Correction for geometric image distortion in the x-ray imaging chain: local technique versus global technique.

E Gronenschild1.   

Abstract

The local technique to correct for geometric image distortion in the x-ray imaging chain has been implemented and compared with the global correction technique reported previously. Three local correction models were considered, all applied locally within each quadrilateral cell bounded by four adjacent points on a distorted 1.0 cm spaced rectilinear calibration grid. Model 1 uses bilinear interpolation between the correction vectors derived at the four vertices. In Models 2 and 3 a polynomial mapping from distorted to undistorted positions is applied, with Model 2 representing a linear six-parameter correction and Model 3 a nonlinear eight-parameter correction. Both techniques have been analyzed in depth concerning their accuracy. To this end, experimental (35 mm cine film and online video) and computer simulated distorted images of the calibration grid were used. Both radial and sigmoidal distortions were considered in the simulations. The main results are summarized as follows. The accuracy of the local technique depends upon the position within each quadrilateral cell and upon the local direction of the distortion gradient, contrary to the global technique. The accuracy of the local technique decreases with increasing radial as well as sigmoidal distortion. For the global technique only the latter dependency applies. The relationship of the accuracy with the pixel size is different for all models. Finally, the local technique is more sensitive to noise than the global technique. The reproducibility of the correction methods has been evaluated by means of imaging the calibration grid in various orientations with respect to the input screen of the image intensifier. The local technique turns out to reproduce a factor of 4-10 worse than the global technique. In summary, Model 1 is the worst method in all respects, whereas Model 3 is slightly better than Model 2. However, the global technique is to be preferred because it outperforms the local technique on all relevant issues.

Entities:  

Mesh:

Year:  1999        PMID: 10619246     DOI: 10.1118/1.598800

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system.

Authors:  Luis F Gutiérrez; Cengizhan Ozturk; Elliot R McVeigh; Robert J Lederman
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

2.  Geometric calibration and correction for a lens-coupled detector in x-ray phase-contrast imaging.

Authors:  Alex George; Peter Y Chen; Alejandro Morales-Martinez; Alireza Panna; Andrew A Gomella; Eric E Bennett; Han Wen
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-24

3.  Influence of multi-angle input of intraoperative fluoroscopic images on the spatial positioning accuracy of the C-arm calibration-based algorithm of a CAOS system.

Authors:  Xiangqian Chen; Yu Wang; Gang Zhu; Weijun Zhang; Gang Zhou; Yubo Fan
Journal:  Med Biol Eng Comput       Date:  2020-01-09       Impact factor: 2.602

4.  Hierarchical radial basis function networks and local polynomial un-warping for X-ray image intensifier distortion correction: a comparison with global techniques.

Authors:  P Cerveri; C Forlani; A Pedotti; G Ferrigno
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

5.  Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment.

Authors:  Angela E Kedgley; Anne-Marie V Fox; Thomas R Jenkyn
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

6.  Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait.

Authors:  Jing-Sheng Li; Tsung-Yuan Tsai; David T Felson; Guoan Li; Cara L Lewis
Journal:  PLoS One       Date:  2017-03-24       Impact factor: 3.240

7.  Effects of Barefoot and Shod on the In Vivo Kinematics of Medial Longitudinal Arch During Running Based on a High-Speed Dual Fluoroscopic Imaging System.

Authors:  Wanyan Su; Shen Zhang; Dongqiang Ye; Xiaole Sun; Xini Zhang; Weijie Fu
Journal:  Front Bioeng Biotechnol       Date:  2022-06-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.