Literature DB >> 18460750

A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring.

Byungchul Cho1, Yelin Suh, Sonja Dieterich, Paul J Keall.   

Abstract

Three major linear accelerator vendors offer gantry-mounted single (monoscopic) x-ray imagers. The use of monoscopic imaging to estimate three-dimensional (3D) target positions has not been fully explored. The purpose of this work is to develop and investigate a robust monoscopic method for real-time tumour tracking, combining occasional x-ray imaging and continuous external respiratory monitoring, and compare this with an established stereoscopic method. Monoscopic estimation of 3D target positions is a two-step procedure. Step (1) is similar to the stereoscopic approach using combined occasional x-ray imaging and real-time external respiratory monitoring, i.e. to establish the correlation between the target coordinates T(x, y, z) and the external respiratory signal (R) (sECM: stereoscopic external correlation model). However, in monoscopic estimation, the correlation between the two coordinates (xp, yp) projected on the imager plane and the external respiratory signal (mECM: monoscopic external correlation model) is established. With only a single projection, the component of the 3D target position, which is along the x-ray imaging direction, is unresolved. Therefore, step (2) is used to estimate the unresolved component (z( parallel)) by building a correlation model between the unresolved component and the two other components projected on the imager (ICM: internal correlation model) with a prior 3D target trajectory that may be obtained by 4DCT, MV/kV imaging or 4DCBCT. At the time of prediction, (xp, yp) are estimated from (R) using the correlation model in step (1), and then z( parallel) is estimated from the estimated (xp, yp) using the correlation model in step (2). The performance of the proposed method was evaluated under various model update intervals and compared with the stereoscopic estimation method using 160 tumour trajectory and external respiratory motion data recorded at 25 Hz from 46 thoracic and abdominal cancer patients who underwent hypofractionated stereotactic radiotherapy by a CyberKnife system. The precision of the input data used in this study to represent tumour motion was assessed using x-ray imaging to be 1.5 +/- 0.8 mm. Monoscopic imaging every 30/60 s with updating ICM every 120/180 s can estimate target positions with a 1 mm root-mean-square error (RMSE) for 63/53% or a 2 mm RMSE for 93/91%, respectively. In contrast, stereoscopic x-ray imaging every 30/60 s can estimate target motion within a 1 mm RMSE for 72/58% or a 2 mm RMSE for 95/92%, respectively. The overall 3D error of the monoscopic estimation is approximately 10% higher than comparable stereoscopic imaging methods when the period between imaging is 1 s or more, and 40% higher for continuous imaging. The promising result may be explained by the fact that superior/inferior motion-the major axis of tumour motion-is fully resolved even in the monoscopic view for coplanar treatments, and tumour motion in each dimension is relatively well correlated.

Entities:  

Mesh:

Year:  2008        PMID: 18460750     DOI: 10.1088/0031-9155/53/11/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Correlation and prediction uncertainties in the cyberknife synchrony respiratory tracking system.

Authors:  Eric W Pepin; Huanmei Wu; Yuenian Zhang; Bryce Lord
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

2.  A Bayesian approach to real-time 3D tumor localization via monoscopic x-ray imaging during treatment delivery.

Authors:  Ruijiang Li; Benjamin P Fahimian; Lei Xing
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID.

Authors:  Inhwan Jason Yeo; Jae Won Jung; Byong Yong Yi; Jong Oh Kim
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

4.  Real-time tumor tracking using sequential kV imaging combined with respiratory monitoring: a general framework applicable to commonly used IGRT systems.

Authors:  Byungchul Cho; Per Rugaard Poulsen; Paul J Keall
Journal:  Phys Med Biol       Date:  2010-05-18       Impact factor: 3.609

5.  Real-time target position estimation using stereoscopic kilovoltage/megavoltage imaging and external respiratory monitoring for dynamic multileaf collimator tracking.

Authors:  Byungchul Cho; Per Rugaard Poulsen; Amit Sawant; Dan Ruan; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-07-07       Impact factor: 7.038

6.  Correlation between external and internal respiratory motion: a validation study.

Authors:  Floris Ernst; Ralf Bruder; Alexander Schlaefer; Achim Schweikard
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-08-19       Impact factor: 2.924

Review 7.  Review of Real-Time 3-Dimensional Image Guided Radiation Therapy on Standard-Equipped Cancer Radiation Therapy Systems: Are We at the Tipping Point for the Era of Real-Time Radiation Therapy?

Authors:  Paul J Keall; Doan Trang Nguyen; Ricky O'Brien; Pengpeng Zhang; Laura Happersett; Jenny Bertholet; Per R Poulsen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-04-14       Impact factor: 7.038

8.  Efficient implementation of the rank correlation merit function for 2D/3D registration.

Authors:  M Figl; C Bloch; C Gendrin; C Weber; S A Pawiro; J Hummel; P Markelj; F Pernus; H Bergmann; W Birkfellner
Journal:  Phys Med Biol       Date:  2010-09-16       Impact factor: 3.609

9.  Experimental investigation of a general real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring.

Authors:  Byungchul Cho; Per Poulsen; Dan Ruan; Amit Sawant; Paul J Keall
Journal:  Phys Med Biol       Date:  2012-10-24       Impact factor: 3.609

10.  Monitoring tumor motion by real time 2D/3D registration during radiotherapy.

Authors:  Christelle Gendrin; Hugo Furtado; Christoph Weber; Christoph Bloch; Michael Figl; Supriyanto Ardjo Pawiro; Helmar Bergmann; Markus Stock; Gabor Fichtinger; Dietmar Georg; Wolfgang Birkfellner
Journal:  Radiother Oncol       Date:  2011-08-30       Impact factor: 6.280

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.