Literature DB >> 21853246

Correlation between external and internal respiratory motion: a validation study.

Floris Ernst1, Ralf Bruder, Alexander Schlaefer, Achim Schweikard.   

Abstract

PURPOSE: In motion-compensated image-guided radiotherapy, accurate tracking of the target region is required. This tracking process includes building a correlation model between external surrogate motion and the motion of the target region. A novel correlation method is presented and compared with the commonly used polynomial model. METHODS AND MATERIALS: The CyberKnife system (Accuray, Inc., Sunnyvale/CA) uses a polynomial correlation model to relate externally measured surrogate data (optical fibres on the patient's chest emitting red light) to infrequently acquired internal measurements (X-ray data). A new correlation algorithm based on ɛ -Support Vector Regression (SVR) was developed. Validation and comparison testing were done with human volunteers using live 3D ultrasound and externally measured infrared light-emitting diodes (IR LEDs). Seven data sets (5:03-6:27 min long) were recorded from six volunteers.
RESULTS: Polynomial correlation algorithms were compared to the SVR-based algorithm demonstrating an average increase in root mean square (RMS) accuracy of 21.3% (0.4 mm). For three signals, the increase was more than 29% and for one signal as much as 45.6% (corresponding to more than 1.5 mm RMS). Further analysis showed the improvement to be statistically significant.
CONCLUSION: The new SVR-based correlation method outperforms traditional polynomial correlation methods for motion tracking. This method is suitable for clinical implementation and may improve the overall accuracy of targeted radiotherapy.

Entities:  

Mesh:

Year:  2011        PMID: 21853246     DOI: 10.1007/s11548-011-0653-6

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  17 in total

1.  Correlating chest surface motion to motion of the liver using epsilon-SVR--a porcine study.

Authors:  Floris Ernst; Volker Martens; Stefan Schlichting; Armin Besirević; Markus Kleemann; Christoph Koch; Dirk Petersen; Achim Schweikard
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

2.  The correlation between internal and external markers for abdominal tumors: implications for respiratory gating.

Authors:  David P Gierga; Johanna Brewer; Gregory C Sharp; Margrit Betke; Christopher G Willett; George T Y Chen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-04-01       Impact factor: 7.038

3.  Novel breathing motion model for radiotherapy.

Authors:  Daniel A Low; Parag J Parikh; Wei Lu; James F Dempsey; Sasha H Wahab; James P Hubenschmidt; Michelle M Nystrom; Maureen Handoko; Jeffrey D Bradley
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-11-01       Impact factor: 7.038

4.  Derivation of the tumor position from external respiratory surrogates with periodical updating of the internal/external correlation.

Authors:  E Kanoulas; J A Aslam; G C Sharp; R I Berbeco; S Nishioka; H Shirato; S B Jiang
Journal:  Phys Med Biol       Date:  2007-08-21       Impact factor: 3.609

5.  Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors.

Authors:  Ross I Berbeco; Steve B Jiang; Gregory C Sharp; George T Chen; Hassan Mostafavi; Hiroki Shirato
Journal:  Phys Med Biol       Date:  2004-01-21       Impact factor: 3.609

6.  Accuracy in the localization of thoracic and abdominal tumors using respiratory displacement, velocity, and phase.

Authors:  U W Langner; P J Keall
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

7.  Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker.

Authors:  S S Vedam; V R Kini; P J Keall; V Ramakrishnan; H Mostafavi; R Mohan
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

8.  A feasibility study on the prediction of tumour location in the lung from skin motion.

Authors:  S Ahn; B Yi; Y Suh; J Kim; S Lee; S Shin; S Shin; E Choi
Journal:  Br J Radiol       Date:  2004-07       Impact factor: 3.039

9.  A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring.

Authors:  Byungchul Cho; Yelin Suh; Sonja Dieterich; Paul J Keall
Journal:  Phys Med Biol       Date:  2008-05-06       Impact factor: 3.609

10.  Respiration tracking in radiosurgery.

Authors:  Achim Schweikard; Hiroya Shiomi; John Adler
Journal:  Med Phys       Date:  2004-10       Impact factor: 4.071

View more
  11 in total

1.  Fast and robust extraction of surrogate respiratory signal from intra-operative liver ultrasound images.

Authors:  Jiaze Wu; Cheng Li; Su Huang; Feng Liu; Bien Soo Tan; London Lucien Ooi; Haoyong Yu; Jimin Liu
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-06-08       Impact factor: 2.924

2.  Feasibility of respiratory motion-compensated stereoscopic X-ray tracking for bronchoscopy.

Authors:  Nikolas Leßmann; Daniel Drömann; Alexander Schlaefer
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-26       Impact factor: 2.924

3.  Assessment of patient selection criteria for quantitative imaging with respiratory-gated positron emission tomography.

Authors:  Stephen R Bowen; Larry A Pierce; Adam M Alessio; Chi Liu; Scott D Wollenweber; Charles W Stearns; Paul E Kinahan
Journal:  J Med Imaging (Bellingham)       Date:  2014-09-24

4.  Subject-specific real-time respiratory liver motion compensation method for ultrasound-MRI/CT fusion imaging.

Authors:  Minglei Yang; Hui Ding; Jingang Kang; Lei Zhu; Guangzhi Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-14       Impact factor: 2.924

5.  Characterization of optical-surface-imaging-based spirometry for respiratory surrogating in radiotherapy.

Authors:  Guang Li; Jie Wei; Hailiang Huang; Qing Chen; Carl P Gaebler; Tiffany Lin; Amy Yuan; Andreas Rimner; James Mechalakos
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

6.  Real-time liver tracking algorithm based on LSTM and SVR networks for use in surface-guided radiation therapy.

Authors:  Guangyu Wang; Zhibin Li; Guangjun Li; Guyu Dai; Qing Xiao; Long Bai; Yisong He; Yaxin Liu; Sen Bai
Journal:  Radiat Oncol       Date:  2021-01-14       Impact factor: 3.481

7.  Development of AI-driven prediction models to realize real-time tumor tracking during radiotherapy.

Authors:  Dejun Zhou; Mitsuhiro Nakamura; Nobutaka Mukumoto; Hiroaki Tanabe; Yusuke Iizuka; Michio Yoshimura; Masaki Kokubo; Yukinori Matsuo; Takashi Mizowaki
Journal:  Radiat Oncol       Date:  2022-02-23       Impact factor: 3.481

8.  Challenges and opportunities in patient-specific, motion-managed and PET/CT-guided radiation therapy of lung cancer: review and perspective.

Authors:  Stephen R Bowen; Matthew J Nyflot; Michael Gensheimer; Kristi R G Hendrickson; Paul E Kinahan; George A Sandison; Shilpen A Patel
Journal:  Clin Transl Med       Date:  2012-08-31

9.  Nearest Neighbor Method to Estimate Internal Target for Real-Time Tumor Tracking.

Authors:  Jie Zhang; Xiaolin Huang; Yuxiaotong Shen; Ying Chen; Jing Cai; Yun Ge
Journal:  Technol Cancer Res Treat       Date:  2018-01-01

10.  Concept for Markerless 6D Tracking Employing Volumetric Optical Coherence Tomography.

Authors:  Matthias Schlüter; Lukas Glandorf; Martin Gromniak; Thore Saathoff; Alexander Schlaefer
Journal:  Sensors (Basel)       Date:  2020-05-08       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.