Literature DB >> 18762111

Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit.

Jonathan E Buzzell1, Douglas R Weikert, Jeffry T Watson, Donald H Lee.   

Abstract

PURPOSE: To compare distal radius volar fixed-angle plates for anatomic fit.
METHODS: Twenty embalmed radii were stripped of soft tissues. The volar lip (watershed line) on the volar distal radius served as a reference line. Seven volar fixed-angle plates were tested (Acumed Acu-loc Standard, Hand Innovations DVRAW and DVRAN, Synthes Juxta-articular [JA], Synthes Extra-articular [EA], Trimed Volar Bearing, Zimmer Volar Lateral Column). Four parameters of anatomic fit were studied: (1) site of best fit; (2) percent plate contact; (3) pin-subchondral bone distance; and (4) extraosseous penetrations. The Wilcoxon signed rank test and Pearson's correlation coefficient were used to compare interobserver plate placement. A Kruskal-Wallis analysis of variance was used to compare percent plate contact and pin-subchondral bone distance across all plates. The Bonferroni correction for multiple comparisons was used to compare pin-subchondral bone distances for all possible plate combinations.
RESULTS: There was no difference between observers for plate placement. Each plate had a specific site of best fit, and the 7 plates varied widely in best fit location. Percent contact (range, 3% to 6%) between plates was significantly different. Pin-subchondral bone distance across all plates was significantly different. Analysis of all possible plate combinations showed that the Synthes EA pin-subchondral bone distances were significantly different than those of all plates except Zimmer. Amongst the 140 plate insertions, the radiocarpal joint was penetrated in 17, the styloid in 7, (with 6 associated with the DVRAW plate), and the distal radioulnar joint in 9 (all associated with the DVRAW plate).
CONCLUSIONS: There was considerable variation in ideal plate location among the 7 plates tested. Total contact was minimal for all plates tested. The Synthes EA pin-subchondral bone distance was significantly greater than those of other plates tested. Joint penetration was relatively common, necessitating use of fluoroscopy and proper plate width.

Entities:  

Mesh:

Year:  2008        PMID: 18762111     DOI: 10.1016/j.jhsa.2008.02.029

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  16 in total

1.  The cadaveric anatomy of the distal radius: implications for the use of volar plates.

Authors:  P A McCann; D Clarke; R Amirfeyz; R Bhatia
Journal:  Ann R Coll Surg Engl       Date:  2012-03       Impact factor: 1.891

2.  Anatomical and radiological study applied to distal radius surgery.

Authors:  N Gasse; D Lepage; R Pem; C Bernard; J M Lerais; P Garbuio; L Obert
Journal:  Surg Radiol Anat       Date:  2010-12-07       Impact factor: 1.246

3.  Impact of Design on Force between Flexor Tendons and Distal Radius Volar Plates.

Authors:  Katharine M Hinchcliff; Ido Volk; Xenia Ivanova; Sandra Taylor; Robert M Szabo
Journal:  J Wrist Surg       Date:  2019-03-25

4.  Females Are Not Proportionally Smaller Males: Relationships Between Radius Anthropometrics and Their Sex Differences.

Authors:  Mitchell L Thom; Katherine Willmore; Alexandra Surugiu; Emily Lalone; Timothy A Burkhart
Journal:  Hand (N Y)       Date:  2019-02-28

5.  Surgical approaches to the distal radius.

Authors:  Asif M Ilyas
Journal:  Hand (N Y)       Date:  2010-06-22

6.  The treatment of distal radius articular fractures of C1-C2 type with DVR plate: analysis of 40 cases.

Authors:  L Tarallo; R Adani; R Mugnai; F Catani
Journal:  Musculoskelet Surg       Date:  2011-05-26

7.  Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model.

Authors:  Kousuke Iba; Yasuhiro Ozasa; Takuro Wada; Tomoaki Kamiya; Toshihiko Yamashita; Mitsuhiro Aoki
Journal:  J Orthop Surg Res       Date:  2010-12-02       Impact factor: 2.359

8.  Volar Locking Plate Fixations for Displaced Distal Radius Fractures: An Evaluation of Complications and Radiographic Outcomes.

Authors:  James Wilson; Jeremy J Viner; Kavan S Johal; Michael J Woodruff
Journal:  Hand (N Y)       Date:  2017-07-09

9.  The Watershed Line of the Distal Radius: Cadaveric and Imaging Study of Anatomical Landmarks.

Authors:  Minke Bergsma; Job N Doornberg; Annelise Borghorst; W A Kernkamp; R L Jaarsma; Gregory I Bain
Journal:  J Wrist Surg       Date:  2019-12-20

10.  Interpretations of the Term "Watershed Line" Used as Reference for Volar Plating.

Authors:  Minke Bergsma; Job N Doornberg; Laurent Hendrickx; Batur Hayat; Gino M M J Kerkhoffs; Bhavin Jhadav; Ruurd L Jaarsma; Gregory I Bain
Journal:  J Wrist Surg       Date:  2019-08-13
View more