LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 20-250 kVp relative to 60Co.

A A Nunn1, S D Davis, J A Micka, L A DeWerd.   

Abstract

The response of LiF:Mg,Ti thermoluminescent dosimeters (TLDs) as a function of photon energy was determined using irradiations with moderately filtered x-ray beams in the energy range of 20-250 kVp relative to the response to irradiations with 60Co photons. To determine if the relative light output from LiF:Mg,Ti TLDs per unit air kerma as a function of photon energy can be predicted using calculations such as Monte Carlo (MC) simulations, measurements from the x-ray beam irradiations were compared with MC calculated results, similar to the methodology used by Davis et al. [Radiat. Prot. Dosim. 106, 33-43 (2003)]. TLDs were irradiated in photon beams with well-known air kerma rates using the National Institute of Standards and Technology traceable M-series x-ray beams in the range of 20-250 kVp. For each x-ray beam, several sets of TLDs were irradiated for times corresponding to different air kerma levels to take into account any dose nonlinearity. TLD light output was then compared to that from several sets of TLDs irradiated at similar corresponding air kerma levels using a 60Co irradiator. The MC code MCNP5 was used to account for photon scatter and attenuation in the holder and TLDs and was used to calculate the predicted relative TLD light output per unit air kerma for irradiations with each of the experimentally used photon beams. The measured relative TLD response as a function of photon energy differed by up to 13% from the MC calculations. We conclude that MC calculations do not accurately predict the relative response of TLDs as a function of photon energy, consistent with the conclusions of Davis et al. [Radiat. Prot. Dosim. 106, 33-43 (2003)]. This is likely due to complications in the solid state physics of the thermoluminescence process that are not incorporated into the simulation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18561661     DOI: 10.1118/1.2898137

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Dosimetric characterization of a new directional low-dose rate brachytherapy source.

Authors:  Manik Aima; Larry A DeWerd; Michael G Mitch; Clifford G Hammer; Wesley S Culberson
Journal:  Med Phys       Date:  2018-05-24       Impact factor: 4.071

2.  Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner.

Authors:  Bradley P McCabe; Michael A Speidel; Tina L Pike; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

3.  Variations in photon energy spectra of a 6 MV beam and their impact on TLD response.

Authors:  Sarah B Scarboro; David S Followill; Rebecca M Howell; Stephen F Kry
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

4.  TLD measurements and Monte Carlo calculations of head and neck organ and effective doses for cone beam computed tomography using 3D Accuitomo 170.

Authors:  Marina Ernst; Peter Manser; Karl Dula; Werner Volken; Marco Fm Stampanoni; Michael K Fix
Journal:  Dentomaxillofac Radiol       Date:  2017-07-27       Impact factor: 2.419

5.  Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

Authors:  Regina K Fulkerson; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

6.  Effect of anode angle on photon beam spectra and depth dose characteristics for X-RAD320 orthovoltage unit.

Authors:  Asghar Mesbahi; Seyed-Salman Zakariaee
Journal:  Rep Pract Oncol Radiother       Date:  2013-01-16

7.  A real-time Monte Carlo tool for individualized dose estimations in clinical CT.

Authors:  Shobhit Sharma; Anuj Kapadia; Wanyi Fu; Ehsan Abadi; W Paul Segars; Ehsan Samei
Journal:  Phys Med Biol       Date:  2019-11-04       Impact factor: 3.609

8.  Organ doses from CT localizer radiographs: Development, validation, and application of a Monte Carlo estimation technique.

Authors:  Jocelyn Hoye; Shobhit Sharma; Yakun Zhang; Wanyi Fu; Francesco Ria; Anuj Kapadia; W Paul Segars; Joshua Wilson; Ehsan Samei
Journal:  Med Phys       Date:  2019-09-16       Impact factor: 4.071

9.  Determination of exit skin dose for 192Ir intracavitary accelerated partial breast irradiation with thermoluminescent dosimeters.

Authors:  Julie A Raffi; Stephen D Davis; Cliff G Hammer; John A Micka; Keith A Kunugi; Jana E Musgrove; John W Winston; Terresa J Ricci-Ott; Larry A DeWerd
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

10.  A concern on in-phantom photon energy response of luminescence dosimeters for clinical applications.

Authors:  A S Pradhan
Journal:  J Med Phys       Date:  2010-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.