Literature DB >> 18650996

Role of 16-multidetector computed tomography in the assessment of coronary artery stenoses: A prospective study of consecutive patients.

Thomas Postel1, Matthias Frick, Gudrun Feuchtner, Hannes Alber, Ralf Zwick, Alois Suessenbacher, Ammar Mallouhi, Guy Friedrich, Otmar Pachinger, Dieter Zur Nedden, Franz Weidinger.   

Abstract

BACKGROUND: Recent studies have demonstrated a high sensitivity (S) of 16-multidetector computed tomography (16-MDCT) for the detection of significant coronary artery stenoses. Whether these results are applicable to clinical practice is unclear. Therefore, the aim of the present study was to compare 16-MDCT angiography with conventional coronary angiography (CCA) for the detection of significant coronary artery stenoses in a consecutive series of patients.
METHOD: A total of 93 consecutive patients (mean [+/- SD] age 59+/-9 years), in whom CCA was performed for stable angina pectoris, underwent 16-MDCT angiography (16x0.75 mm, table feed 6.5 mm/s, rotation time 0.42 s; Sensation 16, Siemens Medical Solutions, Germany) the day before performing CCA. Patients with diabetes mellitus, serum creatinine level higher than 132.6 mumol/L and/or acute coronary syndromes were excluded. Two observers blinded to CCA results evaluated MDCT angiograms according to standard criteria. Segment-based (13 segments per patient) and patient-based (at least one stenosis greater than 50% lumen diameter reduction) analyses were performed.
RESULTS: A total of 1209 segments were analyzed. Of these segments, 173 (14%) were excluded due to poor image quality or massive calcification. In 86 segments, CCA revealed significant coronary artery stenosis (greater than 50% diameter reduction). However, 16-MDCT detected only 47 of these, resulting in a S of 55% and a specificity (SP) of 97% (positive predictive value 64%; negative predictive value 96%). On a patient-based analysis, the S increased to 89%, whereas the SP still remained high (87%).
CONCLUSION: In this relatively large consecutive cohort, S for the detection of significant coronary artery stenoses was moderate on a segment-based analysis but increased on a patient-based analysis using 16-MDCT. In contrast, SP was high in both analyses, supporting the use of 16-MDCT for the exclusion of significant coronary artery stenoses. Further improvement of spatial and temporal resolution in MDCT technology may lead to a lower exclusion rate and higher S.

Entities:  

Keywords:  16-multidetector computed tomography; Clinical practice; Sensitivity; Specificity; coronary artery disease

Year:  2007        PMID: 18650996      PMCID: PMC2323753     

Source DB:  PubMed          Journal:  Exp Clin Cardiol        ISSN: 1205-6626


  12 in total

1.  Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography.

Authors:  S Achenbach; T Giesler; D Ropers; S Ulzheimer; H Derlien; C Schulte; E Wenkel; W Moshage; W Bautz; W G Daniel; W A Kalender; U Baum
Journal:  Circulation       Date:  2001-05-29       Impact factor: 29.690

2.  Detection of coronary artery stenoses with multislice helical CT angiography.

Authors:  Christoph R Becker; Andreas Knez; Alexander Leber; Hendrik Treede; B Ohnesorge; U Joseph Schoepf; Maximilian F Reiser
Journal:  J Comput Assist Tomogr       Date:  2002 Sep-Oct       Impact factor: 1.826

3.  Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique.

Authors:  David Maintz; Harald Seifarth; Thomas Flohr; Stefan Krämer; Thomas Wichter; Walter Heindel; Roman Fischbach
Journal:  Invest Radiol       Date:  2003-12       Impact factor: 6.016

4.  Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients.

Authors:  A F Kopp; S Schroeder; A Kuettner; A Baumbach; C Georg; R Kuzo; M Heuschmid; B Ohnesorge; K R Karsch; C D Claussen
Journal:  Eur Heart J       Date:  2002-11       Impact factor: 29.983

5.  Noninvasive angiographic evaluation of coronary stents with multi-slice spiral computed tomography.

Authors:  Koen Nieman; Filippo Cademartiri; Rolf Raaijmakers; Peter Pattynama; Pim de Feyter
Journal:  Herz       Date:  2003-03       Impact factor: 1.443

6.  Feasibility of assessment of coronary stent patency using 16-slice computed tomography.

Authors:  Joanne D Schuijf; Jeroen J Bax; J Wouter Jukema; Hildo J Lamb; Hazem M A Warda; Hubert W Vliegen; Albert de Roos; Ernst E van der Wall
Journal:  Am J Cardiol       Date:  2004-08-15       Impact factor: 2.778

7.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

8.  Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris.

Authors:  Nico R Mollet; Filippo Cademartiri; Koen Nieman; Francesco Saia; Pedro A Lemos; Eugene P McFadden; Peter M T Pattynama; Patrick W Serruys; Gabriel P Krestin; Pim J de Feyter
Journal:  J Am Coll Cardiol       Date:  2004-06-16       Impact factor: 24.094

9.  Accuracy of thin-slice computed tomography in the detection of coronary stenoses.

Authors:  Eugenio Martuscelli; Andrea Romagnoli; Alessia D'Eliseo; Cinzia Razzini; Marco Tomassini; Massimiliano Sperandio; Giovanni Simonetti; Francesco Romeo
Journal:  Eur Heart J       Date:  2004-06       Impact factor: 29.983

10.  Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease.

Authors:  Axel Kuettner; Andreas F Kopp; Stephen Schroeder; Thilo Rieger; Juergen Brunn; Christoph Meisner; Martin Heuschmid; Tobias Trabold; Christof Burgstahler; Jens Martensen; Wolfgang Schoebel; Hans-Konrad Selbmann; Claus D Claussen
Journal:  J Am Coll Cardiol       Date:  2004-03-03       Impact factor: 24.094

View more
  3 in total

1.  Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

Authors:  Sabine Schueler; Stefan Walther; Georg M Schuetz; Peter Schlattmann; Marc Dewey
Journal:  Eur Radiol       Date:  2013-01-16       Impact factor: 5.315

Review 2.  Influence of coronary artery disease prevalence on predictive values of coronary CT angiography: a meta-regression analysis.

Authors:  Peter Schlattmann; Georg M Schuetz; Marc Dewey
Journal:  Eur Radiol       Date:  2011-05-20       Impact factor: 5.315

Review 3.  Use of 3x2 tables with an intention to diagnose approach to assess clinical performance of diagnostic tests: meta-analytical evaluation of coronary CT angiography studies.

Authors:  Georg M Schuetz; Peter Schlattmann; Marc Dewey
Journal:  BMJ       Date:  2012-10-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.