Literature DB >> 18478202

Cutting errors in total knee replacement: assessment by computer assisted surgery.

W P Yau1, K Y Chiu.   

Abstract

The observed errors in the position of the implanted prosthesis can be due to a number of potential causes. One of these is the potential error during execution of the bone cuts. However, there is only minimal information on this in the current literature. The amount of cutting errors in 40 consecutive total knee replacements was reported. All the operations were done by the same surgeon. The amount of cutting error was measured by the use of computer navigation system. It was hypothesized that there was no difference in the amount of error between bone cut through the cutting slot (slotted cutting) and bone cut done on the surface of the cutting guide (open cutting). It was found that the average absolute cutting error was 1 masculine in the coronal plane and 1.4 masculine in the sagittal plane. Significantly more outlier (more than 3 masculine) was observed in the errors in the sagittal plane (P = 0.014, chi square test). Open cutting resulted in less error in the sagittal plane of the tibial cut when compared with slotted cutting (P = 0.031, Mann-Whitney U Test). This was attributed by the use of a thicker saw blade with higher stiffness in the open cutting method.

Mesh:

Year:  2008        PMID: 18478202     DOI: 10.1007/s00167-008-0550-x

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  14 in total

1.  Radiologic analysis of the tibial intramedullary canal in Chinese varus knees: implications in total knee arthroplasty.

Authors:  P S Ko; M K Tio; C M Ban; Y K Mak; F K Ip; J J Lam
Journal:  J Arthroplasty       Date:  2001-02       Impact factor: 4.757

2.  Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients.

Authors:  S David Stulberg; Peter Loan; Vineet Sarin
Journal:  J Bone Joint Surg Am       Date:  2002       Impact factor: 5.284

3.  Accuracy of intramedullary alignment in total knee replacement.

Authors:  M A Elloy; M P Manning; R Johnson
Journal:  J Biomed Eng       Date:  1992-09

4.  Bone cutting errors in total knee arthroplasty.

Authors:  Christopher Plaskos; Antony J Hodgson; Kevin Inkpen; Robert W McGraw
Journal:  J Arthroplasty       Date:  2002-09       Impact factor: 4.757

5.  Intraoperative cutting errors in total knee arthroplasty.

Authors:  H Bäthis; L Perlick; M Tingart; C Perlick; C Lüring; J Grifka
Journal:  Arch Orthop Trauma Surg       Date:  2004-11-09       Impact factor: 3.067

6.  Coronal alignment after total knee replacement.

Authors:  R S Jeffery; R W Morris; R A Denham
Journal:  J Bone Joint Surg Br       Date:  1991-09

7.  Tibial intramedullary alignment in total knee arthroplasty.

Authors:  J V Bono; D J Roger; R S Laskin; M G Peterson; C A Paulsen
Journal:  Am J Knee Surg       Date:  1995

8.  Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position: a radiographic analysis.

Authors:  A Maestro; S F Harwin; M G Sandoval; D H Vaquero; A Murcia
Journal:  J Arthroplasty       Date:  1998-08       Impact factor: 4.757

9.  Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty.

Authors:  S H Yang; T K Liu
Journal:  J Formos Med Assoc       Date:  1998-08       Impact factor: 3.282

10.  Ten-year evaluation of geometric total knee arthroplasty.

Authors:  J A Rand; M B Coventry
Journal:  Clin Orthop Relat Res       Date:  1988-07       Impact factor: 4.176

View more
  14 in total

1.  No difference between tibia-first and femur-first techniques in TKA using computer-assisted surgery.

Authors:  Roland Becker; Markus Malzdorf; Christian Stärke; Pirtkien Randolf; Christoph Lohmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-02-25       Impact factor: 4.342

2.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

3.  Do manual cutting guides for total knee arthroplasty introduce systematic error?

Authors:  Erik Hohmann; Kevin Tetsworth
Journal:  Int Orthop       Date:  2015-08-23       Impact factor: 3.075

4.  Alignment in total knee arthroplasty, still more questions than answers….

Authors:  Emmanuel Thienpont; Johan Bellemans; Jan Victor; Roland Becker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10       Impact factor: 4.342

5.  Navigated total knee arthroplasty: is it error-free?

Authors:  Kerk Hsiang Zackary Chua; Yongsheng Chen; Krishna Lingaraj
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-06       Impact factor: 4.342

6.  Case-related factors affecting cutting errors of the proximal tibia in total knee arthroplasty assessed by computer navigation.

Authors:  Tadashi Tsukeoka; Yoshikazu Tsuneizumi; Kensuke Yoshino; Mashiko Suzuki
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-12-22       Impact factor: 4.342

7.  Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system.

Authors:  Masahiro Hasegawa; Kakunoshin Yoshida; Hiroki Wakabayashi; Akihiro Sudo
Journal:  Int Orthop       Date:  2012-10-28       Impact factor: 3.075

8.  A modified technique to reduce tibial keel cutting errors during an Oxford unicompartmental knee arthroplasty.

Authors:  Hiroshi Inui; Shuji Taketomi; Keitarou Tahara; Ryota Yamagami; Takaki Sanada; Sakae Tanaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-02       Impact factor: 4.342

9.  Conventional instruments are more accurate for measuring the depth of the tibial cut than computer-assisted surgery in total knee arthroplasty: a prospective study.

Authors:  Antonio Klasan; Sven Edward Putnis; Samuel Grasso; Thomas Neri; Myles Raphael Coolican
Journal:  Arch Orthop Trauma Surg       Date:  2020-03-07       Impact factor: 3.067

10.  Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement.

Authors:  Vikas Karade; B Ravi; Manish Agarwal
Journal:  J Orthop Surg Res       Date:  2012-10-02       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.