Excessive polyethylene debris generated from a total hip arthroplasty can lead to osteolysis and premature revision. Most of this polyethylene debris comes from the concave articulation. However, abrasive wear on the convex side of a modular polyethylene component also may play a role in this problem. Motion of a modular polyethylene liner with respect to its shell can lead to such abrasive wear. Six samples of modular acetabular components from eight manufacturers were tested for motion between the shell and the liner. Motion at the shell liner interface was detected by five fiberoptic sensors in the x, y, and z planes. Micromotion occurred at the shell liner interface in all designs tested. The magnitude of motion varied between manufacturers, ranging from 5 to 311 microns. Design features that limit motion may be advantageous in limiting the amount of polyethylene debris.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10546629

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

1.  Aseptic loosening of total hip replacement presenting as an anterior thigh mass.

Authors:  Ravindra Gudena; Suma Kuna; Nikhil Pradhan
Journal:  Musculoskelet Surg       Date:  2011-10-09

2.  Early follow-up for a hybrid total hip arthroplasty using a metal-backed acetabular component designed to reduce "backside" polyethylene wear.

Authors:  Colin E Poole; Shantanu S Patil; Darryl D D'Lima; Clifford W Colwell
Journal:  HSS J       Date:  2005-09

3.  Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners.

Authors:  Kamal Bali; Richard W McCalden; Douglas D R Naudie; Steven J MacDonald; Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

4.  Survivorship of monoblock trabecular metal cups in primary THA : midterm results.

Authors:  Konstantinos N Malizos; Konstantinos Bargiotas; Loukia Papatheodorou; Michael Hantes; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

5.  Direct comparison of polyethylene wear in cemented and uncemented acetabular cups.

Authors:  Håvard Bjerkholt; Oystein Høvik; Olav Reikerås
Journal:  J Orthop Traumatol       Date:  2010-09-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.