The aim of this investigation was to evaluate the efficiency of fixed angle plates DVR in the treatment of C1 and C2 type articular wrist fractures according to the AO classification. From July 2005 to March 2009, 40 wrist fractures were treated: 18 were of C1 type while 22 of C2 type according to AO classification. The age of patients varied from 25 to 79 years old. The average length of follow-up was 17 months (range, 4-37 months). The average articular motility was flexion 59.4° and extension 62.7°. Final radiographic parameters were of 18.7° of average ulnar inclination, 10.3° of average dorsal inclination, and 1.45 mm of negative ulnar variance. All patients were reassessed according to Mayo Modified Wrist Score getting a very good/good result in 82% of cases and a medium/poor one in 18%. The DASH score pulled off 46.3 points in the first group, 5.1 in the second group, and 6 in the third one. The statistical analysis based on Student's t test showed how C1 and C2 classification did not influence the results using the same treatment. DVR plate showed a very good reliability and a sufficient stability with both C1 and C2 fractures.

Entities:  

Mesh:

Year:  2011        PMID: 21614597     DOI: 10.1007/s12306-011-0140-9

Source DB:  PubMed          Journal:  Musculoskelet Surg        ISSN: 2035-5114


  23 in total

1.  The extended flexor carpi radialis approach: a new perspective for the distal radius fracture.

Authors:  J L Orbay; A Badia; I R Indriago; A Infante; R K Khouri; E Gonzalez; D L Fernandez
Journal:  Tech Hand Up Extrem Surg       Date:  2001-12

2.  Augmented external fixation of unstable distal radius fractures.

Authors:  W H Seitz; A I Froimson; R Leb; J D Shapiro
Journal:  J Hand Surg Am       Date:  1991-11       Impact factor: 2.230

3.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

4.  Colles fracture: does the anatomical result affect the final function?

Authors:  M McQueen; J Caspers
Journal:  J Bone Joint Surg Br       Date:  1988-08

5.  Fixed angle fixation of distal radius fractures through a minimally invasive approach.

Authors:  Jorge L Orbay; Amel Touhami; Carolina Orbay
Journal:  Tech Hand Up Extrem Surg       Date:  2005-09

6.  External fixation of distal radial fractures.

Authors:  W P Cooney
Journal:  Clin Orthop Relat Res       Date:  1983-11       Impact factor: 4.176

7.  Open reduction and internal fixation of displaced intraarticular fractures of the distal radius. 31 patients followed for 3-7 years.

Authors:  L M Hove; P T Nilsen; O Furnes; H E Oulie; E Solheim; A O Mölster
Journal:  Acta Orthop Scand       Date:  1997-02

8.  Fractures of the distal radius. Intermediate and end results in relation to radiologic parameters.

Authors:  M Porter; I Stockley
Journal:  Clin Orthop Relat Res       Date:  1987-07       Impact factor: 4.176

Review 9.  Distal radius fractures: current concepts.

Authors:  Mark H Henry
Journal:  J Hand Surg Am       Date:  2008-09       Impact factor: 2.230

10.  Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study.

Authors:  Denju Osada; Steven F Viegas; Munir A Shah; Randal P Morris; Rita M Patterson
Journal:  J Hand Surg Am       Date:  2003-01       Impact factor: 2.230

View more
  3 in total

1.  Functional Outcome and Complications at 2.5 Years Following Volar Locking Plate Fixation of Distal Radius Fractures.

Authors:  Robert J MacFarlane; David Miller; Lynn Wilson; Carl Meyer; Cronan Kerin; David James Ford; Graham Cheung
Journal:  J Hand Microsurg       Date:  2015-01-27

2.  Volar locking plate removal after distal radius fracture: a 10-year retrospective study.

Authors:  Jun-Ku Lee; Younghun Lee; Choongki Kim; Minwook Kim; Soo-Hong Han
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-29       Impact factor: 3.067

3.  A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases.

Authors:  Luigi Tarallo; Raffaele Mugnai; Roberto Adani; Francesco Zambianchi; Fabio Catani
Journal:  J Orthop Traumatol       Date:  2014-07-15
  3 in total