Literature DB >> 18751856

Early dislocation rate in ceramic-on-ceramic total hip arthroplasty.

Kenny Mai1, Mary E Hardwick, Richard H Walker, Steven N Copp, Kace A Ezzet, Clifford W Colwell.   

Abstract

Wear debris from metal-on-polyethylene articulation in conventional total hip arthroplasty (THA) may limit THA longevity. Bearing surfaces made of modern ceramic material, with high wear resistance and low fracture risk, have the potential to extend the longevity of THA and make the procedure more suitable for young, active patients. Concerns regarding a ceramic-on-ceramic bearing surface have included potential for a higher incidence of dislocation caused by limited modular neck length and liner options. This prospective study assessed the early dislocation incidence for a ceramic-on-ceramic THA system. Out of the 336 consecutive ceramic-on-ceramic THA performed at our institution over an 8-year (1997-2005) period, 2 (0.6%) sustained dislocation during, and none after, the first postoperative year. Both dislocations were treated with closed reduction. No component fracture or revision for any reason has occurred in this series.

Entities:  

Year:  2008        PMID: 18751856      PMCID: PMC2504286          DOI: 10.1007/s11420-007-9060-5

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  21 in total

Review 1.  Evolution of alumina-on-alumina implants: a review.

Authors:  L Sedel
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

2.  Effect of posterior capsular repair on early dislocation in primary total hip replacement.

Authors:  R E White; T J Forness; J K Allman; D W Junick
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

3.  Hip mechanics after posterior structure repair in total hip arthroplasty.

Authors:  William M Mihalko; Leo A Whiteside
Journal:  Clin Orthop Relat Res       Date:  2004-03       Impact factor: 4.176

Review 4.  Concerns about ceramics in THA.

Authors:  Robert L Barrack; Corey Burak; Harry B Skinner
Journal:  Clin Orthop Relat Res       Date:  2004-12       Impact factor: 4.176

Review 5.  Ceramics in total hip replacement.

Authors:  Didier Hannouche; Moussa Hamadouche; Rémy Nizard; Pascal Bizot; Alain Meunier; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2005-01       Impact factor: 4.176

6.  An analysis of the risk of hip dislocation with a contemporary total joint registry.

Authors:  Monti Khatod; Thomas Barber; Elizabeth Paxton; Robert Namba; Donald Fithian
Journal:  Clin Orthop Relat Res       Date:  2006-06       Impact factor: 4.176

7.  Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty.

Authors:  Daniel J Berry; Marius von Knoch; Cathy D Schleck; William S Harmsen
Journal:  J Bone Joint Surg Am       Date:  2005-11       Impact factor: 5.284

Review 8.  Ceramic femoral head retrieval data.

Authors:  G Willmann
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

9.  Modern ceramic-on-ceramic total hip systems in the United States: early results.

Authors:  J P Garino
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

10.  Dislocations after total hip arthroplasty.

Authors:  R Y Woo; B F Morrey
Journal:  J Bone Joint Surg Am       Date:  1982-12       Impact factor: 5.284

View more
  3 in total

1.  Bony impingement limits design-related increases in hip range of motion.

Authors:  Adam Bunn; Clifford W Colwell; Darryl D D'Lima
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Сomparative analysis of large diameter bearing ceramic monoblock acetabular components.

Authors:  Valery Yu Murylev; Pavel M Elizarov; Aleksei V Muzychenkov; Yaroslav A Rukin; Grigory A Kukovenko; Semen S Alekseev; Michail P Elizarov
Journal:  J Orthop       Date:  2022-08-11

3.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.