Literature DB >> 19430779

Reproducibility of trabecular structure analysis using flat-panel volume computed tomography.

Arnold C Cheung1, Miriam A Bredella, Ma'moun Al Khalaf, Michael Grasruck, Christianne Leidecker, Rajiv Gupta.   

Abstract

PURPOSE: To determine inter-scan, inter-reader and intra-reader variability of trabecular structure analysis using flat-panel volume computed tomography (fp-VCT) in cadaver knee specimens.
METHODS: Five explanted knee specimens were imaged at three different time points using fp-VCT. Four parameters that quantify trabecular bone structure of the proximal tibia were measured by two observers at two different time points. Bland-Altman analysis was used to compute the inter-scan, inter-observer and intra-observer variability.
RESULTS: Inter-scan variability was low, with a mean difference of 0% and a standard deviation less than 8.4% for each of the four parameters. The inter-observer and intra-observer variability was less than 2.8% +/- 8.5%.
CONCLUSION: Fp-VCT is a method for assessing trabecular structure parameters with low inter-scan, inter-reader and intra-reader variability.

Mesh:

Year:  2009        PMID: 19430779     DOI: 10.1007/s00256-009-0707-9

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  28 in total

1.  High-resolution MRI vs multislice spiral CT: which technique depicts the trabecular bone structure best?

Authors:  Thomas M Link; Volker Vieth; Christoph Stehling; Albrecht Lotter; Ambros Beer; David Newitt; Sharmila Majumdar
Journal:  Eur Radiol       Date:  2002-09-27       Impact factor: 5.315

Review 2.  Quantitative MRI for the assessment of bone structure and function.

Authors:  Felix W Wehrli; Hee Kwon Song; Punam K Saha; Alexander C Wright
Journal:  NMR Biomed       Date:  2006-11       Impact factor: 4.044

3.  Changes in calcaneal trabecular bone structure assessed with high-resolution MR imaging in patients with kidney transplantation.

Authors:  T M Link; K Kisters; M Kempkes; M Kosch; D Newitt; Y Lu; S Waldt; S Majumdar
Journal:  Osteoporos Int       Date:  2002       Impact factor: 4.507

4.  Predicting human vertebral bone strength by vertebral static histomorphometry.

Authors:  J S Thomsen; E N Ebbesen; L Mosekilde
Journal:  Bone       Date:  2002-03       Impact factor: 4.398

5.  Bone histomorphometry: standardization of nomenclature, symbols and units. Summary of proposed system.

Authors:  A M Parfitt
Journal:  Bone Miner       Date:  1988-04

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 7.  Effects of osteoporosis medications on bone quality.

Authors:  Claude-Laurent Benhamou
Journal:  Joint Bone Spine       Date:  2006-11-28       Impact factor: 4.929

8.  Trabecular bone structure obtained from multislice spiral computed tomography of the calcaneus predicts osteoporotic vertebral deformities.

Authors:  Priyesh V Patel; Sven Prevrhal; Jan S Bauer; Catherine Phan; Felix Eckstein; Eva-Maria Lochmüller; Sharmila Majumdar; Thomas M Link
Journal:  J Comput Assist Tomogr       Date:  2005 Mar-Apr       Impact factor: 1.826

9.  Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference.

Authors:  Catherine M Phan; Maiko Matsuura; Jan S Bauer; Timothy C Dunn; David Newitt; Eva M Lochmueller; Felix Eckstein; Sharmila Majumdar; Thomas M Link
Journal:  Radiology       Date:  2006-03-28       Impact factor: 11.105

10.  Reproducibility and error sources of micro-MRI-based trabecular bone structural parameters of the distal radius and tibia.

Authors:  B R Gomberg; F W Wehrli; B Vasilić; R H Weening; P K Saha; H K Song; A C Wright
Journal:  Bone       Date:  2004-07       Impact factor: 4.398

View more
  6 in total

1.  Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT.

Authors:  Catherine M Phan; Eric A Macklin; Miriam A Bredella; Monica Dadrich; Paul Flechsig; Albert J Yoo; Joshua A Hirsch; Rajiv Gupta
Journal:  Skeletal Radiol       Date:  2010-07-25       Impact factor: 2.199

2.  Locally measured microstructural parameters are better associated with vertebral strength than whole bone density.

Authors:  J Hazrati Marangalou; F Eckstein; V Kuhn; K Ito; M Cataldi; F Taddei; B van Rietbergen
Journal:  Osteoporos Int       Date:  2013-12-04       Impact factor: 4.507

3.  Report on the special scientific session held at the ISS Congress, Athens, Greece, 2010.

Authors:  Andrew J Grainger
Journal:  Skeletal Radiol       Date:  2011-08       Impact factor: 2.199

4.  High-resolution dynamic angiography using flat-panel volume CT: feasibility demonstration for neuro and lower limb vascular applications.

Authors:  Amit Mehndiratta; James D Rabinov; Michael Grasruck; Eric C Liao; David Crandell; Rajiv Gupta
Journal:  Eur Radiol       Date:  2015-02-27       Impact factor: 5.315

5.  Measurement of the midpalatal suture width.

Authors:  Susanne Fricke-Zech; Rudolf M Gruber; Christian Dullin; Antonia Zapf; Franz-Josef Kramer; Dietmar Kubein-Meesenburg; Wolfram Hahn
Journal:  Angle Orthod       Date:  2011-08-03       Impact factor: 2.079

6.  C-arm CT for histomorphometric evaluation of lumbar spine trabecular microarchitecture: a study on anorexia nervosa patients.

Authors:  C M Phan; O Khalilzadeh; J Dinkel; I S Wang; M A Bredella; M Misra; K K Miller; A Klibanski; R Gupta
Journal:  Br J Radiol       Date:  2013-05-02       Impact factor: 3.039

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.