Literature DB >> 18601464

Constrained tibial vibration in mice: a method for studying the effects of vibrational loading of bone.

Blaine A Christiansen1, Philip V Bayly, Matthew J Silva.   

Abstract

Vibrational loading can stimulate the formation of new trabecular bone or maintain bone mass. Studies investigating vibrational loading have often used whole-body vibration (WBV) as their loading method. However, WBV has limitations in small animal studies because transmissibility of vibration is dependent on posture. In this study, we propose constrained tibial vibration (CTV) as an experimental method for vibrational loading of mice under controlled conditions. In CTV, the lower leg of an anesthetized mouse is subjected to vertical vibrational loading while supporting a mass. The setup approximates a one degree-of-freedom vibrational system. Accelerometers were used to measure transmissibility of vibration through the lower leg in CTV at frequencies from 20 Hz to 150 Hz. First, the frequency response of transmissibility was quantified in vivo, and dissections were performed to remove one component of the mouse leg (the knee joint, foot, or soft tissue) to investigate the contribution of each component to the frequency response of the intact leg. Next, a finite element (FE) model of a mouse tibia-fibula was used to estimate the deformation of the bone during CTV. Finally, strain gages were used to determine the dependence of bone strain on loading frequency. The in vivo mouse leg in the CTV system had a resonant frequency of 60 Hz for +/-0.5 G vibration (1.0 G peak to peak). Removing the foot caused the natural frequency of the system to shift from 60 Hz to 70 Hz, removing the soft tissue caused no change in natural frequency, and removing the knee changed the natural frequency from 60 Hz to 90 Hz. By using the FE model, maximum tensile and compressive strains during CTV were estimated to be on the cranial-medial and caudolateral surfaces of the tibia, respectively, and the peak transmissibility and peak cortical strain occurred at the same frequency. Strain gage data confirmed the relationship between peak transmissibility and peak bone strain indicated by the FE model, and showed that the maximum cyclic tibial strain during CTV of the intact leg was 330+/-82microepsilon and occurred at 60-70 Hz. This study presents a comprehensive mechanical analysis of CTV, a loading method for studying vibrational loading under controlled conditions. This model will be used in future in vivo studies and will potentially become an important tool for understanding the response of bone to vibrational loading.

Entities:  

Mesh:

Year:  2008        PMID: 18601464      PMCID: PMC2893880          DOI: 10.1115/1.2917435

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  15 in total

1.  Mechanical strain, induced noninvasively in the high-frequency domain, is anabolic to cancellous bone, but not cortical bone.

Authors:  C Rubin; A S Turner; C Mallinckrodt; C Jerome; K McLeod; S Bain
Journal:  Bone       Date:  2002-03       Impact factor: 4.398

2.  Anabolism. Low mechanical signals strengthen long bones.

Authors:  C Rubin; A S Turner; S Bain; C Mallinckrodt; K McLeod
Journal:  Nature       Date:  2001-08-09       Impact factor: 49.962

3.  Low magnitude mechanical loading is osteogenic in children with disabling conditions.

Authors:  Kate Ward; Chrissie Alsop; Janette Caulton; Clinton Rubin; Judith Adams; Zulf Mughal
Journal:  J Bone Miner Res       Date:  2004-01-27       Impact factor: 6.741

4.  Age-related bone loss. A hypothesis and initial assessment in mice.

Authors:  A Kahn; R Gibbons; S Perkins; D Gazit
Journal:  Clin Orthop Relat Res       Date:  1995-04       Impact factor: 4.176

5.  Low-level accelerations applied in the absence of weight bearing can enhance trabecular bone formation.

Authors:  Russell Garman; Glenn Gaudette; Leah-Rae Donahue; Clinton Rubin; Stefan Judex
Journal:  J Orthop Res       Date:  2007-06       Impact factor: 3.494

6.  Nanoindentation and whole-bone bending estimates of material properties in bones from the senescence accelerated mouse SAMP6.

Authors:  Matthew J Silva; Michael D Brodt; Zaifeng Fan; Jae-Young Rho
Journal:  J Biomech       Date:  2004-11       Impact factor: 2.712

7.  Rest insertion combined with high-frequency loading enhances osteogenesis.

Authors:  Jeremy M LaMothe; Ronald F Zernicke
Journal:  J Appl Physiol (1985)       Date:  2004-01-05

8.  Genetic predisposition to low bone mass is paralleled by an enhanced sensitivity to signals anabolic to the skeleton.

Authors:  Stefan Judex; Leah-Rae Donahue; Clinton Rubin
Journal:  FASEB J       Date:  2002-06-21       Impact factor: 5.191

9.  Effect of 6-month whole body vibration training on hip density, muscle strength, and postural control in postmenopausal women: a randomized controlled pilot study.

Authors:  Sabine M P Verschueren; Machteld Roelants; Christophe Delecluse; Stephan Swinnen; Dirk Vanderschueren; Steven Boonen
Journal:  J Bone Miner Res       Date:  2003-12-22       Impact factor: 6.741

10.  Prevention of postmenopausal bone loss by a low-magnitude, high-frequency mechanical stimuli: a clinical trial assessing compliance, efficacy, and safety.

Authors:  Clinton Rubin; Robert Recker; Diane Cullen; John Ryaby; Joan McCabe; Kenneth McLeod
Journal:  J Bone Miner Res       Date:  2003-12-22       Impact factor: 6.741

View more
  13 in total

1.  Comparative vibration levels perceived among species in a laboratory animal facility.

Authors:  John N Norton; Will L Kinard; Randall P Reynolds
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-09       Impact factor: 1.232

2.  Mechanical loading, damping, and load-driven bone formation in mouse tibiae.

Authors:  Todd Dodge; Mina Wanis; Ramez Ayoub; Liming Zhao; Nelson B Watts; Amit Bhattacharya; Ozan Akkus; Alexander Robling; Hiroki Yokota
Journal:  Bone       Date:  2012-07-31       Impact factor: 4.398

3.  Gravitational force modulates muscle activity during mechanical oscillation of the tibia in humans.

Authors:  Shuo-Hsiu Chang; Shauna Dudley-Javoroski; Richard K Shields
Journal:  J Electromyogr Kinesiol       Date:  2011-06-25       Impact factor: 2.368

4.  In vivo axial loading of the mouse tibia.

Authors:  Katherine M Melville; Alexander G Robling; Marjolein C H van der Meulen
Journal:  Methods Mol Biol       Date:  2015

5.  Short-term low-strain vibration enhances chemo-transport yet does not stimulate osteogenic gene expression or cortical bone formation in adult mice.

Authors:  Akhilesh A Kotiya; Philip V Bayly; Matthew J Silva
Journal:  Bone       Date:  2010-10-16       Impact factor: 4.398

6.  Constrained tibial vibration does not produce an anabolic bone response in adult mice.

Authors:  Blaine A Christiansen; Akhilesh A Kotiya; Matthew J Silva
Journal:  Bone       Date:  2009-07-01       Impact factor: 4.398

7.  Experimental and finite element analysis of strains induced by axial tibial compression in young-adult and old female C57Bl/6 mice.

Authors:  Tarpit K Patel; Michael D Brodt; Matthew J Silva
Journal:  J Biomech       Date:  2013-11-13       Impact factor: 2.712

8.  Resonance in the mouse tibia as a predictor of frequencies and locations of loading-induced bone formation.

Authors:  Liming Zhao; Todd Dodge; Arun Nemani; Hiroki Yokota
Journal:  Biomech Model Mechanobiol       Date:  2013-04-11

9.  Aging diminishes lamellar and woven bone formation induced by tibial compression in adult C57BL/6.

Authors:  Nilsson Holguin; Michael D Brodt; Michelle E Sanchez; Matthew J Silva
Journal:  Bone       Date:  2014-05-15       Impact factor: 4.398

10.  Estimation of load conditions and strain distribution for in vivo murine tibia compression loading using experimentally informed finite element models.

Authors:  Edmund Pickering; Matthew J Silva; Peter Delisser; Michael D Brodt; YuanTong Gu; Peter Pivonka
Journal:  J Biomech       Date:  2020-12-13       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.