Literature DB >> 1870485

X-ray imaging using amorphous selenium: a photoinduced discharge readout method for digital mammography.

J A Rowlands1, D M Hunter, N Araj.   

Abstract

A new digital image readout method for electrostatic charge images on photoconductive plates is described. The method can be used to read out images on selenium plates similar to those used in xeromammography. The readout method, called the air-gap photoinduced discharge method (PID), discharges the latent image pixel by pixel and measures the charge. The PID readout method, like electrometer methods, is linear. However, the PID method permits much better resolution than scanning electrometers while maintaining quantum limited performance at high radiation exposure levels. Thus the air-gap PID method appears to be uniquely superior for high-resolution digital imaging tasks such as mammography.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1870485     DOI: 10.1118/1.596689

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

Review 2.  Digital detectors for mammography: the technical challenges.

Authors:  A Noel; F Thibault
Journal:  Eur Radiol       Date:  2004-10-08       Impact factor: 5.315

3.  Reduction of radiation dose for cerebral angiography using flat panel detector of direct conversion type: a vascular phantom study.

Authors:  Y Hatakeyama; S Kakeda; N Ohnari; J Moriya; N Oda; K Nishino; W Miyamoto; Y Korogi
Journal:  AJNR Am J Neuroradiol       Date:  2007-04       Impact factor: 3.825

4.  Comparison of three tissue composition measurement techniques using digital mammograms--a signal-to-noise study.

Authors:  D S Breitenstein; C C Shaw
Journal:  J Digit Imaging       Date:  1998-08       Impact factor: 4.056

Review 5.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

6.  3D digital subtraction angiography of intracranial aneurysms: comparison of flat panel detector with conventional image intensifier TV system using a vascular phantom.

Authors:  S Kakeda; Y Korogi; N Ohnari; Y Hatakeyama; J Moriya; N Oda; K Nishino; W Miyamoto
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

7.  Comparison of acquisition parameters and breast dose in digital mammography and screen-film mammography in the American College of Radiology Imaging Network digital mammographic imaging screening trial.

Authors:  R Edward Hendrick; Etta D Pisano; Alice Averbukh; Catherine Moran; Eric A Berns; Martin J Yaffe; Benjamin Herman; Suddhasatta Acharyya; Constantine Gatsonis
Journal:  AJR Am J Roentgenol       Date:  2010-02       Impact factor: 3.959

8.  Intracranial 2D and 3D DSA with flat panel detector of the direct conversion type: initial experience.

Authors:  Yoshihisa Hatakeyama; Shingo Kakeda; Yukunori Korogi; Norihiro Ohnari; Junji Moriya; Nobuhiro Oda; Kazuyoshi Nishino; Wataru Miyamoto
Journal:  Eur Radiol       Date:  2006-05-18       Impact factor: 7.034

  8 in total