Literature DB >> 7866803

Tibial intramedullary alignment in total knee arthroplasty.

J V Bono1, D J Roger, R S Laskin, M G Peterson, C A Paulsen.   

Abstract

This article describes a study that assessed the accuracy of a tibial intramedullary alignment device in 44 adult cadaveric tibiae. The results suggest that greater accuracy is achieved if the device is inserted fully to the level of the distal epiphyseal scar and if used in the nonvalgus tibia. When seating of the tibial guide rod is incomplete or when the tibia has a valgus anatomic bow, cross-checking with extramedullary alignment devices is recommended to maximize accuracy of tibial component position.

Mesh:

Year:  1995        PMID: 7866803

Source DB:  PubMed          Journal:  Am J Knee Surg        ISSN: 0899-7403


  7 in total

1.  The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

Authors:  Hyuk-Soo Han; Seung-Baik Kang; Chris H Jo; Sun-Hong Kim; Jung-Ha Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-08       Impact factor: 4.342

2.  Cutting errors in total knee replacement: assessment by computer assisted surgery.

Authors:  W P Yau; K Y Chiu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-05-14       Impact factor: 4.342

3.  Reliable and reproducible technique to mark center of ankle in total knee arthroplasty.

Authors:  Anshul Sobti; Shriji Maniar; Sameer Chaudhari; Vivek Shetty
Journal:  J Clin Orthop Trauma       Date:  2015-03-19

4.  Evaluation of lower limb axial alignment using digital radiography stitched films in pre-operative planning for total knee replacement.

Authors:  Michael J Neil; Jereme B Atupan; Juan Paulo L Panti; Robert A J Massera; Stewart Howard
Journal:  J Orthop       Date:  2016-06-29

5.  Proximal tibial resection in varus-deformed tibiae during total knee arthroplasty: an in vitro study using sawbone model.

Authors:  Sang-Min Kim; Keun-Woo Kim; Sung-Mu Cha; Kye-Young Han
Journal:  Int Orthop       Date:  2014-08-27       Impact factor: 3.075

6.  Significant Incidence of Extra-Articular Tibia Vara Affects Radiological Outcome of Total Knee Arthroplasty.

Authors:  Balaji Saibaba; Mandeep S Dhillon; Devendra K Chouhan; Rajendra K Kanojia; Mahesh Prakash; Vikas Bachhal
Journal:  Knee Surg Relat Res       Date:  2015-09-01

7.  Effects of tibial torsion on distal alignment of extramedullary instrumentation in total knee arthroplasty.

Authors:  Gianluca Cinotti; Pasquale Sessa; Antonello Della Rocca; Francesca Romana Ripani; Giuseppe Giannicola
Journal:  Acta Orthop       Date:  2013-04-17       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.