Literature DB >> 28691543

Volar Locking Plate Fixations for Displaced Distal Radius Fractures: An Evaluation of Complications and Radiographic Outcomes.

James Wilson1, Jeremy J Viner1, Kavan S Johal1, Michael J Woodruff1.   

Abstract

BACKGROUND: A volar locking plate (VLP) is the most frequently used form of implant used for open reduction and internal fixation of distal radius fractures. They are known to have a complication rate of up to 27%. We hypothesized that plate design could influence complication rates.
METHODS: We performed a review of patients undergoing VLP fixation for distal radius fracture. A total of 228 patients underwent fixation with the Distal Volar Radial Anatomical (DVR) plate; 388 patients underwent fixation with the VariAx plate. Independent observers performed blinded case note and radiographic review, to assess for the quality of reduction, and complications for the inserted VLP.
RESULTS: Mean time to surgery was 6.0 days; mean follow-up was 17.5 weeks. Mean age was 56.5 years. The quality of reduction was classified as anatomical (46%), good (36.3%), moderate (13.0%), or poor (3.9%). Complications were identified in 109 patients (17%). Plate prominence was seen in 133 patients (21%). The DVR plate was less prominent ( P < .001) and had better overall radiographic appearances ( P = .025). Flexor tendon complications were related to plate prominence ( P = .005). Inferior reduction was associated with increased time to surgery ( P = .020).
CONCLUSIONS: This study highlights the importance of prompt surgery, effective fracture reduction, and careful plate positioning to avoid volar prominence.

Entities:  

Keywords:  complications; distal radius fracture; tendon rupture; volar plating

Mesh:

Year:  2017        PMID: 28691543      PMCID: PMC6081777          DOI: 10.1177/1558944717717505

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  27 in total

Review 1.  What are the radiological predictors of functional outcome following fractures of the distal radius?

Authors:  C Y Ng; M M McQueen
Journal:  J Bone Joint Surg Br       Date:  2011-02

2.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

3.  Fractures of the distal end of radius in elderly patients: a comparative study of anatomical and functional results.

Authors:  Koji Fujii; Tatsuhiko Henmi; Yoshiji Kanematsu; Takuya Mishiro; Toshinori Sakai; Tomoya Terai
Journal:  J Orthop Surg (Hong Kong)       Date:  2002-06       Impact factor: 1.118

4.  An anatomical study of the watershed line on the volar, distal aspect of the radius: implications for plate placement and avoidance of tendon ruptures.

Authors:  Junya Imatani; Keiichi Akita; Kumiko Yamaguchi; Hirotaka Shimizu; Hidenori Kondou; Toshifumi Ozaki
Journal:  J Hand Surg Am       Date:  2012-08       Impact factor: 2.230

5.  Fracture of the distal radius: risk factors for complications after locked volar plate fixation.

Authors:  Maximillian Soong; Roderick van Leerdam; Thierry G Guitton; Christopher Got; Julia Katarincic; David Ring
Journal:  J Hand Surg Am       Date:  2011-01       Impact factor: 2.230

6.  Volar versus dorsal plating in the management of intra-articular distal radius fractures.

Authors:  David S Ruch; Anastasios Papadonikolakis
Journal:  J Hand Surg Am       Date:  2006-01       Impact factor: 2.230

7.  Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study.

Authors:  Corey Trease; Terence McIff; E Bruce Toby
Journal:  J Hand Surg Am       Date:  2005-07       Impact factor: 2.230

8.  Patient-perceived outcome after displaced distal radius fractures. A comparison between radiological parameters, objective physical variables, and the DASH score.

Authors:  Maria K T Wilcke; Hassan Abbaszadegan; Per Y Adolphson
Journal:  J Hand Ther       Date:  2007 Oct-Dec       Impact factor: 1.950

9.  Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

10.  Incidence and clinical outcomes of tendon rupture following distal radius fracture.

Authors:  Brian D White; Jason A Nydick; Dawnne Karsky; Bailee D Williams; Alfred V Hess; Jeffrey D Stone
Journal:  J Hand Surg Am       Date:  2012-09-01       Impact factor: 2.230

View more
  6 in total

1.  Older Patient Preferences for Internal Fixation after a Distal Radius Fracture: A Qualitative Study from the Wrist and Radius Injury Surgical Trial.

Authors:  Jacob S Nasser; Helen E Huetteman; Melissa J Shauver; Kevin C Chung
Journal:  Plast Reconstr Surg       Date:  2018-07       Impact factor: 4.730

2.  The Watershed Line of the Distal Radius: Cadaveric and Imaging Study of Anatomical Landmarks.

Authors:  Minke Bergsma; Job N Doornberg; Annelise Borghorst; W A Kernkamp; R L Jaarsma; Gregory I Bain
Journal:  J Wrist Surg       Date:  2019-12-20

3.  Interpretations of the Term "Watershed Line" Used as Reference for Volar Plating.

Authors:  Minke Bergsma; Job N Doornberg; Laurent Hendrickx; Batur Hayat; Gino M M J Kerkhoffs; Bhavin Jhadav; Ruurd L Jaarsma; Gregory I Bain
Journal:  J Wrist Surg       Date:  2019-08-13

4.  Outcomes following Distal Radius Fractures with Preexisting Ulnocarpal Abutment.

Authors:  Richard Samade; Nolan Farrell; Omar Zaki; Nicholas Farrar; Kanu S Goyal
Journal:  J Wrist Surg       Date:  2021-03-24

Review 5.  SAFETY AND RELIABILITY OF CARBON-PEEK PLATE FOR THE TREATMENT OF DISTAL RADIUS FRACTURES: A REVIEW OF THE LITERATURE.

Authors:  Michela Saracco; Camillo Fulchignoni; Calogero Velluto; Lorenzo Rocchi
Journal:  Orthop Rev (Pavia)       Date:  2021-09-22

6.  Peri-Implant Distal Radius Fracture: Proposal of a New Classification.

Authors:  Leonardo Stramazzo; Giuseppe Rovere; Alessio Cioffi; Giulio Edoardo Vigni; Nicolò Galvano; Antonio D'Arienzo; Giulia Letizia Mauro; Lawrence Camarda; Michele D'Arienzo
Journal:  J Clin Med       Date:  2022-05-07       Impact factor: 4.241

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.