Literature DB >> 31404222

Impact of Design on Force between Flexor Tendons and Distal Radius Volar Plates.

Katharine M Hinchcliff1, Ido Volk2, Xenia Ivanova2, Sandra Taylor3, Robert M Szabo2.   

Abstract

Background  Flexor tendon injury is a rare but serious complication of distal radius volar plating. Purpose  This study aims to determine whether the design of distal radius volar plates impacts the amount of force exerted on the flexor digitorum profundus (FDP) and flexor pollicis longus (FPL) tendons when the plates are placed proximal and distal to the watershed line. Methods  Three commercially available plates were applied to 10 fresh, matched-pair upper extremity specimens. Cyclical loading was applied to the tendons, and the force generated between tendon and plate was measured. Linear mixed effect models were used to evaluate differences in maximum and mean forces by plate position, plate design, and the interaction between position and design. Results  Forces on the tendons differed significantly by position but not plate design. For the FPL tendon, the average maximum force with a plate in Soong's grade 2 was 4.50 (95% confidence interval [CI]: 2.8-7.3) times higher than when the plate was in a Soong's grade 0 placement, and 4.63 (95% CI: 2.82-7.61) times higher for the FDP tendon. While not statistically significant, lower observed force values with thinner plates when plates were placed distal to the watershed line suggest that that plate thickness could also be a critical plate characteristic for distally placed plates. Conclusion  Despite differences in plate design, the main determinant of plate prominence and therefore flexor tendon injury potential is placement in relation to the watershed line. Clinical Relevance  This study may help to guide surgeon implant selection and volar plate design.

Entities:  

Keywords:  distal radius fracture; distal radius volar plate; flexor tendon injury; tendon rupture; watershed line

Year:  2019        PMID: 31404222      PMCID: PMC6685735          DOI: 10.1055/s-0039-1683845

Source DB:  PubMed          Journal:  J Wrist Surg        ISSN: 2163-3916


  29 in total

1.  The frequency and epidemiology of hand and forearm fractures in the United States.

Authors:  K C Chung; S V Spilson
Journal:  J Hand Surg Am       Date:  2001-09       Impact factor: 2.230

2.  Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit.

Authors:  Jonathan E Buzzell; Douglas R Weikert; Jeffry T Watson; Donald H Lee
Journal:  J Hand Surg Am       Date:  2008-09       Impact factor: 2.230

3.  Volar locking plate implant prominence and flexor tendon rupture.

Authors:  Maximillian Soong; Brandon E Earp; Gavin Bishop; Albert Leung; Philip Blazar
Journal:  J Bone Joint Surg Am       Date:  2011-01-14       Impact factor: 5.284

4.  The treatment of unstable distal radius fractures with volar fixation.

Authors:  J L Orbay
Journal:  Hand Surg       Date:  2000-12

5.  Predictors of functional outcomes after surgical treatment of distal radius fractures.

Authors:  Kevin C Chung; Sandra V Kotsis; H Myra Kim
Journal:  J Hand Surg Am       Date:  2007-01       Impact factor: 2.230

6.  Fracture of the distal radius: risk factors for complications after locked volar plate fixation.

Authors:  Maximillian Soong; Roderick van Leerdam; Thierry G Guitton; Christopher Got; Julia Katarincic; David Ring
Journal:  J Hand Surg Am       Date:  2011-01       Impact factor: 2.230

7.  The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model.

Authors:  Stefano M Sinicropi; Brian W Su; Frank J Raia; May Parisien; Robert J Strauch; Melvin P Rosenwasser
Journal:  J Hand Surg Am       Date:  2005-03       Impact factor: 2.230

8.  Prediction of instability in distal radial fractures.

Authors:  P J Mackenney; M M McQueen; R Elton
Journal:  J Bone Joint Surg Am       Date:  2006-09       Impact factor: 5.284

9.  Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures.

Authors:  M Al-Rashid; K Theivendran; M A C Craigen
Journal:  J Bone Joint Surg Br       Date:  2006-12

10.  Coverage of distal radius internal fixation and wrist fusion devices with AlloDerm.

Authors:  Peter L Althausen; Robert M Szabo
Journal:  Tech Hand Up Extrem Surg       Date:  2004-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.