Accuracy of intramedullary alignment in total knee replacement.

M A Elloy1, M P Manning, R Johnson.   

Abstract

The accuracy of a system of intramedullary alignment using 6 mm rods was assessed in 100 patients undergoing total knee replacements. Post-operative, full length weight-bearing X-rays were used; the mechanical axis from head was used as the reference axis. The method of calculating the errors produced by flexion and rotation of the limb in relation to the X-ray beam is described, the mean deviation from the mechanical axis in 100 cases being 0.67 degrees valgus with a standard deviation of 2.47 degrees. The maximum error was 6.68 degrees valgus and 4.62 degrees varus. The purpose of this study is twofold, first to assess the accuracy of this system of intramedullary alignment and, second, to develop a method of correcting for apparent radiological misalignment using standard radiographic equipment.

Entities:  

Mesh:

Year:  1992        PMID: 1405552     DOI: 10.1016/0141-5425(92)90080-5

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  10 in total

1.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

2.  Total knee arthroplasty implanted with and without kinematic navigation.

Authors:  R Hart; M Janecek; A Chaker; P Bucek
Journal:  Int Orthop       Date:  2003-08-26       Impact factor: 3.075

3.  Cutting errors in total knee replacement: assessment by computer assisted surgery.

Authors:  W P Yau; K Y Chiu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-05-14       Impact factor: 4.342

Review 4.  [Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies].

Authors:  H Bäthis; S Shafizadeh; T Paffrath; C Simanski; J Grifka; C Lüring
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

5.  Varus gonarthrosis predisposes to varus malalignment in TKA.

Authors:  Thomas J Heyse; Ralf Decking; Jack Davis; Friedrich Boettner; Richard S Laskin
Journal:  HSS J       Date:  2009-05-20

6.  Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

Authors:  Günther Maderbacher; Jan Matussek; Armin Keshmiri; Felix Greimel; Clemens Baier; Joachim Grifka; Hermann Maderbacher
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-02-17       Impact factor: 4.342

7.  Radiological assessment of the femoral bowing in Japanese population.

Authors:  Ahmed Hamed Kassem Abdelaal; Norio Yamamoto; Katsuhiro Hayashi; Akihiko Takeuchi; Ahmad Fawaz Morsy; Shinji Miwa; Yoshitomo Kajino; Donnel A Rubio; Hiroyuki Tsuchiya
Journal:  SICOT J       Date:  2016-01-22

8.  The use of imageless navigation to quantify cutting error in total knee arthroplasty.

Authors:  Ran Schwarzkopf; Morteza Meftah; Scott E Marwin; Michelle A Zabat; Jeffrey M Muir; Iain R Lamb
Journal:  Knee Surg Relat Res       Date:  2021-12-04

9.  Significant Incidence of Extra-Articular Tibia Vara Affects Radiological Outcome of Total Knee Arthroplasty.

Authors:  Balaji Saibaba; Mandeep S Dhillon; Devendra K Chouhan; Rajendra K Kanojia; Mahesh Prakash; Vikas Bachhal
Journal:  Knee Surg Relat Res       Date:  2015-09-01

10.  Accurate implant fit and leg alignment after cruciate-retaining patient-specific total knee arthroplasty.

Authors:  Jörg Arnholdt; Yama Kamawal; Konstantin Horas; Boris M Holzapfel; Fabian Gilbert; Axel Ripp; Maximilian Rudert; Andre F Steinert
Journal:  BMC Musculoskelet Disord       Date:  2020-10-22       Impact factor: 2.362

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.