Literature DB >> 18443787

Musculoskeletal applications of flat-panel volume CT.

Benjamin Reichardt1, Ammar Sarwar, Soenke H Bartling, Arnold Cheung, Michael Grasruck, Christianne Leidecker, Miriam A Bredella, Thomas J Brady, Rajiv Gupta.   

Abstract

Flat-panel volume computed tomography (fpVCT) is a recent development in imaging. We discuss some of the musculoskeletal applications of a high-resolution flat-panel CT scanner. FpVCT has four main advantages over conventional multidetector computed tomography (MDCT): high-resolution imaging; volumetric coverage; dynamic imaging; omni-scanning. The overall effective dose of fpVCT is comparable to that of MDCT scanning. Although current fpVCT technology has higher spatial resolution, its contrast resolution is slightly lower than that of MDCT (5-10HU vs. 1-3HU respectively). We discuss the efficacy and potential utility of fpVCT in various applications related to musculoskeletal radiology and review some novel applications for pediatric bones, soft tissues, tumor perfusion, and imaging of tissue-engineered bone growth. We further discuss high-resolution CT and omni-scanning (combines fluoroscopic and tomographic imaging).

Entities:  

Mesh:

Year:  2008        PMID: 18443787     DOI: 10.1007/s00256-008-0473-0

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  23 in total

1.  High-resolution MRI vs multislice spiral CT: which technique depicts the trabecular bone structure best?

Authors:  Thomas M Link; Volker Vieth; Christoph Stehling; Albrecht Lotter; Ambros Beer; David Newitt; Sharmila Majumdar
Journal:  Eur Radiol       Date:  2002-09-27       Impact factor: 5.315

2.  Low-contrast detectability in volume rendering: a phantom study on multidetector-row spiral CT data.

Authors:  Hoen-Oh Shin; Christian V Falck; Michael Galanski
Journal:  Eur Radiol       Date:  2003-10-11       Impact factor: 5.315

3.  Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience.

Authors:  Konstantin Nikolaou; Thomas Flohr; Karl Stierstorfer; Christoph R Becker; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2004-11-20       Impact factor: 5.315

4.  Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery.

Authors:  J H Siewerdsen; D J Moseley; S Burch; S K Bisland; A Bogaards; B C Wilson; D A Jaffray
Journal:  Med Phys       Date:  2005-01       Impact factor: 4.071

5.  Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot.

Authors:  T G Flohr; K Stierstorfer; S Ulzheimer; H Bruder; A N Primak; C H McCollough
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

Review 6.  Computed tomographic angiography in stroke imaging: fundamental principles, pathologic findings, and common pitfalls.

Authors:  Rajiv Gupta; Stephen E Jones; Eline A Q Mooyaart; Stuart R Pomerantz
Journal:  Semin Ultrasound CT MR       Date:  2006-06       Impact factor: 1.875

7.  Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization.

Authors:  Rajiv Gupta; Michael Grasruck; Christoph Suess; Soenke H Bartling; Bernhard Schmidt; Karl Stierstorfer; Stefan Popescu; Tom Brady; Thomas Flohr
Journal:  Eur Radiol       Date:  2006-03-10       Impact factor: 5.315

8.  [Computerized tomography diagnosis of scaphoid fracture and pseudarthrosis in comparison with roentgen image].

Authors:  R Frahm; K Lowka; P Vineé
Journal:  Handchir Mikrochir Plast Chir       Date:  1992-03       Impact factor: 1.018

9.  The prevalence of established scaphoid fracture non-union found on incidental radiography.

Authors:  K R Sehat; G C Bannister
Journal:  Injury       Date:  2000-05       Impact factor: 2.586

10.  Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis.

Authors:  Fabian Kiessling; Susanne Greschus; Matthias P Lichy; Michael Bock; Christian Fink; Silvia Vosseler; Jens Moll; Margareta M Mueller; Norbert E Fusenig; Horst Traupe; Wolfhard Semmler
Journal:  Nat Med       Date:  2004-09-07       Impact factor: 53.440

View more
  11 in total

1.  [Flat panel technology in the orthopaedic trauma operating room].

Authors:  T Mattes
Journal:  Unfallchirurg       Date:  2012-03       Impact factor: 1.000

2.  Radiological diagnostic progress in skeletal diseases.

Authors:  Giuseppe Guglielmi; Michelangelo Nasuto; Michele La Porta
Journal:  Clin Cases Miner Bone Metab       Date:  2011-01

3.  Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT.

Authors:  Catherine M Phan; Eric A Macklin; Miriam A Bredella; Monica Dadrich; Paul Flechsig; Albert J Yoo; Joshua A Hirsch; Rajiv Gupta
Journal:  Skeletal Radiol       Date:  2010-07-25       Impact factor: 2.199

4.  Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems.

Authors:  Kwang Nam Jin; Chang Min Park; Jin Mo Goo; Hyun Ju Lee; Youkyung Lee; Jung Im Kim; So Young Choi; Hyo-Cheol Kim
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

5.  Reproducibility of trabecular structure analysis using flat-panel volume computed tomography.

Authors:  Arnold C Cheung; Miriam A Bredella; Ma'moun Al Khalaf; Michael Grasruck; Christianne Leidecker; Rajiv Gupta
Journal:  Skeletal Radiol       Date:  2009-05-09       Impact factor: 2.199

6.  High-resolution dynamic angiography using flat-panel volume CT: feasibility demonstration for neuro and lower limb vascular applications.

Authors:  Amit Mehndiratta; James D Rabinov; Michael Grasruck; Eric C Liao; David Crandell; Rajiv Gupta
Journal:  Eur Radiol       Date:  2015-02-27       Impact factor: 5.315

Review 7.  High-resolution imaging techniques for the assessment of osteoporosis.

Authors:  Roland Krug; Andrew J Burghardt; Sharmila Majumdar; Thomas M Link
Journal:  Radiol Clin North Am       Date:  2010-05       Impact factor: 2.303

8.  Measurement of the midpalatal suture width.

Authors:  Susanne Fricke-Zech; Rudolf M Gruber; Christian Dullin; Antonia Zapf; Franz-Josef Kramer; Dietmar Kubein-Meesenburg; Wolfram Hahn
Journal:  Angle Orthod       Date:  2011-08-03       Impact factor: 2.079

9.  Hormone predictors of abnormal bone microarchitecture in women with anorexia nervosa.

Authors:  Elizabeth A Lawson; Karen K Miller; Miriam A Bredella; Catherine Phan; Madhusmita Misra; Erinne Meenaghan; Lauren Rosenblum; Daniel Donoho; Rajiv Gupta; Anne Klibanski
Journal:  Bone       Date:  2009-09-09       Impact factor: 4.398

Review 10.  High-resolution computed tomography for clinical imaging of bone microarchitecture.

Authors:  Andrew J Burghardt; Thomas M Link; Sharmila Majumdar
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.