Literature DB >> 33361559

Experimental and numerical studies on kV scattered x-ray imaging for real-time image guidance in radiation therapy.

Yanqi Huang1,2, Kai Yang3, Youfang Lai1,4, Huan Liu1,2, Chenyang Shen1,2, Yuncheng Zhong1,2, Yiping Shao2, Xinhua Li3, Bob Liu3, Xun Jia1,2.   

Abstract

Motion management is a critical component of image guided radiotherapy for lung cancer. We previously proposed a scheme using kV scattered x-ray photons for marker-less real-time image guidance in lung cancer radiotherapy. This study reports our recent progress using the photon counting detection technique to demonstrate potential feasibility of this method and using Monte Carlo (MC) simulations and ray-tracing calculations to characterize the performance. In our scheme, a thin slice of x-ray beam was directed to the target and we measured the outgoing scattered photons using a photon counting detector with a parallel-hole collimator to establish the correspondence between detector pixels and scatter positions. Image corrections of geometry, beam attenuation and scattering angle were performed to convert the raw image to the actual image of Compton attenuation coefficient. We set up a MC simulation system using an in-house developed GPU-based MC package modeling the image formation process. We also performed ray-tracing calculations to investigate the impacts of imaging system geometry on resulting image resolution. The experiment demonstrated feasibility of using a photon counting detector to measure scattered x-ray photons and generate the proposed scattered x-ray image. After correction, x-ray scattering image intensity and Compton scattering attenuation coefficient were linearly related, with R 2 greater than 0.9. Contrast to noise ratios of different objects were improved and the values in experimental results and MC simulation results agreed with each other. Ray-tracing calculations revealed the dependence of image resolution on imaging geometry. The image resolution increases with reduced source to object distance and increased collimator height. The study demonstrated potential feasibility of using scattered x-ray imaging as a real-time image guidance method in radiation therapy.

Entities:  

Mesh:

Year:  2021        PMID: 33361559      PMCID: PMC8283910          DOI: 10.1088/1361-6560/abd66c

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets.

Authors:  Gavin G Poludniowski
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

2.  On-board four-dimensional digital tomosynthesis: first experimental results.

Authors:  Jacqueline Maurer; Devon Godfrey; Zhiheng Wang; Fang-Fang Yin
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

3.  Fast internal marker tracking algorithm for onboard MV and kV imaging systems.

Authors:  W Mao; R D Wiersma; L Xing
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  Scatter imaging during lung stereotactic body radiation therapy characterized with phantom studies.

Authors:  Kevin C Jones; Julius Turian; Gage Redler; Gizem Cifter; John Strologas; Alistair Templeton; Damian Bernard; James C H Chu
Journal:  Phys Med Biol       Date:  2020-08-10       Impact factor: 3.609

5.  Kilovoltage intrafraction monitoring for prostate intensity modulated arc therapy: first clinical results.

Authors:  Jin Aun Ng; Jeremy T Booth; Per R Poulsen; Walther Fledelius; Esben Schjødt Worm; Thomas Eade; Fiona Hegi; Andrew Kneebone; Zdenka Kuncic; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-09-11       Impact factor: 7.038

6.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

7.  Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy.

Authors:  Tong Lin; Laura I Cerviño; Xiaoli Tang; Nuno Vasconcelos; Steve B Jiang
Journal:  Phys Med Biol       Date:  2009-01-16       Impact factor: 3.609

8.  The diaphragm as an anatomic surrogate for lung tumor motion.

Authors:  Laura I Cerviño; Alvin K Y Chao; Ajay Sandhu; Steve B Jiang
Journal:  Phys Med Biol       Date:  2009-05-15       Impact factor: 3.609

9.  Kilovoltage intrafraction motion monitoring and target dose reconstruction for stereotactic volumetric modulated arc therapy of tumors in the liver.

Authors:  Per Rugaard Poulsen; Esben S Worm; Jørgen B B Petersen; Cai Grau; Walther Fledelius; Morten Høyer
Journal:  Radiother Oncol       Date:  2014-07-02       Impact factor: 6.280

10.  Characterization of Compton-scatter imaging with an analytical simulation method.

Authors:  Kevin C Jones; Gage Redler; Alistair Templeton; Damian Bernard; Julius V Turian; James C H Chu
Journal:  Phys Med Biol       Date:  2018-01-11       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.