Literature DB >> 16279080

A system for real-time XMR guided cardiovascular intervention.

Kawal S Rhode1, Maxime Sermesant, David Brogan, Sanjeet Hegde, John Hipwell, Pier Lambiase, Eric Rosenthal, Clifford Bucknall, Shakeel A Qureshi, Jaswinder S Gill, Reza Razavi, Derek L G Hill.   

Abstract

The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sliding table XMR configuration. The aim of our recent work was to extend our technique by providing an improved calibration stage, real-time guidance during cardiovascular catheterization procedures, and further off-line analysis for mapping cardiac electrical data to patient anatomy. Specially designed optical trackers and a dedicated calibration object have resulted in a single calibration step that can be efficiently checked and updated before each procedure. An X-ray distortion model has been implemented that allows for distortion correction for arbitrary c-arm orientations. During procedures, the guidance system provides a real-time combined MR/X-ray image display consisting of live X-ray images with registered recently acquired MR derived anatomy. It is also possible to reconstruct the location of catheters seen during X-ray imaging in the MR derived patient anatomy. We have applied our registration technique to 13 cardiovascular catheterization procedures. Our system has been used for the real-time guidance of ten radiofrequency ablations and one aortic stent implantation. We demonstrate the real-time guidance using two exemplar cases. In a further two cases we show how off-line analysis of registered image data, acquired during electrophysiology study procedures, has been used to map cardiac electrical measurements to patient anatomy for two different types of mapping catheters. The cardiologists that have used the guidance system suggest that real-time XMR guidance could have substantial value in difficult interventional and electrophysiological procedures, potentially reducing procedure time and delivered radiation dose. Also, the ability to map measured electrical data to patient specific anatomy provides improved visualization and a path to investigation of cardiac electromechanical models.

Entities:  

Mesh:

Year:  2005        PMID: 16279080     DOI: 10.1109/TMI.2005.856731

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  25 in total

1.  High-resolution 3D arteriography of chronic total peripheral occlusions using a T1-W turbo spin-echo sequence with inner-volume imaging.

Authors:  Smita Sampath; Amish N Raval; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

2.  Technology preview: X-ray fused with magnetic resonance during invasive cardiovascular procedures.

Authors:  Luis F Gutiérrez; Ranil de Silva; Cengizhan Ozturk; Merdim Sonmez; Annette M Stine; Amish N Raval; Venkatesh K Raman; Vandana Sachdev; Ronnier J Aviles; Myron A Waclawiw; Elliot R McVeigh; Robert J Lederman
Journal:  Catheter Cardiovasc Interv       Date:  2007-11-15       Impact factor: 2.692

Review 3.  Advances in interventional neuroimaging.

Authors:  Vallabh Janardhan; Adnan I Qureshi
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

4.  A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system.

Authors:  Luis F Gutiérrez; Cengizhan Ozturk; Elliot R McVeigh; Robert J Lederman
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

5.  Closed bore XMR (CBXMR) systems for aortic valve replacement: investigation of rotating-anode x-ray tube heat loadability.

Authors:  John A Bracken; Prasheel V Lillaney; Rebecca Fahrig; J A Rowlands
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

Review 6.  Cardiac magnetic resonance imaging and computed tomography: anatomic fundamentals.

Authors:  Jasbir S Sra
Journal:  J Interv Card Electrophysiol       Date:  2011-04-05       Impact factor: 1.900

7.  Robust automatic rigid registration of MRI and X-ray using external fiducial markers for XFM-guided interventional procedures.

Authors:  Ashvin K George; Merdim Sonmez; Robert J Lederman; Anthony Z Faranesh
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

8.  Integration of cardiac and respiratory motion into MRI roadmaps fused with x-ray.

Authors:  Anthony Z Faranesh; Peter Kellman; Kanishka Ratnayaka; Robert J Lederman
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

9.  Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.

Authors:  Ehud J Schmidt; Zion T H Tse; Tobias R Reichlin; Gregory F Michaud; Ronald D Watkins; Kim Butts-Pauly; Raymond Y Kwong; William Stevenson; Jeffrey Schweitzer; Israel Byrd; Charles L Dumoulin
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

Review 10.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.