhang; Lei Ren
Journal:  Phys Med Biol       Date:  2017-03-24       Impact factor: 3.609

8.  Image acquisition optimization of a limited-angle intrafraction verification (LIVE) system for lung radiotherapy.

Authors:  Yawei Zhang; Xinchen Deng; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2017-11-30       Impact factor: 4.071

9.  Markerless tumor tracking using short kilovoltage imaging arcs for lung image-guided radiotherapy.

Authors:  Chun-Chien Shieh; Paul J Keall; Zdenka Kuncic; Chen-Yu Huang; Ilana Feain
Journal:  Phys Med Biol       Date:  2015-11-19       Impact factor: 3.609

10.  Experimental and numerical studies on kV scattered x-ray imaging for real-time image guidance in radiation therapy.

Authors:  Yanqi Huang; Kai Yang; Youfang Lai; Huan Liu; Chenyang Shen; Yuncheng Zhong; Yiping Shao; Xinhua Li; Bob Liu; Xun Jia
Journal:  Phys Med Biol       Date:  2021-02-11       Impact factor: 3.609