Literature DB >> 12398830

Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients.

A F Kopp1, S Schroeder, A Kuettner, A Baumbach, C Georg, R Kuzo, M Heuschmid, B Ohnesorge, K R Karsch, C D Claussen.   

Abstract

AIMS: A new generation of multidetector-row CT (MDCT) scanners allows complete coronary coverage using retrospective ECG gating and 1mm slices. The purpose of this study was to investigate the potential of high resolution MDCT angiography with retrospective gating for detection of coronary artery stenoses. METHODS AND
RESULTS: A total of 102 patients underwent both conventional and MDCT coronary angiography. After intravenous injection of a non-ionic contrast medium the entire heart was scanned within a single breath hold using 1mm slices. All MDCT data sets were reconstructed with retrospective gating at 20% to 80% in increments of 10% relative to the cardiac cycle. Two blinded independent reviewers analysed image quality for segments 1-4 (right coronary artery), 5-8 (left main, left anterior descending), and 11, 12 (left circumflex). These segments were evaluated for the presence or absence of significant (>or=50%) stenoses. The results were compared with those of invasive coronary angiography in a blinded fashion. Overall sensitivity for the detection of significant stenoses (>or=50%) were 0.86 (reader 1) and 0.93 (reader 2), specificity 0.96 (reader 1) and 0.97 (reader 2), negative predictive value 0.98 (reader 1) and 0.99 (reader 2).
CONCLUSIONS: High resolution MDCT angiography with retrospective gating permits the non-invasive detection of coronary artery stenoses with high accuracy if image quality is optimized for each of the three major coronary arteries. Copyright 2002 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2002        PMID: 12398830     DOI: 10.1053/euhj.2002.3264

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  36 in total

1.  Multislice CT angiography in coronary artery disease: Technical developments, radiation dose and diagnostic value.

Authors:  Zhonghua Sun
Journal:  World J Cardiol       Date:  2010-10-26

2.  Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time.

Authors:  Xavier L Hamoir; Thomas Flohr; Vincent Hamoir; Laurent Labaki; Jean-Yves Tricquet; Alain Duhamel; Jacques Kirsch
Journal:  Eur Radiol       Date:  2004-11-24       Impact factor: 5.315

3.  Non-invasive coronary angiography using multislice computed tomography.

Authors:  Jeffrey M Schussler; Paul A Grayburn
Journal:  Heart       Date:  2005-12-30       Impact factor: 5.994

4.  Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience.

Authors:  Martin H K Hoffmann; Jonathan Lessick; Robert Manzke; Florian T Schmid; Edward Gershin; Daniel T Boll; Shmuel Rispler; Andrik J Aschoff; Michael Grass
Journal:  Eur Radiol       Date:  2005-07-14       Impact factor: 5.315

5.  Assessment of left ventricular wall motion using 16-channel multislice computed tomography: comparison with left ventriculography.

Authors:  Toyoaki Haraikawa; Hiroshi Higashino; Yoshifumi Sugawara; Hitoshi Miki; Akira Kurata; Jitsuo Higaki; Teruhito Mochizuki
Journal:  Radiat Med       Date:  2006-04

6.  Mutidetector-row CT and quantitative gated SPECT for the assessment of left ventricular function in small hearts: the cardiac physical phantom study using a combined SPECT/CT system.

Authors:  Daisuke Utsunomiya; Seiji Tomiguchi; Kazuo Awai; Shinya Shiraishi; Takeshi Nakaura; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2006-02-03       Impact factor: 5.315

Review 7.  Cardiac CT: coronary arteries and beyond.

Authors:  Andreas H Mahnken; Georg Mühlenbruch; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-10-26       Impact factor: 5.315

Review 8.  Comprehensive cardiac CT study: evaluation of coronary arteries, left ventricular function, and myocardial perfusion--is it possible?

Authors:  Ricardo C Cury; Koen Nieman; Michael D Shapiro; Khurram Nasir; Roberto C Cury; Thomas J Brady
Journal:  J Nucl Cardiol       Date:  2007-04       Impact factor: 5.952

Review 9.  Coronary CT angiography: Diagnostic value and clinical challenges.

Authors:  Akmal Sabarudin; Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

10.  Highly accurate coronary angiography with submillimetre, 16 slice computed tomography.

Authors:  G J Morgan-Hughes; C A Roobottom; P E Owens; A J Marshall
Journal:  Heart       Date:  2005-03       Impact factor: 5.994

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.