Literature DB >> 26120384

Endovascular retrieval of a prematurely deployed covered stent.

Jefferson T Miley1, Gustavo J Rodriguez1, Ramachandra P Tummala1.   

Abstract

Several techniques have been reported to address different endovascular device failures. We report the case of a premature deployment of a covered balloon mounted stent during endovascular repair of a post-traumatic carotid-cavernous fistula (CCF). A 50-year-old male suffered a fall resulting in loss of consciousness and multiple facial fractures. Five weeks later, he developed decreased left visual acuity, proptosis, chemosis, limited eye movements and cranial/orbit bruit. Cerebral angiography demonstrated a direct left CCF and endovascular repair with a 5.0 mm × 19 mm covered stent was planned. Once in the lacerum segment, increased resistance was encountered and the stent was withdrawn resulting in premature deployment. A 3 mm × 9 mm balloon was advanced over an exchange length microwire and through the stent lumen. Once distal to the stent, the balloon was inflated and slowly pulled back in contact with the stent. All devices were successfully withdrawn as a unit. The use of a balloon to retrieve a prematurely deployed balloon mounted stent is a potential rescue option if leaving the stent in situ carries risks.

Entities:  

Keywords:  Covered stent; Premature stent deployment; Stent retrieval

Year:  2015        PMID: 26120384      PMCID: PMC4473308          DOI: 10.4329/wjr.v7.i6.139

Source DB:  PubMed          Journal:  World J Radiol        ISSN: 1949-8470


  23 in total

1.  Successful retrieval of intracoronary lost balloon-mounted stent using a small balloon.

Authors:  S Qiao; R Gao; J Chen; M Yao; Y Yang; X Qin; B Xu
Journal:  Chin Med J (Engl)       Date:  2000-01       Impact factor: 2.628

2.  Retrieval of a displaced detachable coil and intracranial stent with an L5 Merci Retriever during endovascular embolization of an intracranial aneurysm.

Authors:  Nirav Vora; Ajith Thomas; Anand Germanwala; Tudor Jovin; Michael Horowitz
Journal:  J Neuroimaging       Date:  2008-01       Impact factor: 2.486

3.  Preliminary experience with the enterprise stent for endovascular treatment of complex intracranial aneurysms: potential advantages and limiting characteristics.

Authors:  Boris Lubicz; Olivier François; Marc Levivier; Jacques Brotchi; Danielle Balériaux
Journal:  Neurosurgery       Date:  2008-05       Impact factor: 4.654

4.  Snare extraction of a fractured coronary stent in a saphenous vein graft.

Authors:  Daniel H Steinberg; Lowell F Satler; Augusto D Pichard
Journal:  Catheter Cardiovasc Interv       Date:  2007-08-01       Impact factor: 2.692

5.  Traumatic carotid artery-cavernous sinus fistula treated with a covered stent. Report of two cases.

Authors:  Anoop Madan; Asim Mujic; Katie Daniels; Andrew Hunn; John Liddell; Jeffrey V Rosenfeld
Journal:  J Neurosurg       Date:  2006-06       Impact factor: 5.115

6.  Coronary and systemic stent embolization during percutaneous coronary interventions: a single center experience.

Authors:  A Yucel Colkesen; Mehmet Baltali; Tayfun Acil; Goknur Tekin; Abdullah Tekin; Tansel Erol; Alpay T Sezgin; Haldun Muderrisoglu
Journal:  Int Heart J       Date:  2007-03       Impact factor: 1.862

7.  Angiographic follow-up of traumatic carotid cavernous fistulas treated with endovascular stent graft placement.

Authors:  E Archondakis; G Pero; L Valvassori; E Boccardi; G Scialfa
Journal:  AJNR Am J Neuroradiol       Date:  2007-02       Impact factor: 3.825

8.  Long-term follow-up in patients with lost coronary stents during interventional procedures.

Authors:  Juergen Kammler; Franz Leisch; Klaus Kerschner; Alexander Kypta; Clemens Steinwender; Heinz Kratochwill; Thomas Lukas; Robert Hofmann
Journal:  Am J Cardiol       Date:  2006-06-12       Impact factor: 2.778

9.  Placement of covered stents for the treatment of direct carotid cavernous fistulas.

Authors:  C Wang; X Xie; C You; C Zhang; M Cheng; M He; H Sun; B Mao
Journal:  AJNR Am J Neuroradiol       Date:  2009-04-02       Impact factor: 3.825

10.  Classification and treatment of spontaneous carotid-cavernous sinus fistulas.

Authors:  D L Barrow; R H Spector; I F Braun; J A Landman; S C Tindall; G T Tindall
Journal:  J Neurosurg       Date:  1985-02       Impact factor: 5.115

View more
  3 in total

1.  Solitaire Stentectomy Using a Stent-Retriever Technique in a Porcine Model.

Authors:  Andreas Simgen; Michael Kettner; Frida Juliane Webelsiep; Toshiki Tomori; Ruben Mühl-Benninghaus; Umut Yilmaz; Pervinder Bhogal; Matthias W Laschke; Michael D Menger; Wolfgang Reith; Philipp Dietrich
Journal:  Clin Neuroradiol       Date:  2020-05-18       Impact factor: 3.649

2.  Endovascular stentectomy using the snare over stent-retriever (SOS) technique: An experimental feasibility study.

Authors:  Tareq Meyer; Omid Nikoubashman; Lisa Kabelitz; Marguerite Müller; Ahmed Othman; Saif Afat; Martin Kramer; Martin Wiesmann; Marc A Brockmann; Carolin Brockmann
Journal:  PLoS One       Date:  2017-05-25       Impact factor: 3.240

3.  Bailout stentectomy of 47 self-expandable intracranial stents.

Authors:  René Chapot; Christian Paul Stracke; Marta Wallocha; Reza Rikhtegar; Elif Yamac; Pascal John Mosimann
Journal:  J Neurointerv Surg       Date:  2021-03-15       Impact factor: 5.836

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.