Literature DB >> 28079267

Estimating 4D-CBCT from prior information and extremely limited angle projections using structural PCA and weighted free-form deformation for lung radiotherapy.

Wendy Harris1, You Zhang1, Fang-Fang Yin1,2, Lei Ren1,2.   

Abstract

PURPOSE: To investigate the feasibility of using structural-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy.
METHODS: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion model extracted by a global PCA and free-form deformation (GMM-FD) technique, using a data fidelity constraint and deformation energy minimization. In this study, a new structural PCA method was developed to build a structural motion model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respiratory changes from planning 4D-CT to on-board volume to evaluate the method. The estimation accuracy was evaluated by the volume percent difference (VPD)/center-of-mass-shift (COMS) between lesions in the estimated and "ground-truth" on-board 4D-CBCT. Different on-board projection acquisition scenarios and projection noise levels were simulated to investigate their effects on the estimation accuracy. The method was also evaluated against three lung patients.
RESULTS: The SMM-WFD method achieved substantially better accuracy than the GMM-FD method for CBCT estimation using extremely small scan angles or projections. Using orthogonal 15° scanning angles, the VPD/COMS were 3.47 ± 2.94% and 0.23 ± 0.22 mm for SMM-WFD and 25.23 ± 19.01% and 2.58 ± 2.54 mm for GMM-FD among all eight XCAT scenarios. Compared to GMM-FD, SMM-WFD was more robust against reduction of the scanning angles down to orthogonal 10° with VPD/COMS of 6.21 ± 5.61% and 0.39 ± 0.49 mm, and more robust against reduction of projection numbers down to only 8 projections in total for both orthogonal-view 30° and orthogonal-view 15° scan angles. SMM-WFD method was also more robust than the GMM-FD method against increasing levels of noise in the projection images. Additionally, the SMM-WFD technique provided better tumor estimation for all three lung patients compared to the GMM-FD technique.
CONCLUSION: Compared to the GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles and low number of projections to provide fast low dose 4D target verification.
© 2017 American Association of Physicists in Medicine.

Entities:  

Keywords:  4D CBCT; free-form deformation; limited angle; motion modeling

Mesh:

Year:  2017        PMID: 28079267      PMCID: PMC5508535          DOI: 10.1002/mp.12102

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  32 in total

1.  X-ray scatter correction algorithm for cone beam CT imaging.

Authors:  Ruola Ning; Xiangyang Tang; David Conover
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

2.  Fast free-form deformable registration via calculus of variations.

Authors:  Weiguo Lu; Ming-Li Chen; Gustavo H Olivera; Kenneth J Ruchala; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2004-07-21       Impact factor: 3.609

3.  Accelerating reconstruction of reference digital tomosynthesis using graphics hardware.

Authors:  Hui Yan; Lei Ren; Devon J Godfrey; Fang-Fang Yin
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

4.  Feasibility study of a synchronized-moving-grid (SMOG) system to improve image quality in cone-beam computed tomography (CBCT).

Authors:  Lei Ren; Fang-Fang Yin; Indrin J Chetty; David A Jaffray; Jian-Yue Jin
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

5.  Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling.

Authors:  Jun Lu; Thomas M Guerrero; Peter Munro; Andrew Jeung; Pai-Chun M Chi; Peter Balter; X Ronald Zhu; Radhe Mohan; Tinsu Pan
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

6.  Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids.

Authors:  Lei Ren; Yingxuan Chen; You Zhang; William Giles; Jianyue Jin; Fang-Fang Yin
Journal:  Technol Cancer Res Treat       Date:  2015-05-24

7.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

8.  High-quality four-dimensional cone-beam CT by deforming prior images.

Authors:  Jing Wang; Xuejun Gu
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

9.  Stereotactic ablative radiotherapy for early stage non-small cell lung cancer: a word of caution.

Authors:  Gonzalo Varela; María Teresa Gómez-Hernández
Journal:  Transl Lung Cancer Res       Date:  2016-02

10.  Evaluation of the effect of respiratory and anatomical variables on a Fourier technique for markerless, self-sorted 4D-CBCT.

Authors:  I Vergalasova; J Cai; W Giles; W P Segars; F F Yin
Journal:  Phys Med Biol       Date:  2013-09-24       Impact factor: 3.609

View more
  14 in total

1.  A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT.

Authors:  Wendy Harris; Chunhao Wang; Fang-Fang Yin; Jing Cai; Lei Ren
Journal:  Med Phys       Date:  2018-06-13       Impact factor: 4.071

2.  Augmentation of CBCT Reconstructed From Under-Sampled Projections Using Deep Learning.

Authors:  Zhuoran Jiang; Yingxuan Chen; Yawei Zhang; Yun Ge; Fang-Fang Yin; Lei Ren
Journal:  IEEE Trans Med Imaging       Date:  2019-04-23       Impact factor: 10.048

3.  Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy.

Authors:  Yawei Zhang; Fang-Fang Yin; You Zhang; Lei Ren
Journal:  Phys Med Biol       Date:  2017-03-24       Impact factor: 3.609

4.  Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study.

Authors:  Yingxuan Chen; Fang-Fang Yin; Yawei Zhang; You Zhang; Lei Ren
Journal:  Phys Med Biol       Date:  2018-04-19       Impact factor: 3.609

5.  Image acquisition optimization of a limited-angle intrafraction verification (LIVE) system for lung radiotherapy.

Authors:  Yawei Zhang; Xinchen Deng; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2017-11-30       Impact factor: 4.071

6.  First clinical retrospective investigation of limited projection CBCT for lung tumor localization in patients receiving SBRT treatment.

Authors:  Yawei Zhang; Fang-Fang Yin; Lei Ren
Journal:  Phys Med Biol       Date:  2019-05-08       Impact factor: 3.609

7.  Prior image-guided cone-beam computed tomography augmentation from under-sampled projections using a convolutional neural network.

Authors:  Zhuoran Jiang; Zeyu Zhang; Yushi Chang; Yun Ge; Fang-Fang Yin; Lei Ren
Journal:  Quant Imaging Med Surg       Date:  2021-12

8.  Real-time Markerless Tracking of Lung Tumors based on 2-D Fluoroscopy Imaging using Convolutional LSTM.

Authors:  Tengya Peng; Zhuoran Jiang; Yushi Chang; Lei Ren
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-11-13

9.  Enhancement of 4-D Cone-Beam Computed Tomography (4D-CBCT) Using a Dual-Encoder Convolutional Neural Network (DeCNN).

Authors:  Zhuoran Jiang; Zeyu Zhang; Yushi Chang; Yun Ge; Fang-Fang Yin; Lei Ren
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-12-07

10.  Enhancing digital tomosynthesis (DTS) for lung radiotherapy guidance using patient-specific deep learning model.

Authors:  Zhuoran Jiang; Fang-Fang Yin; Yun Ge; Lei Ren
Journal:  Phys Med Biol       Date:  2021-01-26       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.