Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mTc/ 123I SPECT imaging.

Jinsong Ouyang1, Georges El Fakhri, Stephen C Moore.   

Abstract

Simultaneous 99mTC/ 123I SPECT allows the assessment of two physiological functions under identical conditions. The separation of these radionuclides is difficult, however, because their energies are close. Most energy-window-based scatter correction methods do not fully model either physical factors or patient-specific activity and attenuation distributions. We have developed a fast Monte Carlo (MC) simulation-based multiple-radionuclide and multiple-energy joint ordered-subset expectation-maximization (JOSEM) iterative reconstruction algorithm, MC-JOSEM. MC-JOSEM simultaneously corrects for scatter and cross talk as well as detector response within the reconstruction algorithm. We evaluated MC-JOSEM for simultaneous brain profusion (99mTc-HMPAO) and neurotransmission (123I-altropane) SPECT. MC simulations of 99mTc and 123I studies were generated separately and then combined to mimic simultaneous 99mTc/ 123I SPECT. All the details of photon transport through the brain, the collimator, and detector, including Compton and coherent scatter, septal penetration, and backscatter from components behind the crystal, were modeled. We reconstructed images from simultaneous dual-radionuclide projections in three ways. First, we reconstructed the photopeak-energy-window projections (with an asymmetric energy window for 1231) using the standard ordered-subsets expectation-maximization algorithm (NSC-OSEM). Second, we used standard OSEM to reconstruct 99mTc photopeak-energy-window projections, while including an estimate of scatter from a Compton-scatter energy window (SC-OSEM). Third, we jointly reconstructed both 99mTc and 123I images using projection data associated with two photo-peak energy windows and an intermediate-energy window using MC-JOSEM. For 15 iterations of reconstruction, the bias and standard deviation of 99mTc activity estimates in several brain structures were calculated for NSC-OSEM, SC-OSEM, and MC-JOSEM, using images reconstructed from primary (unscattered) photons as a reference. Similar calculations were performed for 123I images for NSC-OSEM and MC-JOSEM. For 123I images, dopamine binding potential (BP) at equilibrium and its signal-to-noise ratio (SNR) were also calculated. Our results demonstrate that MC-JOSEM performs better than NSC- and SC-OSEM for quantitation tasks. After 15 iterations of reconstruction, the relative bias of 99mTc activity estimates in the thalamus, striata, white matter, and gray matter volumes from MC-JOSEM ranged from -2.4% to 1.2%, while the same estimates for NSC-OSEM (SC-OSEM) ranged from 20.8% to 103.6% (7.2% to 41.9%). Similarly, the relative bias of 123I activity estimates from 15 iterations of MC-JOSEM in the striata and background ranged from -1.4% to 2.9%, while the same estimates for NSC-OSEM ranged from 1.6% to 10.0%. The relative standard deviation of 99mTc activity estimates from MC-JOSEM ranged from 1.1% to 4.8% versus 1.2% to 6.7% (1.2% to 5.9%) for NSC-OSEM (SC-OSEM). The relative standard deviation of 123I activity estimates using MC-JOSEM ranged from 1.1% to 1.9% versus 1.5% to 2.7% for NSC-OSEM. Using the 123I dopamine BP obtained from the reconstruction produced by primary photons as a reference, the result for MC-JOSEM was 50.5% closer to the reference than that of NSC-OSEM after 15 iterations. The SNR for dopamine BP was 23.6 for MC-JOSEM as compared to 18.3 for NSC-OSEM.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17879789     DOI: 10.1118/1.2756601

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Navigating beyond the 6th dimension: a challenge in the era of multi-parametric molecular imaging.

Authors:  Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-07       Impact factor: 9.236

2.  Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

Authors:  C M Trott; J Ouyang; G El Fakhri
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

3.  Joint reconstruction of Ictal/inter-ictal SPECT data for improved epileptic foci localization.

Authors:  Yothin Rakvongthai; Frederic Fahey; Korn Borvorntanajanya; Supatporn Tepmongkol; Usanee Vutrapongwatana; Katherine Zukotynski; Georges El Fakhri; Jinsong Ouyang
Journal:  Med Phys       Date:  2017-04       Impact factor: 4.071

4.  Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc/123I dual-isotope simultaneous acquisition brain SPECT.

Authors:  Yong Du; Eric C Frey
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

5.  Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Authors:  Yong Du; Manojeet Bhattacharya; Eric C Frey
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

6.  Quantitative simultaneous 99mTc/123I cardiac SPECT using MC-JOSEM.

Authors:  Jinsong Ouyang; Xuping Zhu; Cathryn M Trott; Georges El Fakhri
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

7.  Improved activity estimation with MC-JOSEM versus TEW-JOSEM in 111In SPECT.

Authors:  Jinsong Ouyang; Georges El Fakhri; Stephen C Moore
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

8.  Sequential and simultaneous dual-isotope brain SPECT: comparison with PET for estimation and discrimination tasks in early Parkinson disease.

Authors:  Cathryn M Trott; Georges El Fakhri
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

9.  Is absolute quantification of dopaminergic neurotransmission studies with 123I SPECT ready for clinical use?

Authors:  Habib Zaidi; Georges El Fakhri
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-07       Impact factor: 9.236

10.  Quantitative simultaneous 111In∕99mTc SPECT-CT of osteomyelitis.

Authors:  Morgan Cervo; Victor H Gerbaudo; Mi-Ae Park; Stephen C Moore
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.