Literature DB >> 18581361

Spatiotemporal magnetic field monitoring for MR.

Christoph Barmet1, Nicola De Zanche, Klaas P Pruessmann.   

Abstract

MR experiments frequently rely on signal encoding by the application of magnetic fields that vary in both space and time. The accurate interpretation of the resulting signals often requires knowledge of the exact spatiotemporal field evolution during the experiment. To better fulfill this need, a new approach is presented that enables measuring the field evolution concurrently with any MR sequence. Miniature NMR probes are used to monitor the MR phase evolution around the object under investigation. Based on these data, a global phase model is calculated that can then be used as a basis for processing the actual image or spectroscopic data. The new method is demonstrated by MRI of a phantom, using spin-warp, spiral, and EPI trajectories. Throughout, the monitoring results enabled highly accurate image reconstruction, even in the presence of massive gradient imperfections. (c) 2008 Wiley-Liss, Inc.

Mesh:

Year:  2008        PMID: 18581361     DOI: 10.1002/mrm.21603

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  41 in total

1.  Trajectory Auto-Corrected image reconstruction.

Authors:  Julianna D Ianni; William A Grissom
Journal:  Magn Reson Med       Date:  2015-09-12       Impact factor: 4.668

2.  Correction of B 0-induced geometric distortion variations in prospective motion correction for 7T MRI.

Authors:  Uten Yarach; Chaiya Luengviriya; Daniel Stucht; Frank Godenschweger; Peter Schulze; Oliver Speck
Journal:  MAGMA       Date:  2016-02-09       Impact factor: 2.310

3.  Inductive measurement and encoding of k-space trajectories in MR raw data.

Authors:  Jan Ole Pedersen; Christian G Hanson; Rong Xue; Lars G Hanson
Journal:  MAGMA       Date:  2019-07-30       Impact factor: 2.310

4.  A multifunction digital receiver suitable for real-time frequency detection and compensation in fast magnetic resonance imaging.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  Rev Sci Instrum       Date:  2019-05       Impact factor: 1.523

5.  Correction of parallel transmission using concurrent RF and gradient field monitoring.

Authors:  Mustafa Çavuşoğlu; Benjamin Emanuel Dietrich; David Otto Brunner; Markus Weiger; Klaas Paul Pruessmann
Journal:  MAGMA       Date:  2017-04-25       Impact factor: 2.310

6.  Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication.

Authors:  Dean Darnell; Jonathan Cuthbertson; Fraser Robb; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2018-09-14       Impact factor: 4.668

7.  Parallel 2D FFT implementation on FPGA suitable for real-time MR image processing.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  Rev Sci Instrum       Date:  2018-09       Impact factor: 1.523

8.  A robust coregistration method for in vivo studies using a first generation simultaneous PET/MR scanner.

Authors:  Thomas S C Ng; Daniel Procissi; Yibao Wu; Russell E Jacobs
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

9.  Ramped hybrid encoding for improved ultrashort echo time imaging.

Authors:  Hyungseok Jang; Curtis N Wiens; Alan B McMillan
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

10.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.