Delayed migration of a self-expanding intracranial microstent.

M E Kelly1, R D Turner, S I Moskowitz, V Gonugunta, M S Hussain, D Fiorella.   

Abstract

A 43-year-old patient with a basilar apex aneurysm had a 4.5-mm x 14-mm Enterprise stent placed from the midbasilar artery to the left P1 segment of the posterior cerebral artery. The patient experienced vertigo 4 months after stent placement and 1 week after stopping clopidogrel. At 5 months postembolization, angiography showed stent migration into the proximal basilar artery. This is the first described case of the spontaneous delayed migration of a self-expanding intracranial microstent.

Entities:  

Mesh:

Year:  2008        PMID: 18719038      PMCID: PMC8118926          DOI: 10.3174/ajnr.A1224

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  4 in total

1.  Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms.

Authors:  Gádor Cantón; David I Levy; Juan C Lasheras; Peter K Nelson
Journal:  J Neurosurg       Date:  2005-11       Impact factor: 5.115

2.  Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3-6-mo) follow-up.

Authors:  David Fiorella; Felipe C Albuquerque; Vivek R Deshmukh; Cameron G McDougall
Journal:  Neurosurgery       Date:  2005-06       Impact factor: 4.654

3.  Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms.

Authors:  David Fiorella; Felipe C Albuquerque; Patrick Han; Cameron G McDougall
Journal:  Neurosurgery       Date:  2004-01       Impact factor: 4.654

4.  Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils.

Authors:  Ronald P Benitez; Marco T Silva; Jack Klem; Erol Veznedaroglu; Robert H Rosenwasser
Journal:  Neurosurgery       Date:  2004-06       Impact factor: 4.654

  4 in total
  18 in total

Review 1.  Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents.

Authors:  Markus Tremmel; Jianping Xiang; Sabareesh K Natarajan; L Nelson Hopkins; Adnan H Siddiqui; Elad I Levy; Hui Meng
Journal:  World Neurosurg       Date:  2010 Aug-Sep       Impact factor: 2.104

2.  Possible mechanisms for delayed migration of the closed cell--designed enterprise stent when used in the adjunctive treatment of a basilar artery aneurysm.

Authors:  B Gao; A M Malek
Journal:  AJNR Am J Neuroradiol       Date:  2010-09-30       Impact factor: 3.825

3.  Another delayed migration of an enterprise stent.

Authors:  G J Rodriguez; A Maud; R A Taylor
Journal:  AJNR Am J Neuroradiol       Date:  2009-02-04       Impact factor: 3.825

4.  Parent vessel size and curvature strongly influence risk of incomplete stent apposition in enterprise intracranial aneurysm stent coiling.

Authors:  R S Heller; A M Malek
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-04       Impact factor: 3.825

5.  Endovascular retrieval of a prematurely deployed covered stent.

Authors:  Jefferson T Miley; Gustavo J Rodriguez; Ramachandra P Tummala
Journal:  World J Radiol       Date:  2015-06-28

6.  Stent/balloon combination assist technique for wide-necked basilar terminal aneurysms.

Authors:  Shigeru Miyachi; Noriaki Matsubara; Takashi Izumi; Takumi Asai; Takashi Yamanouchi; Keisuke Ota; Keiko Oda; Toshihiko Wakabayashi
Journal:  Interv Neuroradiol       Date:  2013-09-26       Impact factor: 1.610

7.  The enterprise stent for the treatment of intracranial aneurysms: stenting strategies.

Authors:  Horst Urbach; Henriette Tschampa; Attila Kovács; Susanne Greschus; Johannes Schramm
Journal:  Klin Neuroradiol       Date:  2009-08-23

8.  First Experiences with the New Enterprise2® Stent.

Authors:  C Herweh; S Nagel; J Pfaff; C Ulfert; M Wolf; M Bendszus; M Möhlenbruch
Journal:  Clin Neuroradiol       Date:  2016-09-27       Impact factor: 3.649

9.  Coil embolization of anterior circulation aneurysms supported by the Solitaire AB Neurovascular Remodeling Device.

Authors:  Joachim Klisch; Christin Clajus; Vojtech Sychra; Cornelia Eger; Christoph Strasilla; Steffen Rosahl; Rüdiger Gerlach; Ingrid Bär; Heinrich Hoch; Uta Herbon; Ljubisa Borota; Per Jonasson; Thomas Liebig
Journal:  Neuroradiology       Date:  2009-07-31       Impact factor: 2.804

10.  Spontaneous delayed migration/shortening of the pipeline embolization device: report of 5 cases.

Authors:  N Chalouhi; S I Tjoumakaris; L F Gonzalez; D Hasan; P J Pema; G Gould; R H Rosenwasser; P M Jabbour
Journal:  AJNR Am J Neuroradiol       Date:  2013-06-27       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.