Literature DB >> 30278692

Parallel 2D FFT implementation on FPGA suitable for real-time MR image processing.

Limin Li1, Alice M Wyrwicz1.   

Abstract

We report the design and implementation of a parallel two-dimensional fast Fourier transform (2D FFT) algorithm on a Field Programmable Gate Array (FPGA) for real-time MR image processing. Although a number of architectures of 2D FFT hardware processors have been reported, these generic processors or IP cores are not always effective for processing MRI data. The key feature of our design is that our processors are customized solely for real-time MRI applications. We demonstrate that by considering the unique features of real-time MRI data streams, we were able to develop and implement the 2D FFT processors that are resource-efficient and flexible enough to handle both regular and irregular data. Using a data-driven approach, we were able to simplify the inter-processor data communication while maintaining data synchronization without a synchronous clock signal bus and complex interconnection network. We experimentally verified our designs by processing multi-slice image data sets with 128 × 128 and 256 × 256 in-plane resolution. The results demonstrate the effectiveness of our 2D FFT processors and show that image reconstruction can be accelerated in proportion to the parallel processing factor. We achieved image-reconstruction processing rates up to 3000 and 800 slices per second for images with 128 × 128 and 256 × 256 in-plane resolution, respectively. The results also indicate that the image-reconstruction acceleration is primarily limited by the speed of the data transfer between the FPGA device and external sensors.

Year:  2018        PMID: 30278692      PMCID: PMC6150773          DOI: 10.1063/1.5019846

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  13 in total

1.  Investigation of acoustic noise on 15 MRI scanners from 0.2 T to 3 T.

Authors:  D L Price; J P De Wilde; A M Papadaki; J S Curran; R I Kitney
Journal:  J Magn Reson Imaging       Date:  2001-02       Impact factor: 4.813

2.  Design of an MR image processing module on an FPGA chip.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  J Magn Reson       Date:  2015-03-23       Impact factor: 2.229

3.  Spatiotemporal magnetic field monitoring for MR.

Authors:  Christoph Barmet; Nicola De Zanche; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

4.  Addressing a systematic vibration artifact in diffusion-weighted MRI.

Authors:  Daniel Gallichan; Jan Scholz; Andreas Bartsch; Timothy E Behrens; Matthew D Robson; Karla L Miller
Journal:  Hum Brain Mapp       Date:  2010-02       Impact factor: 5.038

Review 5.  GPU computing in medical physics: a review.

Authors:  Guillem Pratx; Lei Xing
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

6.  Real-time feedback for spatiotemporal field stabilization in MR systems.

Authors:  Yolanda Duerst; Bertram J Wilm; Benjamin E Dietrich; S Johanna Vannesjo; Christoph Barmet; Thomas Schmid; David O Brunner; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2014-03-13       Impact factor: 4.668

7.  Modularized architecture of address generation units suitable for real-time processing MR data on an FPGA.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  Rev Sci Instrum       Date:  2016-06       Impact factor: 1.523

8.  Reduction of pulsed gradient settling time in the superconducting magnet of a magnetic resonance instrument.

Authors:  D J Jensen; W W Brey; J L Delayre; P A Narayana
Journal:  Med Phys       Date:  1987 Sep-Oct       Impact factor: 4.071

9.  RARE imaging: a fast imaging method for clinical MR.

Authors:  J Hennig; A Nauerth; H Friedburg
Journal:  Magn Reson Med       Date:  1986-12       Impact factor: 4.668

10.  Spin warp NMR imaging and applications to human whole-body imaging.

Authors:  W A Edelstein; J M Hutchison; G Johnson; T Redpath
Journal:  Phys Med Biol       Date:  1980-07       Impact factor: 3.609

View more
  1 in total

1.  A multifunction digital receiver suitable for real-time frequency detection and compensation in fast magnetic resonance imaging.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  Rev Sci Instrum       Date:  2019-05       Impact factor: 1.523

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.