Highly crosslinked vs conventional polyethylene particles--an in vitro comparison of biologic activities.

Richard Lynn Illgen1, Todd M Forsythe, J Wesley Pike, Michel P Laurent, Cheryl R Blanchard.   

Abstract

Highly cross-linked polyethylenes (HXPEs) have been introduced to reduce wear after hip arthroplasty. The improved wear characteristics of HXPEs are well documented, but the relative biologic activity of HXPE and conventional polyethylene (CPE) particles remains unclear. Longevity (Zimmer, Warsaw, Ind; HXPE) and GUR 1050 (Zimmer; CPE) particles were isolated and characterized from a hip simulator and their in vitro inflammatory responses (tissue necrosis factor *, interleukin 1*, and vascular endothelial growth factor levels) were compared using macrophages. The average diameter of Longevity particles (0.111 microm) was smaller than CPE particles (0.196 microm), and both were predominantly round (granular appearance). The inflammatory response to HXPE and CPE was concentration-dependent. No statistically significant differences were noted at low (0.1 surface area ratio [SAR]) and intermediate (0.75 SAR) doses. At the highest dose tested (2.5 SAR), HXPE was significantly more inflammatory than CPE based on relative tissue necrosis factor alpha and vascular endothelial growth factor secretion levels. Further study is needed to determine if similar findings would be noted in vivo over a broad concentration range.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18534392     DOI: 10.1016/j.arth.2007.05.043

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  19 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Comparison of the cytotoxic and inflammatory responses of titanium particles with different methods for endotoxin removal in RAW264.7 macrophages.

Authors:  Huifeng Ding; Zhenan Zhu; Tingting Tang; Degang Yu; Bo Yu; Kerong Dai
Journal:  J Mater Sci Mater Med       Date:  2012-02-23       Impact factor: 3.896

3.  CORR Insights(®): oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  Alexander Jaime Grübl
Journal:  Clin Orthop Relat Res       Date:  2015-09-10       Impact factor: 4.176

Review 4.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

5.  Characteristics of highly cross-linked polyethylene wear debris in vivo.

Authors:  Ryan M Baxter; Daniel W MacDonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-02-22       Impact factor: 3.368

6.  Biological activity and migration of wear particles in the knee joint: an in vivo comparison of six different polyethylene materials.

Authors:  S Utzschneider; V Lorber; M Dedic; A C Paulus; C Schröder; O Gottschalk; M Schmitt-Sody; V Jansson
Journal:  J Mater Sci Mater Med       Date:  2014-02-22       Impact factor: 3.896

7.  [Principles of tribological analysis of endoprostheses].

Authors:  J P Kretzer; C Zietz; C Schröder; J Reinders; L Middelborg; A Paulus; R Sonntag; R Bader; S Utzschneider
Journal:  Orthopade       Date:  2012-10       Impact factor: 1.087

8.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

9.  Role of polyethylene particles in peri-prosthetic osteolysis: A review.

Authors:  Gerald J Atkins; David R Haynes; Donald W Howie; David M Findlay
Journal:  World J Orthop       Date:  2011-10-18

10.  Wear testing of a canine hip resurfacing implant that uses highly cross-linked polyethylene.

Authors:  Kevin J Warburton; John B Everingham; Jillian L Helms; Andrew J Kazanovicz; Katherine A Hollar; Jeff D Brourman; Steven M Fox; Trevor J Lujan
Journal:  J Orthop Res       Date:  2017-11-14       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.