Tibial post wear in posterior-stabilized knee replacements is design-dependent.

Bridgette D Furman1, Joseph Lipman, Mordechai Kligman, Timothy M Wright, Steven B Haas.   

Abstract

Polyethylene tibial post wear in posterior-stabilized knee designs is a major problem. The Insall-Burstein II (IB PS II) reportedly has severe anterior wear of the post in retrieved implants. We hypothesized the more anterior placement in the IB PS II would be reflected in greater wear at the anterior face than the IB PS I. We examined 234 retrieved inserts using subjective scales to grade post damage and wear. Of the IB PS II inserts, 38% demonstrated severe wear compared with only 25% of IB PS I inserts. The most prevalent damage location for the IB PS II was the anterior face, whereas the IB PS I sustained wear mainly on the medial face. While the IB PS post was not designed to constrain posterior femoral displacement, our observations confirm contact in hyperextension or other paradoxic anterior tibial translation is common and design-dependent. Minimizing wear and damage through proper post placement and changes in implant design to anticipate contact on the anterior post should be considered for future posterior stabilized knee replacements. These changes cannot occur in isolation, however, because changes in post placement and design also depend on their relation to the shape and location of the tibial bearing surfaces.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18704615      PMCID: PMC2565057          DOI: 10.1007/s11999-008-0422-1

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  17 in total

1.  Posterior stabilized prosthesis. Results after follow-up of nine to twelve years.

Authors:  S H Stern; J N Insall
Journal:  J Bone Joint Surg Am       Date:  1992-08       Impact factor: 5.284

2.  Anterior tibial post impingement in a posterior stabilized total knee arthroplasty.

Authors:  Guoan Li; Ramprasad Papannagari; Ephrat Most; Sang Eun Park; Todd Johnson; Linggawati Tanamal; Harry E Rubash
Journal:  J Orthop Res       Date:  2005-05       Impact factor: 3.494

3.  Stress analysis of the anterior tibial post in posterior stabilized knee prostheses.

Authors:  Chang-Hung Huang; Jiann-Jong Liau; Chun-Hsiung Huang; Cheng-Kung Cheng
Journal:  J Orthop Res       Date:  2007-04       Impact factor: 3.494

4.  The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system.

Authors:  F C Ewald
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

5.  Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo fluoroscopic analysis during activities of daily living.

Authors:  Silvia Fantozzi; Fabio Catani; Andrea Ensini; Alberto Leardini; Sandro Giannini
Journal:  J Orthop Res       Date:  2006-12       Impact factor: 3.494

6.  Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty.

Authors:  K Nakayama; S Matsuda; H Miura; Y Iwamoto; H Higaki; K Otsuka
Journal:  J Bone Joint Surg Br       Date:  2005-04

7.  Dislocation following primary posterior-stabilized total knee arthroplasty.

Authors:  A V Lombardi; T H Mallory; B K Vaughn; R Krugel; T K Honkala; M Sorscher; M Kolczun
Journal:  J Arthroplasty       Date:  1993-12       Impact factor: 4.757

8.  The posterior stabilized condylar prosthesis: a modification of the total condylar design. Two to four-year clinical experience.

Authors:  J N Insall; P F Lachiewicz; A H Burstein
Journal:  J Bone Joint Surg Am       Date:  1982-12       Impact factor: 5.284

9.  Total knee replacement in young, active patients. Long-term follow-up and functional outcome.

Authors:  D R Diduch; J N Insall; W N Scott; G R Scuderi; D Font-Rodriguez
Journal:  J Bone Joint Surg Am       Date:  1997-04       Impact factor: 5.284

10.  2003 Hap Paul Award Paper of the International Society for Technology in Arthroplasty. Design and activity dependence of kinematics in fixed and mobile-bearing knee arthroplasties.

Authors:  Scott A Banks; W Andrew Hodge
Journal:  J Arthroplasty       Date:  2004-10       Impact factor: 4.757

View more
  10 in total

1.  Surface damage versus tibial polyethylene insert conformity: a retrieval study.

Authors:  Markus A Wimmer; Michel P Laurent; Jeannie D Haman; Joshua J Jacobs; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  The 2012 Mark Coventry award: a retrieval analysis of high flexion versus posterior-stabilized tibial inserts.

Authors:  Nicholas R Paterson; Matthew G Teeter; Steven J MacDonald; Richard W McCalden; Douglas D R Naudie
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

3.  The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

Authors:  Xiaojun Shi; Bin Shen; Pengde Kang; Jing Yang; Zongke Zhou; Fuxing Pei
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-02       Impact factor: 4.342

4.  Implant design influences tibial post wear damage in posterior-stabilized knees.

Authors:  Mark M Dolan; Natalie H Kelly; Joseph T Nguyen; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

5.  How do CAD models compare with reverse engineered manufactured components for use in wear analysis?

Authors:  Matthew G Teeter; Douglas D R Naudie; Robert B Bourne; David W Holdsworth
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

6.  Rotating-platform has no surface damage advantage over fixed-bearing TKA.

Authors:  Kirsten Stoner; Seth A Jerabek; Stephanie Tow; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

7.  Polished trays reduce backside wear independent of post location in posterior-stabilized TKAs.

Authors:  Matthew P Abdel; Mark W Gesell; Christen W Hoedt; Kathleen N Meyers; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2014-04-15       Impact factor: 4.176

Review 8.  How to treat a tibial post fracture in total knee arthroplasty? A systematic review.

Authors:  Paul F Lachiewicz
Journal:  Clin Orthop Relat Res       Date:  2010-10-21       Impact factor: 4.176

9.  Design Modifications of the Posterior-Stabilized Knee System May Reduce Anterior Knee Pain and Complications Following Total Knee Replacement.

Authors:  Jeremy A Dubin; Ahava Muskat; Geoffrey H Westrich
Journal:  HSS J       Date:  2020-01-18

10.  Similar outcomes including maximum knee flexion between mobile bearing condylar-stabilised and fixed bearing posterior-stabilised prosthesis: a case control study.

Authors:  Jobe Shatrov; Elliot Sappey-Marinier; Moussa Kafelov; Stanislas Gunst; Cécile Batailler; Elvire Servien; Sébastien Lustig
Journal:  J Exp Orthop       Date:  2022-02-15
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.